The JA-89P wireless motion detector 2/2 MKU51102
Internet: www.jablotron.com
Tel.: 483 559 911
fax: 483 559 993
Pod Skalkou 33
466 01 Jablonec nad Nisou
45
90
45
You can restrict the detection angle by adhesive masking strips supplied
with the package. This way you can eliminate problematic parts of the
detection area. The strips are to be stuck on the relevant lens segment from
the inner side.
The PIR detection sensitivity can be configured by a 3-pole switch located
under the upper sensor. The letters correspond to sensitivity levels as follows:
L low – applicable to bad conditions
M middle
H high
Other parameters can be configured using a DIP switch:
LED indicator OFF LED indicator ON
120 s 5 s battery saving timer
4x 2x pulse count
The LED indicator is to be used for PIR detector testing. For normal detector
operation the indicator should be turned off in order to save the battery.
The JA-89P is capable of automatically switching to battery-save mode.
Triggering a PIR sensor is signalled to the control panel after which the
detector switches to sleep mode for a configurable time. During this time the
detector ignores any further movement.
A filter for detector signalling can be established by setting a trigger counter.
Either 2 or 4 triggering events (which have to be detected by both PIR
sensors due to the AND logic) can be configured to cause signals to be sent
to the control panel.
Testing operation
Turn the LED indicator on, set the battery-save timer to 5 seconds and close
the detector. Every 5 seconds any movement in the detection area will be
indicated by the LED indicator and the alarm information will be sent to the
control panel. You should test both the sensitivity to movements in the
detection area as well as the detector’s insensitivity to any movement outside
the area of protection. Take into consideration that the detection range may
vary according to local conditions.
After finishing the test, it is recommended to turn off the LED indicator and
set the battery-save mode duration to 120s.
Operation
The detector uses radio signalling for all types of detected events:
movement detection, cover opening, tearing the detector off its position, and
communication checking. The communication checking is automatically
performed at 9 minute intervals for the system to test that all its devices are
present and ready for operation.
Battery replacement
The detector monitors its battery voltage and if too low, a report is sent to
the control panel to inform the installer or user. The detector continues to
function. Battery replacement should not be delayed by more than one week.
Before battery replacement, you need to ensure that the receiver (control
panel) is put into a state which permits opening the detector cover. Only use a
lithium battery of type AA 3.6 V. After closing the cover, the detector starts to
operate in its normal mode.
Note:
The detector’s LED flashes if you accidentally insert a low battery.
The detector will not work after an expired battery has been inserted.
Trouble-shooting
Problem Probable cause Remedy
Lower detection area is
unnecessarily long.
Set the detection area
properly.
The detector is exposed to
direct/reflected light (sun
light, car lights etc.).
Remove the reflector,
mask the area exposed to
the reflection of light or
change the detector
position.
The detector
makes false
intrusion
alarms.
There is a moving object in
the area (laundry on the
clothes-line, plants etc.)
Remove the moving object
or change the detector
position.
The detection area is too
close to the detector.
Set the detection area
properly.
Sensitivity is set to low (L). Change sensitivity to
medium (M) or high (H).
Occasionally
no
The detector is in battery-
save mode.
While testing operation,
set the battery-save timer
to 5 seconds.
Low battery. Replace the battery.
LED does not light. Turn the LED switch ON.
Detector
ignores any
movements.
LED indicator lights but
there is no reaction in the
control panel.
The control panel is out of
range, check the battery,
try to reposition detector or
control panel.
80
198
108
Dimensions
Technical specifications
Voltage: Lithium battery type LS(T)14500 (3,6V AA)
Typical battery lifetime approx. 3 years (120 sec sleep mode)
Communication band 868 MHz
Communication range approx. 300 m (open area)
Specification of the Optex VX 402R detector
Coverage 10 m / 90°; 14 segments
Installation height 0.8 – 1.2 m
Detected speeds 0.3 – 1.5 ms
-1
Battery saving timer either 5 or 120 seconds
LED indicator only in test mode
Operational environment class IV, according to EN 50131-1
Security grade 2, according to EN 50131-1
Operational temperature range -20°C to +50°C
Enclosure IP54
Maximum relative humidity 95%
Dimensions 198 x 80 x 108 mm
Can be operated according to ERC REC 70-03
Security grade 2, according to EN 50131-1, CLCITS 50131-2-2, EN 50131-5-3
Jablotron Ltd. hereby declares that the JA-89P is in compliance
with the essential requirements and other relevant provisions of
Directive 1999/5/ES. The original of the conformity assessment
can be found on the web site www.jablotron.com
, Technical
Support section.
Note: Dispose of batteries safely depending on battery type and
local regulations. Although this product does not contain any
harmful materials we suggest you return the product to the dealer
or directly to the manufacturer after use.
123
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron JA-89P bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron JA-89P in de taal/talen: Engels als bijlage per email.

De handleiding is 0,2 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info