AIR CONDITIONER FUNCTIONS
The air conditioner has three functions: cool, dry, and fan ventilation.
Introduction
Make sure the water container (D) is properly installed. Otherwise the appliance will not operate.
Plug the appliance only to a grounded AC socket connected to a protection circuit.
Do not connect the appliance to a multiple socket outlet which is also being used for other electrical appliances.
Insert the plug into a power source and Press the ON/OFF (8) button on the control panel for the appliance to start operating.
Cooling operation
Press the MODE button (10) several times until the “COOL” indicator light comes on: cooling operation (10c).
Press the “TEMP SETTING” buttons (7) and (9) to select the desired room temperature. The temperature can be set within a range of
17°C-30°C/62°F-88°F.
Press the “FAN SPEED” button (11) to select the fan speed: low (11a), med (11b) or high (11c).
NOTE: In order to improve the cooling efciency follow the instructions below:
1. Draw the curtains if the room is directly exposed to the sun.
2. Do not place the air conditioner near other heat sources.
Dehumidifying operation
Press the MODE button (10) several times until the “DRY” indicator light comes on: dehumidifying operation (10b).
During the dehumidifying mode the fan speed and the temperature cannot be adjusted. The fan motor operates at high speed.
Keep windows and doors closed for best dehumidifying effect.
Do not put the duct to the window.
CAUTION: If the compressor cycle is interrupted during the cooling or dehumidifying mode (appliance unplugged, power failure)
and reinstated immediately thereafter, a compressor protection circuit is automatically self-affected. The compressor cannot oper-
ate during a compressor protection condition. It may take about 3 minutes before the protection circuit deactivates (this is a normal
situation).
Ventilation
Press the MODE button (10) several times until the “FAN” indicator light comes on: ventilation (10a).
Press the “FAN SPEED” button (11) to select the fan speed: low (11a), med (11b) or high (11c).
The temperature cannot be adjusted.
Do not put the duct to the window.
AUTOMATIC SWITCH ON / SWITCH OFF
Timer operation (setting the on timer)
Press the TIMER ON (4) button when the appliance is plugged in to a power source.
Press and hold or keep pressing the TIMER ON (4) button to set the time after which the appliance will automatically switch on. The time
is programmed as: 0,5 - 1,0 - 1,5 - 2,0 - 2,5 - 3,0 - 3,5 - 4,0 - 4,5 - 5,0 - 5,5 - 6,0 - 6,5 - 7,0 - 7,5 - 8,0 - 8,5 - 9,0 - 9,5 - 10 - 11 -12 - 13 - 14
- 15 - 16 - 17 - 18 - 19 - 20 - 21 - 22 - 23 - 24 - 0,0 hours
The starting time is adjustable from 0,0 – 24.
Timer operation (setting the off timer)
Press the TIMER OFF (4) button when the appliance is operating.
Press and hold or keep pressing the TIMER OFF (5) button to set the time after which the appliance will automatically switch off. The
time is programmed as: 0,5 - 1,0 - 1,5 - 2,0 - 2,5 - 3,0 - 3,5 - 4,0 - 4,5 - 5,0 - 5,5 - 6,0 - 6,5 - 7,0 - 7,5 - 8,0 - 8,5 - 9,0 - 9,5 - 10 - 11 12 - 13
- 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - 22 - 23 - 24 - 0,0 hours
The switching off time is adjustable from 0,0 – 24.
WATER DRAINAGE METHODS
There are two possible methods of water drainage available for this appliance – water container drainage or continuous drainage.
Water container drainage
A) During cooling mode
When the water level inside the water container (D) reaches a predetermined level, the appliance will switch off automatically. The motor
fan will continue to operate.
Carefully remove the water container (D) and dispose of the water. Replace the water container back to its original position.
B) During the dehumidifying mode
Water will accumulate in the water container (D). When the water container is full, the Water Full indicator (3) will illuminate and the dehu-
midication process will automatically stop. However, the fan motor will continue to operate (this is a normal situation). Carefully remove
the water container and dispose of the water. Replace the water container back to its original position. The dehumidication process will
automatically resume. It may take 3–5 minutes for the compressor to restart. This is a normal situation.
Continuous drainage
The continuous drainage option can be selected during the cooling and dehumidifying mode. Remove the water container (D).
Inside, beside the water container you will nd a section of the hose that is plugged at the end. Release the band and remove the plug
form the end of the hose.
Replace the water container (D) back to its original position and route the hose through the hole on the bottom of the water container.
Place the other end of the hose directly over the drain area.
CAUTION: Make sure the drain hose routed through the water container does not interfere with the correct positioning of the water
container. Otherwise the fail-safe switch mechanism will be activated, not allowing the appliance to operate.
53

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Zelmer 23Z010 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Zelmer 23Z010 in de taal/talen: Engels, Pools als bijlage per email.

De handleiding is 1,74 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info