668531
5
Verklein
Vergroot
Pagina terug
1/18
Pagina verder
USER GUIDE
GB
RF basic thermostat WFHTRF 010 (20433)
TECHNICAL CHARACTERISTICS
MODES DESCRIPTION
- Radio frequency RF thermostat (433.92 Mhz) specially designed for
water floor heating. (Personal code on each product)
- Equipped with a LCD display to select comfort (
), Off or night
reduction (
) mode.
- Setting and room temperature displayed.
- To be used only with ours receivers.
PPL IMP 1014A
Measured temperature
precision
0.1°C (or 0.2°F)
Operating temperature 0°C - 50°C (or 32°F – 122°F)
Setting temperature range
5°C - 37°C by 0.5°C step
(or 41°F - 99°F by 0.5°F step)
Regulation characteristics
Proportional Integral regulation (adjustable see installation
menu) Cycle: 15 minutes or
Static differential 0.3°K
Anti-short cycle: 3min in OFF, 2min in ON.
Electrical Protection Class II - IP30
Power Supply
Battery operated life
2 x 3V (CR2430)
~ 2 years
Radio frequency 433.92 MHz, <10mW.
certifications
CE. EN 300220-1, EN 301489-1
(Radio frequency certifications)
Soft version Displayed when the thermostat is turn Off
RADIO CONFIGURATION MODE
- To assign (*) the RF thermostat with the receiver you must put the
receiver in “RF init” mode (please refer to the receiver leaflet).
- After you have just Press “Ok” key during 5 sec, when the display( rF “”)
The thermostat sends its configuration address by radio signal.
- When the receiver is configured, Press “Ok” key to return to user menu.
* (In this mode the thermostat should be near the receiver)
COMFORT operating mode:
Force comfort temperature operation
indefinitely.
By pressing +/- keys the comfort
temperature starts to blink and can be
adjusted.
The measured temperature
reappears after a few seconds.
OFF mode:
Use this mode if your Heating
installation needs to be turned OFF.
The display is blank.
(Careful in this mode your installation
can freeze)
Parameters are saved.
REDUCED operating mode:
Force reduced temperature operation
indefinitely.
By pressing +/- keys the comfort
temperature starts to blink and can be
adjusted.
The measured temperature
reappears after a few seconds.
1: Operating mode menu
2: Heater indication
3: Cooler indication
4: Batteries weak
5: If lit-up 6 displays the measured temperature
6: Measured temperature or set temperature
7: Moving bars when transmitting a radio signal
Or Title for installation Parameters (rF, J0,CLr…)
DISPLA
Y
Press the OK key during 5 seconds, Then use + or - keys to select the installation parameter to be adjusted.
Press OK to toggle the parameter setting or edit the value. If the value starts to blink you can use + / - keys to adjust this
value. Press + & - keys at the same time to reset this value to the factory default value. Once you have adjusted the
value press OK to validate this parameter value.
When you have finished, use + / - keys to go to ‘rF’ display and then press OK key to exit installation parameter menu.
rF : Radio configuration mode (see section). Press OK to return to normal operation modes.
J0 : °C
/ °F temperature display selection
J1 : “Hot”
/ “Cold” regulation mode. Select Hot for a Heater system, select Cold for a Cooling system
Cy : Proportional Integral regulation time cycle value in minutes (default: 15 minutes cycle)
bp : Proportional Integral regulation band amplitude value in degrees °C/°F (default: 2.0°C
/3.6°F)
J5 : Select “PMP” to perform an 1 minute exercise everyday (if installation inactive during a day)
J6 : Air or Floor temperature regulation selection. (if no Floor sensor, regulation will use Air sensor)
J7 : “rEG” (Proportional Integral) or “HYs” (0.3°K Hysteresis) regulation type selection
Cp : compensation value in °C/°F (default: 2.0°C
/3.6°F) this parameter must be adjusted by a professional.
Ao : Air sensor offset adjustment (default: no offset). Display measured Air sensor value
Fo : Floor sensor offset adjustment (default: no offset). Display measured Floor sensor value
FL : Floor temperature LOW limitation (default: 5°C
/41°F), effective only if floor sensor present
FH : Floor temperature HIGH limitation (default: 28°C/82°F) , effective only if floor sensor present
CLr : Press OK key during 5s to reset all the WFHT LCD parameters to factory defaults
* (Default parameters are underlined.)
INSTALLATION PARAMETERS MENUS
Optional external sensor 10K
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Watts WFHTRF 010 -20433 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Watts WFHTRF 010 -20433 in de taal/talen: Engels, Spaans als bijlage per email.

De handleiding is 4,06 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Watts WFHTRF 010 -20433

Watts WFHTRF 010 -20433 Gebruiksaanwijzing - Nederlands - 2 pagina's

Watts WFHTRF 010 -20433 Gebruiksaanwijzing - Deutsch - 4 pagina's

Watts WFHTRF 010 -20433 Gebruiksaanwijzing - English - 4 pagina's

Watts WFHTRF 010 -20433 Gebruiksaanwijzing - English - 4 pagina's

Watts WFHTRF 010 -20433 Gebruiksaanwijzing - English - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info