554883
5
Verklein
Vergroot
Pagina terug
1/5
Pagina verder
GSM communicator GD-06 Allegro – complete manual 5/5 MHG 51203
Note:
Date and time in the confirmation SMS sent by GD-06 is taken from the
internal clock built-in to GD-06. This clock is set automatically by any
incoming SMS message. If the GD-06 is disconnected from power the
internal clock will be reset and it is necessary to set them again by
sending any SMS message to the GD-06.
5. Operation
5.1. Operating of outputs via SMS
Terminal must be set to OUT (see 3.2.). The output can be switched
on, switched off or switched on for adjusted period of time (PULSE).
USER (MASTER) code is required if the command SMS is sent from
phone which is not saved in the Allegro’s memory (TEL1 to TEL8).
There can be multiple commands in a single SMS but they must be
separated by comma and blank space No password is required if the
jumper is in the “NO MASTER” position. (see figure 1)
USER COMMAND PARAMETER OUTPUT
Where:
USER (MASTER) user or master code – it is not required if SMS is
received from phone number saved in positions T1 to
T8
COMMAND command (switch on, switch off, pulse)
PARAMETER only for PULSE
(1 to 99 and unit: s seconds; m minutes; h hours)
OUTPUT P1 to P6 or RELAY
Texts of command SMS after RESET EN
Index Parameters Meaning - description
100 ON To switch the output on
101 OFF to switch the output off
102 PULSE To switch the output on for adjusted period of
time
103 CREDIT To find out level of credit of pre-paid card
104 LEVEL To find out current level of GSM signal
105 CALL To get a reverse call for monitoring the area
via HF-03 set
106 STATUS To learn status of the device
107 ENABLE To enable sending of automatic reports
messages
108 DISABLE To disable sending of the automatic reports
messages (for example during installation)
109 USER User code – is used for operation from
phones which are not stored in the memory
(TEL1-TEL8)
110 MASTER Master code – is used for programming or for
operation from phones which are not stored in
the memory (TEL1-TEL8)
DINFO Information about registration code, hardware
and software version
Description of all commands is editable to simplify the operation of
Allegro (see 3.4.)
tab. 6
Examples of operating SMS:
ON P1
- Output P1 will be switched on
ON HEATER
- Output named HEATER will be switched on
USER OFF LIGHT
- Output named LIGHT will be switched off by SMS from phone, which
is not saved in Allegro (T1 to T8)
MASTER SET ON LIGHT
- Output named LIGHT will be switched on by SMS from phone, which
is not saved in Allegro (T1 to T8)
PULSE 20m P1
- Output P1 will be switched on for 20 minutes
ON HEATER, OFF LIGHT, PULSE 20m P1
- Multiple commands in one SMS
5.2. Operating of outputs by dialing-in
Outputs can be operated by phone calls from preset phone numbers
(T1 to T8). Reaction to a phone call will result in change of status (on,
off, on..) of an output or its triggering for a selected period of time.
Output must be programmed for this function by parameter NEG or INT.
Phone call must be made from phone number programmed into the
Allegro (tab.3). Multiple outputs can react independently to one phone
call, depending on their settings. The GD-06 doesn’t answer this call, so
you are not charged any telecommunication fee for this remote control.
5.3. Operating of outputs by DTMF code
It is possible to operate the outputs by DTMF code inserted when an
incoming call is answered by the Allegro. These DTMF codes must be
programmed by parameters NEG, INT and DTMF (tab.3). The phone
call will be answered within the selected time, programmed by
parameter “T” in sequence HF (4.1.). Factory default time is 10
seconds. After that Allegro is ready to receive DTMF code. Accepted
code is confirmed by a long beep. It is also important to remember that
if the phone number which is being used for entering DTMF code has
also been programmed to control an output by dial-in, then the
programmed output will be actually operated before the call can be
answered or a DTMF can be inserted.
5.4. Operating of special functions
MASTER (USER) STATUS
This command is used for checking the status of the device. The
device will send the actual status back to the sender’s number.
Communicator GD-06 reports: 1.1.04 0:00:34 Status: P1 Off, P2 Off,
P3 10.6V, P4 Off, P5 Off, P6 Off, RELAY Off, 22.5C, GSM level signal 8
MASTER (USER) CALL
- Device will make a phone call back to the number of the command
sender to activate the monitoring mode – communicate (listening)
with the area via HF-03 hands-free set. (It is necessary to have HF
set connected).
MASTER (USER) DISABLE
MASTER (USER) ENABLE
This command is used to disable or enable all automatic reports from
the system (SMS, SMS+, GPRS, voice calls). It is especially useful for
disabling of sending automatic reports during installation or servicing.
MASTER (USER) LEVEL
This command reports the strength of the GSM signal, the result will
be sent as an answer to the sender’s number.
MASTER (USER) CREDIT
An SMS containing the word CREDIT will result in sending of the
information about the actual level of credit of pre-paid card. (see 4.2.)
MASTER (USER) DINFO
Device will report to the requesting number its version of hardware
and firmware as well as its code for registration to the www server
www.gsmlink.cz.
6. Web server remote access
The setting server allows a user to read and change configuration of the
Allegro. Data transfer is made by sending an SMS or GRPS. The web
site allows:
Check current status of device
Operate the output terminals
Program all setting, which can be also set via SMS messages
Program additional features
Edit SMS texts (only if GPRS data transfer is used)
The quantity of data sent by SMS is optimized to reduce costs as
much as possible. GPRS data transfer can be used, but must be
activated on the SIM card and proper APN must be set (4.5.).
6.1. Registration to the web site
Web site www.gsmlink.cz – to register your system use the
registration code printed in the warranty certificate (the code has a form
xxxx-xxxxx-xxxx and it is a unique for each device) the registration code
can be also obtain by sending
SMS to GD-06 “MASTER
(USER) DINFO”.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron GD-06 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron GD-06 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,08 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Jablotron GD-06

Jablotron GD-06 Gebruiksaanwijzing - English - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info