JA-60GSM dialer module 9 / 11 MFJ51215
Note: The IP address can be set a similar way. For example the IP
address 192.168.1.123 on port 08080 can be set by entering 01 2 F8
129 168 001 123 8080, where F8 (#) introduces the IP address, which
must always have 12 numbers, and the port 5 numbers
.
CMS phone number erasure is possible by entering 01pF0 or 02pF0.
There will be no data transfer to a CMS if its numbers are erased.
Default setting: No phone number set
7.2 Account ID setting
A CMS uses this ID number for alarm system identification:
03 p zzzz F0
where:
zzzz is the account ID number (z = numbers from 0 to 9 or
A=F1, B=F2, C=F3, D=F4, E=F5 a F=F6)
p 1=CMS1, 2=CMS2
Default setting: ID is 0000 for both CMSs
7.3 Format setting
This sequence is used to select the communication format:
04 p x
where:
p 1=CMS1, 2=CMS2
x protocol type – see table
Protocol Type x
Contact ID DTMF 0
Jablotron SMS SMS type
1
Jablotron GPRS GPRS type
2
Default setting: Contact ID for both CMSs
7.4 Events to be reported to CMS
There are 31 types of events, which can be reported to each CMS –
see table 7.4.1. This sequence sets which events should be reported
to CMSs.
05 p uu y
where
p 1 = CMS1, 2 = CMS2
uu events index – see table 7.4.1
y 0 = report disabled, 1 = report enabled
Default setting: all reports are disabled
7.4.1 Table – complete list of events to be reported to CSM
Events index uu Events description
01 Intruder alarm – instant zone
02 Intruder alarm – delayed zone
03 Fire alarm
04 Panic alarm
05 Wrong access code alarm
06 Alarm after power on
07 Tamper alarm
08 Tamper OK
09 Alarm end
10 Alarm canceled by a user
11 Arming
12 Disarming
13 Partial arming (Home)
14 No code arming
15 External communication failure
16 External communication recovery
17 Failure
18 Failure recovery
19 AC failure longer than 30 minutes
20 AC failure
21 AC recovery
22 Battery failure
23 Battery recovery
24 Enter programming mode
25 Exit programming mode
26 Remote access
27 Remote access – end
28 RF jamming
29 Internal communication failure
30 Internal communication recovery
31 Periodic test
7.5 CMS re-dialing pause setting
If the dialer is activated it attempts to make a connection (alternating
between the primary and the backup telephone number). If it is not
possible to make a connection, a pause is initiated. After this pause
the dialer will attempt again. The pause length can be set in the
following way:
06 p t
where
t pause duration x 5 minutes (1 = 5 minutes, 2 = 10
min,..., 9 = 45 minutes)
p 1 = CMS1, 2 = CMS2
Default setting: 5 minutes for both CMSs
7.6 Interval of periodic test
The periodic test for checking the CMS link is set by activating event
No 31. The following sequence sets the time length from the last
reported event to the moment when the periodic test report should be
transferred.
07 p hhmm
where
p 1 = CMS1, 2 = CMS2
hh hours
mm minutes
Default setting: The periodic test report is sent 24 hours after the last
reported event.
7.7 Disabling CMS communication
If you need to disable all CMS reports temporarily, you can do this,
while retaining your settings:
0 0 p 0 all reports to CMS p disabled
0 0 p 1 all reports to CMS p enabled
Default setting: all CMS reports disabled.
7.8 CMS 2 as a back up for CMS1
CMS 2 can serve as an optional back-up for CMS if data transfer to
CMS1 fails. When the first event is transferred to the backup
monitoring station (CMS2) an event “tel. line #1 communication fault“
will be reported.
080 CMS1 and CMS2 are two independent stations
081 CMS 2 works as a back up for CMS 1.
When 081 is selected, CMS 2’s settings are used only in the case of
CMS 1 transfer failure.
Default setting: two independent CMSs.
7.9 Storing the event “data to CMS sent” into the event memory
By this sequence it is possible to disable recording of the event that
indicates that data to a CMS has been sent to the list of event in the
control panel.
Programming sequences:
090 The CMS data transfer event is not recorded
091 The CMS data transfer event is recorded
Default setting: The CMS data transfer event is recorded
8 The modem function
The GSM communicator can also be used as an external modem for
accessing the Internet (GPRS format). It is necessary to have GPRS
activated in the SIM card and to have a connection cable connected to the
COM port of the PC. Support for MS Windows operating systems can be
found on the enclosed CD. The modem can only be used when all CMS
reports, SMSs and system calls have been executed.
When the modem is used:
It is possible to use the attached telephone, the internet connection will
be temporally suspended
Received SMSs are stored and they will be processed after modem
disconnection
The modem will be disconnected if an alarm or an arming event occurs
9 Additional information
9.1 Priorities for event reporting:
If the dialer is activated to send an event report it will:
send information to CMS1 (trying primary and back up
numbers twice) if programmed
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron JA-60GSM bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron JA-60GSM in de taal/talen: Engels als bijlage per email.

De handleiding is 0,19 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Jablotron JA-60GSM

Jablotron JA-60GSM Gebruiksaanwijzing - English - 6 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info