Installation manual: Oasis security system JA-80K - 5 - MKE51801
Communicator connector – allows the connection of an
optional communicator to the main board.
Internal wiring connector – connects the internal wiring in the
control panel housing.
Terminals:
AC 20V the transformer output is connected here.
01, GND, 02 are hard-wired inputs for the control panel.
The reactions to triggering these inputs are determined by the
settings of addresses 01 and 02. The factory-set natural
reaction for these hard-wired inputs is a delayed alarm in
section C.
Terminals 01 and 02 use resistors in connected double
balanced loops to sense loop stand-by, activation or
tampering as follows:
o Connected to GND via a 1 kΩ resistor = untriggered input
o Connected to GND via 2 to 6 kΩ = triggered input,
o Connected to GND via less then 700Ω or more then 6 kΩ
= tamper signal
o Stand-by (untriggered) input zone must have 1 kΩ
o Up to five normally-closed door/window contacts can be
connected in series to enable one hard-wired input to be
used for multiple contacts with each contact having a 1kΩ
resistor in parallel (see the diagram below).
o Multiple normally-closed tamper contacts should be
connected in series without any parallel resistors. The
number of tamper contacts is unlimited and can be
combined with trigger contacts having parallel resistors (see
the diagram below).
o For wiring examples, see the below diagram.
o If you enroll a wireless device to address 01 or 02, the
corresponding input terminal will be disabled.
o If you do not use an input terminal and you do not enroll a
wireless device to its address, then the terminal must be
connected to the GND terminal via a 1 kΩ resistor.
NC normally closed contact for the external warning relay.
NO - normally open contact for the external warning relay.
EWC – common contact for the external warning relay max.
relay contact rating: 1A/60V. The control panel also transmits
the external warning relay signal via radio for wireless sirens.
IW – internal warning (siren) output. This output is grounded
during an internal alarm. A standard siren can be wired between
terminals +U and IW (max. 0.5A).
The IW output status is also
transmitted by radio for the IW siren.
The main difference between internal and external warning is during
the entrance delay period. If any instant detectors are triggered during
the entrance delay period, e.g. a child running straight to the living
room, only an internal warning will be triggered and an external
warning will only follow if the entrance delay has been exceeded.
PGX, PGY – are a pair of terminals providing programmable
outputs. If an output is activated it switches to GND with a
maximum load of 0.1A/12V. The factory-default setting of PGX is
the function ON/OFF which can be operated from the keypad by
the instruction 81 / 80 or using keys
). The factory-default
function of PGY is that it will be activated if any section of the
system is set. The status of PG outputs is also transmitted by
radio for AC and UC output modules.
GND – common ground connection
A,B – digital bus data
+U – back-up power supply (10 to 14V), 1A fuse. Max.
continuous load 0.4 A (max. intermittent load 1 A, for 15
minutes, once an hour). If the 1A fuse is blown, the control panel
will indicate power supply fault.
5. Wired keypad connection
GND A B U+
IN
+U
B
A
GND
GND
control and programming
keypad JA-80E
modular connection
cable
The control panel can be operated and programmed by JA-
80F wireless keypads and/or a JA-80E hard-wired keypad. A
hard-wired keypad can be connected to the control panel either
by flat telephone cable (max. length 10 metres) using RJ
connectors, or via twisted-pair cable (max. length 100 metres)
connected to the digital bus terminals (GND, A, B, +U).
We recommend only having a single JA-80E hard-wired
keypad in the system.
6. Back-up battery
It is possible to use a Jablotron-brand 12V back-up battery in
the control panel with capacities of 1.3Ah or 2.6no Ah. The
capacity to use depends on the total power consumption of the
system and the desired back-up period.
Euro-standard EN 50131-1 specifies a 12 hour minimum back-
up time for grade 2 systems. The standby consumption of all
system devices is shown in table 1.
Table 1- standby consumption of system devices
With a 1.3Ah back-up battery 12 hours of back-up time can be realised if
current consumption does not exceed 85mA. With 2.2Ah batteries
150mA should not be exceeded to achieve the same. This only takes
80% of the battery capacity into account as 20% has to be reserved for
battery aging effects.
The average back-up battery lifetime is up to 5 years after which it must
be replaced. The back-up battery is automatically charged and its
condition is monitored by the system. If the system is being run on only
the back-up battery a technical alarm occurs when the battery is
nearly discharged. If the voltage gets too low the battery will be
Device mA Note
Control panel JA-80K 50 No communicator
Keypad JA-80E 30
Keypad JA-80H (N) 60 Including a WJ-80 interface
Communicator JA-80Y 35
Communicator JA-80V 30
Wireless devices are not powered from the control panel.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron JA-80K bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron JA-80K in de taal/talen: Engels als bijlage per email.

De handleiding is 0,55 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Jablotron JA-80K

Jablotron JA-80K Gebruiksaanwijzing - English - 1 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info