624852
9
Verklein
Vergroot
Pagina terug
1/15
Pagina verder
E-64
Auto Save Values
Auto save values are one type of data stored in the memory of your watch.
Auto Save Values
High Altitude (
MAX
)
Low Altitude (
MIN
)
Total Ascent (
ASC
)
Total Descent (
DSC
)
These values are checked and updated automatically by the watch as altitude auto measurements are
taken.
Auto save is performed only while the watch is in the Altimeter Mode.
Cumulative ascent and cumulative descent values are updated whenever there is a difference of at
least ±15 meters (±49 feet) from one reading to the next.
Auto save values also include the date and time each value was recorded.
How High and Low Altitude Values are Updated
With each auto save reading, the watch compares the current reading against the
MAX
(high altitude) and
MIN
(low altitude) values. It will replace the
MAX
value if the current reading is at least 15 meters (±49
feet) greater than
MAX
, or the
MIN
value if the current reading is at least 15 meters (±49 feet) less than
MIN
.
E-65
How Cumulative Ascent and Cumulative Descent Values Are Updated
Session start point
20 m
0 m
120 m
320 m
620 m
Session end point
The total ascent and total descent values produced by an Altimeter Mode reading operation session
during the example climb illustrated above are calculated as follows.
Total Ascent:
q
(300 m) +
e
(620 m) = 920 m
Total Descent:
w
(320 m) +
r
(500 m) = 820 m
E-66
Entering the Altimeter Mode starts a new altitude auto reading session, but it does not reset the current
ASC
and
DSC
values or change them in any way. This means that the starting
ASC
and
DSC
values
for a new Altimeter Mode auto reading session are the values that currently are in memory. Each time
you complete an altitude auto reading session by exiting the Altimeter Mode, the total ascent value of
the current session (920 meters in the above example) is added to the session’s starting
ASC
value.
Also, the total descent value of the current auto reading session (–820 meters in the above example) is
added to the session’s starting
DSC
value.
Note
The high altitude, low altitude, total ascent, and total descent values are retained in memory when you
exit the Altimeter Mode. To clear values, perform the procedure under “To delete a specifi c record”
(page E-86).
E-67
How does the altimeter work?
Generally, air pressure decreases as altitude increases. This watch bases its altitude reading on
International Standard Atmosphere (ISA) values stipulated by the International Civil Aviation Organization
(ICAO). These values defi ne relationships between altitude and air pressure.
Note that the following conditions will prevent you from obtaining accurate readings:
When air pressure changes because of changes in the weather
Extreme temperature changes
When the watch itself is subjected to strong impact
There are two standard methods of expressing altitude: absolute altitude, which expresses an absolute
height above sea level, and relative altitude, which expresses the difference between the altitudes of two
different places. This watch expresses altitudes as relative altitude.
Height of building 130 m
(relative altitude)
Rooftop at an altitude of
230 m above sea level
(absolute altitude)
Sea Level
Regular calibration of the watch in accordance with values provided by local altitude (elevation) indications
is recommended before taking readings in order to maximize reading accuracy (page E-56).
E-68
Altimeter Precautions
This watch estimates altitude based on air pressure. This means that altitude readings for the same
location may vary if air pressure changes.
Do not use this watch for altitude reading or perform button operations while sky diving, hang gliding,
or paragliding, while riding a gyrocopter, glider, or any other aircraft, or while engaging in any other
activity where there is the chance of sudden altitude changes.
Do not use this watch for measuring altitude in applications that demand professional or industrial level
precision.
Remember that the air inside of a commercial aircraft is pressurized. Because of this, the readings
produced by this watch will not match the altitude readings announced or indicated by the fl ight crew.
E-69
Precautions Concerning Simultaneous Altitude and Temperature Readings
For the more accurate altitude readings, leaving the watch on your wrist is recommended in order to
maintain the watch at a constant temperature.
When taking temperature readings, keep the watch at as stable a temperature as possible. Changes in
temperature can affect temperature readings. See product specifi cations (page E-111) for sensor
accuracy information.
E-70
Taking Barometric Pressure Readings
This watch uses a pressure sensor to measure air pressure (barometric pressure).
To take barometric pressure readings
Use
B
to select the Barometer Mode (BARO), as shown on page
E-30.
BARO
will appear on the display, indicating that barometric pressure
reading is in progress. The results will appear on the display after
about one second.
After a barometric pressure reading operation is started, the watch will
take readings every fi ve seconds for the fi rst three minutes, and then
every two minutes after that.
To restart a reading operation from the beginning, press
A
.
The watch will return to the Timekeeping Mode automatically if you do
not perform any operation for about one hour after entering the
Barometer Mode.
Note
When you press
B
above, the second hand may indicate seconds (of
the current time) or the barometric pressure differential (page E-73).
The initial second hand function will be the same as what was selected
the last time you took a barometric pressure reading. To toggle
between the two second hand functions (indicating seconds or
indicating the barometric pressure differential) press
D
.
Barometric
pressure graph
Barometric
pressure
Barometric
pressure graph
Barometric
pressure
E-71
Barometric Pressure
Barometric pressure is displayed in units of 1 hPa (or 0.05 inHg).
The displayed barometric pressure value changes to
- - -
if a measured
barometric pressure falls outside the range of 260 hPa to 1,100 hPa (7.65
inHg to 32.45 inHg). The barometric pressure value will reappear as
soon as the measured barometric pressure is within the allowable range.
Display Units
You can select either hectopascals (hPa) or inchesHg (inHg) as the
display unit for the measured barometric pressure. See “To specify
altitude, barometric pressure, and temperature units” (page E-52).
Barometric Pressure Graph
Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
This watch takes barometric pressure reading automatically every two
hours. Readings are used to produce barometric pressure graph and
barometric pressure differential pointer readings.
Barometric pressure
change indicator
Barometric pressure
Barometric pressure
change indicator
Barometric pressure
Barometric pressure graphBarometric pressure graph
Operation Guide 5365
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Casio 5365 - PRW-6000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Casio 5365 - PRW-6000 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,97 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Casio 5365 - PRW-6000

Casio 5365 - PRW-6000 Gebruiksaanwijzing - Deutsch - 15 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info