Digital communicator JA-65X 5/7 MFM53102
Note: Changing of a phone number erases the internal
communicator’s memory of non reported events and sends a
“Reset“ reporting code (051) to the Monitoring Station.
Factory setting: both numbers are erased
4.6 Digital communicator reset
sequence: 096060
By entering this code the factory default settings of all parameters
are restored in the digital dialer. All phone numbers, reporting
codes, account codes etc. are erased. This reset doesn’t effect
the voice dialer’s settings. The reset sequence is: 0 9 6060
Note: All communicator settings are stored in non-volatile memory
and remain unchanged even after switching off the power supply.
5 Central Monitoring station report
codes table
A two digit report code rc (00 to FFh) can be set for every event.
If 00 is programmed as a report code, that event will not be
reported.
The major events group is marked by Rc. When formats 3/1 or
4/1/1 are used, only 16 of these major events are reported to
the Monitoring Station. This makes it necessary to only
program the R digits. The second digit does not count. Zero
can not be used in the pulse protocols. For Contact ID
protocol, program code 11 for major events (Rc) which you
want to report and the system will generate all details
regarding the event automatically including the events source
details (see part 5.1).
N. Event Code
001
A
rming with remote control N.1 Rc
002
A
rming with remote control N.2 Rc
003
A
rming with remote control N.3 Rc
004
A
rming with remote control N.4 Rc
005
A
rming with remote control N.5 Rc
006
A
rming with remote control N.6 Rc
007
A
rming with remote control N.7 Rc
008
A
rming with remote control N.8 Rc
009
A
rming with master code Rc
010
A
rming with user code N.1 Rc
011
A
rming with user code N.2 Rc
012
A
rming with user code N.3 Rc
013
A
rming with user code N.4 Rc
014
A
rming with user code N.5 Rc
015
A
rming with user code N.6 Rc
016
A
rming with user code N.7 Rc
017
A
rming with user code N.8 Rc
018
A
rming with user code N.9 Rc
019
A
rming with user code N.10 Rc
020
A
rming with user code N.11 Rc
021
A
rming with user code N.12 Rc
022
A
rming with user code N.13 Rc
023
A
rming with user code N.14 Rc
024 Partial arming Rc
025 Quick arming without code Rc
026 Disarming with remote control N.1 Rc
027 Disarming with remote control N.2 Rc
028 Disarming with remote control N.3 Rc
029 Disarming with remote control N.4 rc
030 Disarming with remote control N.5 rc
031 Disarming with remote control N.6 rc
032 Disarming with remote control N.7 rc
033 Disarming with remote control N.8 rc
034 Disarming with master code rc
035 Disarming with user code N.1 rc
036 Disarming with user code N.2 rc
037 Disarming with user code N.3 rc
038 Disarming with user code N.4 rc
039 Disarming with user code N.5 rc
040 Disarming with user code N.6 rc
041 Disarming with user code N.7 rc
042 Disarming with user code N.8 rc
043 Disarming with user code N.9 rc
044 Disarming with user code N.10 rc
045 Disarming with user code N.11 rc
046 Disarming with user code N.12 rc
047 Disarming with user code N.13 rc
048 Disarming with user code N.14 rc
049 Entering of the programming mode Rc
050 Exiting the programming mode Rc
051 Communicator Reset Rc
052 Initial AC powering Rc
053
larm after initial AC powering Rc
054 General battery trouble Rc
055 General battery trouble end Rc
056 Control panel battery trouble Rc
057 Control panel battery trouble end Rc
058 Zone alarm 1 Rc
059 Zone alarm 2 rc
060 Zone alarm 3 rc
061 Zone alarm 4 rc
062 Zone alarm 5 rc
063 Zone alarm 6 rc
064 Zone alarm 7 rc
065 Zone alarm 8 rc
066 Zone alarm 9 rc
067 Zone alarm 10 rc
068 Zone alarm 11 rc
069 Zone alarm 12 rc
070 Zone alarm 13 rc
071 Zone alarm 14 rc
072 Zone alarm 15 rc
073 Zone alarm 16 rc
074 Wrong access code alarm Rc
075 Zone tamper 1 Rc
076 Zone tamper 2 rc
077 Zone tamper 3 rc
078 Zone tamper 4 rc
079 Zone tamper 5 rc
080 Zone tamper 6 rc
081 Zone tamper 7 rc
082 Zone tamper 8 rc
083 Zone tamper 9 rc
084 Zone tamper 10 rc
085 Zone tamper 11 rc
086 Zone tamper 12 rc
087 Zone tamper 13 Rc
088 Zone tamper 14 Rc
089 Zone tamper 15 Rc
090 Zone tamper 16 Rc
091 Keypad tamper Rc
092 Control panel tamper Rc
093 Siren tamper Rc
094 Zone fault 1 Rc
095 Zone fault 2 Rc
096 Zone fault 3 Rc
097 Zone fault 4 Rc
098 Zone fault 5 Rc
099 Zone fault 6 Rc
100 Zone fault 7 Rc
101 Zone fault 8 Rc
102 Zone fault 9 Rc
103 Zone fault 10 Rc
104 Zone fault 11 Rc
105 Zone fault 12 Rc
106 Zone fault 13 Rc
107 Zone fault 14 Rc
108 Zone fault 15 Rc
109 Zone fault 16 Rc
110 Keypad fault Rc
111 Control panel fault Rc
112 Siren fault Rc
113 Zone alarm end 1 Rc
114 Zone alarm end 2 Rc
115 Zone alarm end 3 Rc
116 Zone alarm end 4 Rc
117 Zone alarm end 5 Rc
118 Zone alarm end 6 Rc
119 Zone alarm end 7 Rc
120 Zone alarm end 8 Rc
121 Zone alarm end 9 Rc
122 Zone alarm end 10 Rc
123 Zone alarm end 11 Rc
124 Zone alarm end 12 Rc
125 Zone alarm end 13 Rc
126 Zone alarm end 14 Rc
127 Zone alarm end 15 Rc
128 Zone alarm end 16 Rc
129 Zone tamper end 1 Rc
130 Zone tamper end 2 Rc
131 Zone tamper end 3 Rc
132 Zone tamper end 4 Rc
133 Zone tamper end 5 Rc
134 Zone tamper end 6 Rc
135 Zone tamper end 7 Rc
136 Zone tamper end 8 Rc
137 Zone tamper end 9 Rc
138 Zone tamper end 10 Rc
139 Zone tamper end 11 Rc
140 Zone tamper end 12 Rc
141 Zone tamper end 13 Rc
142 Zone tamper end 14 Rc
143 Zone tamper end 15 Rc
144 Zone tamper end 16 Rc
145 Keypad tamper end Rc
146 Control panel tamper end Rc
147 Siren tamper end Rc
148 Zone fault end 1 Rc
149 Zone fault end 2 Rc
150 Zone fault end 3 Rc
151 Zone fault end 4 Rc
152 Zone fault end 5 Rc
153 Zone fault end 6 Rc
154 Zone fault end 7 Rc
155 Zone fault end 8 Rc
156 Zone fault end 9 Rc
157 Zone fault end 10 Rc
158 Zone fault end 11 rc
159 Zone fault end 12 rc
160 Zone fault end 13 rc
161 Zone fault end 14 rc
162 Zone fault end 15 rc
163 Zone fault end 16 rc
164 Keypad fault end rc
165 Control panel fault end rc
166 Siren fault end rc
167 Telephone line trouble Rc
168 Telephone line trouble end Rc
169 Control panel failure Rc
170 End of control panel failure Rc
171 Periodic test (24 hr. from last com.) Rc
172
A
C failure (in 30 min. after failure) Rc
173
A
C failure end Rc
174 RF jamming Rc
175 Wrong code alarm end Rc
176 RF jamming end Rc
177 Panic alarm from remote control N.1 Rc
178 Panic alarm from remote control N.2 rc
179 Panic alarm from remote control N.3 rc
180 Panic alarm from remote control N.4 rc
181 Panic alarm from remote control N.5 rc
182 Panic alarm from remote control N.6 rc
183 Panic alarm from remote control N.7 rc
184 Panic alarm from remote control N.8 rc
185 Master code panic alarm rc
186 User code panic alarm rc
187 Panic alarm end from rem. contr. 1 Rc
188 Panic alarm end from rem. control N.2 rc
189 Panic alarm end from rem. control N.3 rc
190 Panic alarm end from rem. control N.4 rc
191 Panic alarm end from rem. control N.5 rc
192 Panic alarm end from rem. control N.6 rc
193 Panic alarm end from rem. control N.7 rc
194 Panic alarm end from rem. control N.8 rc
195 Master code panic alarm end rc
196 User code panic alarm end rc
197 Subsystem panic alarm Rc
198 Subsystem panic alarm end Rc
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron JA-65X bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron JA-65X in de taal/talen: Engels als bijlage per email.

De handleiding is 0,17 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info