554884
4
Verklein
Vergroot
Pagina terug
1/11
Pagina verder
JA-60GSM dialer module 4 / 11 MFJ51215
3.3 Telephone number table
4 Customization of SMSs and audible reports
The default text and audible reports sent can be modified.
The dialer can report all possible events of the alarm system by SMS
(see table 4.1.1).
It is possible to set which events will be reported to which telephone
number.
There are factory default SMS texts available for all possible events and
for all possible event sources. All these texts can be edited.
It is possible to set which events should activate audible warnings.
The communicator can report all possible events by dialing programmed
numbers and playing an audible warning - if the call is answered
It is possible to change SMS command texts, which are used for remote
control of the system.
First enter the programming mode if you are going to use the following
programming sequences:
4.1 Events to be reported by SMS
Table 4.1.1 shows the complete list of all possible events in the alarm
system together with each corresponding index number. It also shows
which events are assigned to which telephone numbers to be reported
by SMS. You can make your own setting by using:
81 uu t y
where
uu is the event index from 01 to 31 (see table 4.1.1)
t is a telephone number memory location from 1 to 8
y 0 = reporting disabled, 1 = reporting enabled
Note: SMS reports consist of 4 text parts (installation name, event
name, event source name and time) – all of these texts can be edited
and customized, see section 4.2 for details. In a single SMS there can
be up to 160 characters using ASCI format, or 65 characters using
UNICODE format. Exceeding these limits will result in split messages.
The event “Internal communication failure” is generated if any of the
wireless detectors are lost under RF supervision.
The event “External communication failure” is generated if there is a
GSM signal outage longer than 15 minutes. The release of this event
is possible when GSM signal monitoring is set to ON.
Example: if you enter 810381 and a Fire alarm is triggered (event
index 03) by detector number 1, the following message will be sent to
the 8
th
telephone number: “Alarm system reports: Fire alarm Wireless
detector #1 Time: 16.04. 11:16”
4.1.1 Table – SMS report assignments to telephone numbers
Telephone numbers Event index
uu
Event
1 2 3 4 5 6 7 8
01 Intruder alarm instant zone x x x x x x
02 Intruder alarm delayed zone x x x x x x
03 Fire alarm x x x x x x
04 Panic alarm x x x x x x
05 Wrong access code alarm x x x x x x
06 Alarm after power on x x x x x x
07 Tamper alarm x x x x x x
08 Tamper OK
09 Alarm end
10 Alarm canceled by a user x x x x x x
11 Arming
x x
12 Disarming
x x
13 Partial arming (Home) x x
14 No code arming x x
15 External communication failure x x x x x x x
16 External communication recovery
17 Failure x x x x x x x
18 Failure recovery
19 AC failure longer than 30 minutes x x x x x x x
20 AC failure
21 AC recovery
22 Battery failure x x x x x x x
23 Battery recovery
24 Enter programming mode
25 Exit programming mode
26 Remote access
27 Remote access end
28 RF jamming
29 Internal communication failure x x x x x x x
30 Internal communication recovery x x x x x x x
31 Periodic test
The x marks in the table show which events are assigned to which telephone numbers for SMS reporting. If you modify these, we recommend you to
mark your settings in the table.
Memory
Entry
sequence
Reporting mode for the two corresponding phone numbers: Notes
1 71 ______ F0
2 72 ______ F0
- ALARM SMS if there is any type of alarm in the system (intruder, fire, tamper, panic).
- Technical SMS about events in the system.
3 73 ______ F0
4 74 ______ F0
- ALARM SMS if there is any type of alarm
- ALARM CALL notifies the called person (if you answer such a call, you will hear an
audible warning).
- Technical SMS about events in the system.
5 75 ______ F0
6 76 ______ F0
- ALARM, ARMING & DISARMING SMS.
- ALARM CALL notifies the called person (if you answer such a call, you will hear an
audible warning).
- Technical SMS about events in the system.
7 77 ______ F0
8 78 ______ F0
- ALARM CALL notifies the called person (if you answer such a call, you will hear an
audible warning). This setting is suitable for notifying landline numbers. -
Technical SMS about events in the system. This position is reserved only for the
service/installer organization.
Only numbers, which can accept
SMS, should be entered for the SMS
reports (mobile phones, provider’s
call centers etc.)
Audible warnings can be sent both to
mobiles and to landlines too
The communicator can report all
possible events from the alarm
system, not only the events listed in
the table above. See section 4 for
details.
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron JA-60GSM bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron JA-60GSM in de taal/talen: Engels als bijlage per email.

De handleiding is 0,19 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Jablotron JA-60GSM

Jablotron JA-60GSM Gebruiksaanwijzing - English - 6 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info