11.0 - SYSTEM PROGRAMMING
The t
E
able below applies to the system programmed in “standard configuration”.
very time you enter the programming procedure, the alarm resets to the default settings.
FUNCTION STATUS LED FLASHES
Disabled
Enabled
Disabled
Disabled
Disabled
Enabled
Disabled
-----
Exclusion of arming/disarming optic signalling
Exclusion of arming/disarming acoustic signalling
System passive arming
Arming of self-powered coded siren
Doors input - positive
Optical pulse signalling
Negative output during alarm cycle
For Gemini only, turn ignition key
PAGE 12 - INSTALLER MANUAL INSTALLER MANUAL - PAGE 13
11.7 -
).
NEGATIVE OUTPUT SELECTION (DURING ALARM) FOR HORNS OR ADDITIONAL
SIREN
Once activated, this function can activate the output for the siren (continuous tone) or for the horn
(intermittent tone
If the function is disabled, under normal operating conditions, the blue wire carries a negative signal;
during an alarm cycle, there is a lack of negative.
12.0 - SYSTEM PROGRAMMING EXAMPLE
.
Here below is an example that illustrates the various steps to follow to modify the programmable
functions.
As mentioned before, every key rotation disables a function, while the electronic key enables it.
When ignition is turned On or Off or the electronic key is touched to its receptacle, a high or low pitched
signal sounds and the LED flashes according to table in chapter 11.0
In both cases, system moves on to the next function.
signals
Repeat steps above to enable or disable other functions.
When the last function is programmed (either with the electronic key or the ignition key), in
addition to the confirmation tone, the system gives two low-pitched and one high-pitched acoustic
and the turn indicators flash twice.
These last two signals indicate the end of the programming procedure.
With alarm system disarmed, turn ignition key “ON” and touch electronic key to
its receptacle.
ON
Two acoustic signals (a high and a low-pitched sound) and two flashes of the turn indicators
indicate that the system is in the programming procedure.
OFF-ON
Boop
Beep
Turn ignition “OFF” and then back “ON” to
disable the function.
A low-pitched acoustic signal confirms the
operation.
The LED flashes according to selected function
(from 1 to 8).
OR
Touch electronic key once to its receptacle to
activate the function.
A high-pitched acoustic signal confirms the
operation.
The LED flashes according to function the
selected function (from 1 to 8).
When the optical pulse signaling feature is activated, the blinkers will ONLY emit optical
signals during an alarm cycle.
The system BLUE wire MUST be connected to the Hazard push-button.
In this case, do not connect the ORANGE wires (see chapter 7.3)
!
Alack of power during electrical system maintenance, will not affect the programming.
The procedure must be carried out entirely because key rotation disables the selected function and
moves to the next one until the programming procedure is completed.
Programmable functions are briefly described below and the next paragraph illustrates the
programming instructions.
This function activates optic signals during system arming (1) and disarming (2).
11.1 - OPTICAL SIGNALS
If the vehicle already has optical locking/unlocking signals, the turn indicators alarm
flashes should be deactivated.
11.2 - ACOUSTIC SIGNALS
11.3 - PASSIVE ARMING
11.4 - ENABL
11.5 - DOOR SWITCH POLARITY SELECTION
11.6 - OPTICAL PULSE SIGNAL/SELF-POWERED SIREN
This function activates acoustic signals during system arming (1) and disarming (2).
.
(art. 7725).
This function modifies the alarm input signal (positive or negative) according to the signal generated
This function activates the optical
.
This function arms the system 60” after ignition is switched off and the last door is opened and closed.
If a door is opened during this lapse of time, the procedure is interrupted and it is resumed when the
door is closed
by the doors switch.
signals according to the connection made; only for vehicles where
hook-up is to the “emergency” push-button wire (Hazard push-button)
ING OF SIREN (7725) OUTPUT
This function enables the relative output (20-way connector, position 13, PINK wire) to activate the
self-powered coded siren
!
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gemini 933 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gemini 933 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,6 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Gemini 933

Gemini 933 Gebruiksaanwijzing - Deutsch - 9 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info