598220
439
Verklein
Vergroot
Pagina terug
1/476
Pagina verder
IEEE-488 Bus Overview
2001-900-01 Rev. K / August 2010 G-5
Addressed multiline commands
Addressed commands are multiline commands that must be
preceded by the device listen address before that instrument
will respond to the command in question. Note that only the
addressed device will respond to these commands. Both the
commands and the address preceding it are sent with ATN
true.
SDC (Selective Device Clear) — The SDC command per-
forms essentially the same function as the DCL command
except that only the addressed device responds. Generally,
instruments return to their power-up default conditions when
responding to the SDC command.
GTL (Go To Local) — The GTL command is used to re-
move instruments from the remote mode. With some instru-
ments, GTL also unlocks front panel controls if they were
previously locked out with the LLO command.
GET (Group Execute Trigger) — The GET command is
used to trigger devices to perform a specific action that de-
pends on device configuration (for example, take a reading).
Although GET is an addressed command, many devices re-
spond to GET without addressing.
Address commands
Addressed commands include two primary command groups
and a secondary address group. ATN is true when these com-
mands are asserted. The commands include:
LAG (Listen Address Group) — These listen commands
are derived from an instrument’s primary address and are
used to address devices to listen. The actual command byte
is obtained by ORing the primary address with $20.
TAG (Talk Address Group) — The talk commands are de-
rived from the primary address by ORing the address with
$40. Talk commands are used to address devices to talk.
SCG (Secondary Command Group) — Commands in this
group provide additional addressing capabilities. Many de-
vices (including the Model 2001) do not use these com-
mands.
Unaddress commands
The two unaddress commands are used by the controller to
remove any talkers or listeners from the bus. ATN is true
when these commands are asserted.
UNL (Unlisten) — Listeners are placed in the listener idle
state by the UNL command.
UNT (Untalk) — Any previously commanded talkers will
be placed in the talker idle state by the UNT command.
Common commands
Common commands are commands that are common to all
devices on the bus. These commands are designated and de-
fined by the IEEE-488.2 standard.
Generally, these commands are sent as one or more ASCII
characters that tell the device to perform a common opera-
tion, such as reset. The IEEE-488 bus treats these commands
as data in that ATN is false when the commands are transmit-
ted.
SCPI commands
SCPI commands are commands that are particular to each
device on the bus. These commands are designated by the in-
strument manufacturer, and are based on the instrument
model defined by the Standard Commands for Programma-
ble Instruments (SCPI) Consortium’s SCPI standard.
Generally, these commands are sent as one or more ASCII
characters that tell the device to perform a particular opera-
tion, such as setting a range or closing a relay. The IEEE-488
bus treats these commands as data in that ATN is false when
the commands are transmitted.
Command codes
Command codes for the various commands that use the data
lines are summarized in Figure G-3. Hexadecimal and the
decimal values for the various commands are listed in Table
G-2.
439

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Keithley 2001 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Keithley 2001 in de taal/talen: Engels als bijlage per email.

De handleiding is 2,31 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info