JK-15 PROFI GSM KIT 2/4 MGK22902
4. Detectors and accessories installation
a) Install the JA-60N magnetic detector to a door (antenna
pointing up or down)
b) Install the JA-60P motion PIR detector
A
attach
C
open
B
click
rear tamper
lever
Don't over-tighten
this screw
2
2,5
1,5
1
0,5
1,6 3,7
12
range
[m]
height
[m]
120
ş
1
2
m
zone A
zone B
zone C
zone A
zone B
zone C
JA-60P coverage
Avoid locations facing windows or close to heaters
Select Instant or Delay reactions via the DIP switches inside
the detectors.
c) Connect the detector batteries (pull out the red tape to
activate the batteries)
d) Attach the keypad to the desired location
e) Plug the UC-260 wireless siren into a power socket.
5. Enrollment of additional accessories
If you install additional detectors (max. 32), you have to enroll
them. The system should be in the P mode (if not enter F0 6060):
a) Press 1 to enter the learning mode*
b) The next free detector position will be displayed on the
keypad.
c) Install batteries into all new detectors step by step to enroll
them (system will automatically offer the next free position)
d) To scroll through the sensor positions, press 1 (up) or 7
(down)
e) To enroll a second detector to an occupied position press 5
before you install the detector batteries
f) To exit the learning mode press the N key
The wireless keypad (JA-60F) enrolls after you install its battery
while in the learning mode.
The remote control (RC-4x) enrolls after you press and hold
both the
and buttons while in the learning mode.
The wireless outdoor siren (JA-60A) enrolls after it is powered
up while in the learning mode
To enroll the control panel to UC receivers enter 299 on the
keypad while in the P mode
Check the manuals of individual items for more details
*Learning mode will also be entered after shorting the Reset pins
in the control panel.
6. Detector and controller testing
a) The system should be in P mode (if not, enter F0 6060)
b) Trigger the detectors – their addresses (1=door and 2=PIR)
should be displayed (if the PIR detector does not react, re-
enter its test mode by opening and closing its cover)
c) Press button
on the RC-4x remote control c2 will be
indicated on the alarm display
7. Radio signal strength measurement
a) While in P mode, press 1 and then using 7 scroll to position 1
b) Press 8 to start measuring
c) Activate the door detector to view its signal strength
d) Using the 1 key, scroll to the next position (2=PIR) and
check its signal strength (if the PIR detector does not react,
re-enter its test mode by opening and closing its cover)
e) Repeat step d) to check all enrolled items. The wireless keypad
(c1) signal is indicated after you trigger its tamper. The remote
control (c2) is indicated after you press button
.
f) Change the location of an item if its signal is lower than 2
g) Return to P mode by pressing the N key
8. GSM communication testing
a) Call back the system number using your mobile. Let the SMS
phone ring until the system answers your call (you will hear a
beep). Then enter the installer remote access code 0000 on
your mobile.
b) Now the mobile should work as a system keypad. Press the
# key to exit P mode and re-enter it by keying 0 6060
c) End the phone call
d) From your mobile, send a command SMS with MO in it to the
system. You should then receive a status report reply
9. Programming the system
a) The system should be in P mode (if not enter F0 6060)
b) Using the following sequences you can program:
Function Sequence
Comments
Your installer code* 5 xxxx xxxx
6060 = factory default
xxxx = new code
Installer remote
access code*
94 xxxx F0
0000 = factory default
xxxx = customized code
User remote access
code*
94 xxxx F1
1111 = factory default
xxxx = new code
Exit delay
20x
3=30sec factory def.
Entrance delay
21x
3=30 sec factory def.
Alarm duration
22x
4=4min factory def.
Alarm SMS reporting
71 yyy..y F0
72 yyy..y F0
Alarm SMS + phone
call reporting
73 yyy..y F0
74 yyy..y F0
Alarm & arming SMS
reporting
75 yyy..y F0
76 yyy..y F0
Alarm phone call
only
77 yyy..y F0
Technical trouble
SMS reporting
78 yyy..y F0
yyy..y = phone number
7nF0 erases number n
User 1 to 4 arming
reporting to 75 & 76
80x
x=1 enabled
x=2 disabled
GSMLink
pre-registration
972 yyy..yF0
yyy..y = your mobile
number (international
format 00 country …)
Time & date entry
4 hh mm DD MM YY
See control panel installation manual for more details
* Must be changed
JK-15 PROFI GSM KIT 3/4 MGK22902
10. SMS text editing
Factory default SMS texts in the system can be modified easily by
Jablotron’s Comlink software.
yyyyTXTz,text,z,text,z,text.....
yyyy = installer remote access code (0000 = factory default)
= separator, space can also be used
z = text index, see the following table
text = new text (no commas or periods/full stops allowed)
z Factory default text z Factory default text
700 Alarm system reports: 415 Wireless detector #15
201 Controller #1 416 Wireless detector #16
202 Controller #2 501 User code #1
203 Controller #3 502 User code #2
204 Controller #4 503 User code #3
205 Controller #5 504 User code #4
206 Controller #6 505 User code #5
207 Controller #7 506 User code #6
208 Controller #8 507 User code #7
401 Wireless detector #1 508 User code #8
402 Wireless detector #2 509 User code #9
403 Wireless detector #3 510 User code #10
404 Wireless detector #4 511 User code #11
405 Wireless detector #5 512 User code #12
406 Wireless detector #6 513 User code #13
407 Wireless detector #7 514 User code #14
408 Wireless detector #8
z Factory default
commands
409 Wireless detector #9 703 AM
410 Wireless detector #10 704 DM
411 Wireless detector #11 705 MO
412 Wireless detector #12 706 ME
413 Wireless detector #13 710 PGON
414 Wireless detector #14 711 PGOFF
A complete list of all texts is in the control panel installation manual
11. Finishing the installation
a) Fill in the information on the sticker label and attach it inside
the keypad cover.
b) Switch the system to standby (by pressing the N key)
c) Instruct the user on how to operate the system
12. Keypad operation
13. Specifications
Power 230 VAC, max 0.1 A, supervised, class II
Backup battery 12 V, 2.26 Ah, normal life time 5 years
Backup power output 13VDC, the max. permanent current is 0.4
or 1A for max. 15 min (1 cycle per hour),
Self consumption of the control panel is 30 mA; JA-60E 25 mA
Hard-wired inputs 4 input zones, selectable triggering:
Wireless zones 16 zones (2 detectors can be enrolled to each
Wireless controllers max. 8 (JA-60F, RC-22, RC-44)
Access codes master code and 14 user codes.
Wired outputs Alarm relay dry contacts 1A/60V;
Programmable outputs PgX , PgY connect to the GND max. 0,1 A
Siren output 12 V, 0.7 A
Events memory 127 most recent events
Working frequency*433.92 MHz; digital hopping code; supervised communication
Comply with EN 50131-1, EN 50131-6
Security grade 2 (low to medium risk)
Environmental class II indoor – general (-10 to 40oC)
Safety EN 60950, class II
EMC ETS 300683
Radio characteristics ETSI EN 300220
Can be operated according to ERC REC 70-03
Jablotron Alarms a.s. hereby declares that the JA-63 Profi control
panel is in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC. The original of the
conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Dispose of batteries safely depending on the type of the
batteries and local regulation. Although this product does not contain
any harmful materials we suggest you to return the product to the
dealer or directly to the producer after usage.
Entry Function
user code
Arming / Disarming
F1 /
Arming without code
F2 /
Partial arming
F3 /
Door lock opening
F4
Memory reading
F5
New master code (example: F5 1234 2789
2789)
F6 User code setting (example: F6 1234 03 3344)
F7 /
Disarming under duress
F8
Appliance control (F81 = ON, F80 = OFF)
F0 M.code
User test mode (example F0 1234)
N
Escape & fault detail reading
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron JK-15 - Profi set bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron JK-15 - Profi set in de taal/talen: Engels als bijlage per email.

De handleiding is 0,33 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info