555042
3
Verklein
Vergroot
Pagina terug
1/5
Pagina verder
GSM pager CA-1802 „Athos“ 3/5 MHF57402
1.1 Configuration table - be careful to put spaces between words in SMSes (e.g. MASTER RESET 3).
SIM entry* SMS instruction Text Description
RESET EN 3
(After which, the
entry is erased
from the SIM)
MASTER RESET EN 3 Mode setting. RESET 3 = GSM pager for cars with an installed car alarm. Performing the RESET
instruction is indicated by 4 beeps. Consequently, all settings, enrolled remote controllers and wireless
detectors will be erased.
Not applicable MASTER UC uuuu
User code setting – the code allows you to operate the GSM pager remotely via SMS from
unauthorized phones. uuuu is a new user code, 4 to 8 letters (A–Z & 0–9, case insensitive). Factory
default user code is USER
Not applicable MASTER MC xxxx Master code setting –xxxx is a new master code (A–Z & 0–9, case insensitive). The code allows you
to change the maintenance settings for the GSM pager. Factory default master code is MASTER
TEL1 xx...x MASTER TEL1 xx...x
TEL2 xx...x MASTER TEL2 xx...x
TEL3 xx...x MASTER TEL3 xx...x
TEL4 xx...x MASTER TEL4 xx...x
Setting of phone numbers to report alarms to (these phones will also be authorized to control the
alarm via SMS without a user password)
E.g.: MASTER TEL2 +420602123456 will enter the phone number into memory TEL2
MASTER TEL3 0 will erase the memory TEL3.
DIAL1 xx...x
MASTER DIAL1 xx...x
DIAL2 xx...x
MASTER DIAL2 xx...x
DIALA xx...x
MASTER DIALA xx...x
DIALB xx...x
MASTER DIALB xx...x
Setting the phone numbers to dial using Hands free.
E.g.: MASTER DIAL2 +420602123456 will assign the number to the
button of the remote
controller. MASTER DIAL2 0 will erase the number assigned to the
button.
Not applicable MASTER LEARN RC Enrollment of RC-8x controllers - up to 4 controllers can be enrolled, turn the ignition key on before
sending the instruction. To enroll controllers, press and hold buttons
and together for 3
seconds. After you have enrolled all remote controls, turn the ignition key off. By enrolling the first
controller all other controllers previously enrolled will be erased. All the desired controllers should be enrolled in
a single enrollment session.
DIP abcdefghij MASTER DIP
abcdefghij
DIP parameter entry – see the DIP table
SET abcdefghij MASTER SET
abcdefghij
SET parameter entry – see the SET table
TELU xx...x MASTER TELU xx...x SIM card validity maintenance call setting (for pre-paid cards) 1x month the xx..x number is called,
call duration 10 s to maintain the validity of SIM cards requiring this.
Not applicable MASTER TXT 01,text
Modifying SMS messages and instructions (see chapter 9.1). The maximum length of a single text
is 30 characters. Information texts (with indices starting at 27) can be modified using the user code
USER (optional). To change instruction texts (indexed by 01 to 26) the MASTER installation code is
always necessary.
*It is not possible to modify access codes or SMS texts, or to enroll controllers or detectors by storing numbers in the SIM card phone directory
Always use CAPITAL letters when writing into the SIM card!!!
6. DIP parameters
Parameters A to J correspond to DIP switches. Setting is performed by
the SMS command: MASTER DIP ABCDEFGHIJ
Description
DIP
0 1
A Not applicable for this mode (a “0” can be entered).
B Silent alarm
Audible alarm
C
SMS alarm report only
SMS alarm report and siren sound
phone call
D SMS remote control not
confirmed by SMS reply
SMS remote control instructions
confirmed by SMS reply
E Not applicable for this mode (a “0” can be entered).
F Not applicable for this mode (a “0” can be entered).
G
User can not change SMS
Texts
User can change SMS texts by TXT
Sequence
H Not applicable for this mode (a “0” can be entered).
I Enter 2 for the immobilization by an SMS. No other option is
available for a GSM pager.
J
Self-location disabled
The car’s location will be sent by
SMS after an IMO instruction has
been performed.
Factory default setting is DIP 1111000000 (bold letters in the text).
7. SET parameters
Parameters A to J correspond to SET switches. Setting is performed by
the SMS command: MASTER SET ABCDEFGHIJ
Description
SET
0 1
A Not applicable for this mode (a “0” can be entered).
B Not applicable for this mode (a “0” can be entered).
C Not applicable for this mode (a “0” can be entered).
D
Instant activation input:
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
E INP1 logic:
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
F Not applicable for this mode (a “0” can be entered).
G Not applicable for this mode (a “0” can be entered).
H Not applicable for this mode (a “0” can be entered).
I
Do not turn off the GSM
module automatically.
Turn the GSM module off after
30 minutes of inactivity.
J 0 = AUX output is a bus for communication with CR-11A modules
1 = AUX output provides power for external sensors
Factory default setting is DIP 1001111101 (bold letters in the text).
If you want to change only particular DIP or SET parameters, enter x for the others.
8. SMS control from an authorized phone
Text SMS Description
IMO
STOP (immobilize) the vehicle (after turning ignition key off)
UNIMO
Unblock (mobilize) the vehicle
STATUS
Reply with status information, e.g. GSM pager reports:
Time: 27.01.04 13:04, Status: Armed, Unblocked, Ignition
of“.
HELP
The car alarm will reply with a brief list of SMS instructions.
UC xxxx
To change the user code. xxxx is the new user code, 4 to 8
characters (A –Z & 0 – 9). Factory default user code is
USER
CREDIT
parameter
To obtain the balance of a prepaid SIM card if used. See
12.3 for details
AUX
parameter
To operate CR-11A output relays as well as the appliances
or circuits that are connected to these relays (see par. 13)
HF abcdef
Hands-free set adjustment:
a – enable calls (0= disabled, 1=enabled)
b – auto answer incoming calls (0= disabled, 1=enabled)
c – microphone sensitivity 0 to 9, (5)
d – speaker volume 0 to 9, (5)
e - ringing tone volume 0=mute to 9= max., (5)
f – ringing sound 0 to 9, (1)
SIREN
To activate the siren for 30 seconds
The instruction must contain spaces (e.g. HF 105551).
If an SMS instruction is sent from an unauthorized phone, it is
necessary to put a user code before the instruction (default is USER).
Again, a space is necessary. Example: USER IMO
SMS instructions are not case-sensitive. Only basic ASCII can be used
in the SMS instruction texts.
If the SMS text contains the % sign, then the following text will be
ignored. Characters %% in the message stop processing the
following text. Using these characters is suitable when sending an
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron CA-1802 - Athos GSM RESET 3 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron CA-1802 - Athos GSM RESET 3 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,23 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Jablotron CA-1802 - Athos GSM RESET 3

Jablotron CA-1802 - Athos GSM RESET 3 Gebruiksaanwijzing - English - 16 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info