GSM pager CA-1202 „Athos“ 2/4 MHF52705
Figure 1: installation of the GSM pager in Mode 3
6.1 Programming sequences
Enter the prescribed spaces in SMS texts as shown in the table below. MASTER is a factory default master code, which should be changed to your own
password. All SMS texts are case insensitive.
* See part 5 for details.
SIM entry* Text of SMS instruction Description
RESET EN 3 MASTER RESET EN 3 Mode setting. Factory default is 0 – no function (immobilization relay copies ignition). Note: By
performing the RESET EN x instruction, all settings, remote controllers and enrolled wireless detectors
will be erased! RESET is indicated by four siren chirps.
Not possible MASTER UC uuuu
User Code setting – the code (password) allows you to operate the alarm remotely via SMS from
unauthorized phones. uuuu is a new user code, up to 8 characters (A –Z & 0 – 9). Factory default
user code is USER
Not possible MASTER MC xxxx Master Code setting, xxxx is a new master code, up to 8 characters (A –Z & 0 – 9).
The code allows you to change settings of the GSM pager. Factory default master code is MASTER
TEL1 xx...x MASTER TEL1 xx...x
TEL2 xx...x MASTER TEL2 xx...x
TEL3 xx...x MASTER TEL3 xx...x
TEL4 xx...x MASTER TEL4 xx...x
Setting of phone numbers to report alarms (these phones will also be authorized to control the
GSM pager via SMS without a user password)
E.g.: MASTER TEL2 +420602123456 will enter the phone number into the TEL2 memory
MASTER TEL3 0 will erase the TEL3 memory.
DIAL1 xx...x MASTER DIAL1 xx...x
DIAL2 xx...x MASTER DIAL2 xx...x
DIALA xx...x MASTER DIALA xx...x
DIALB xx...x MASTER DIALB xx...x
Setting of phone numbers to dial using Hands free.
E.g.: MASTER DIAL2 +420602123456 will enter the number into the DIAL2 memory (which is dialed
after you press button 2 on the remote control)
MASTER DIAL2 0 will erase the memory DIAL2.
DIP abcdefghij MASTER DIP abcdefghij DIP parameter entry – see part 7
SET abcdefghi MASTER SET abcdefghi SET parameter entry – see part 8
Not possible MASTER LEARN RC Remote Control enrollment - up to 4 controllers can be enrolled, turn the ignition key on before
sending the instruction. To enroll a remote control press and hold buttons A and B together for 3
seconds. After you enroll all remote controls, turn the ignition key off.
Not possible MASTER TXT 01,text Editing of SMS texts (reports and instructions), see part 10
TELU xx...x MASTER TELU xx...x Sustain call setting (for pre-paid cards) 1 x a month the xx..x number is called, call duration 10 s.
GSM pager CA-1202 „Athos“ 3/4 MHF52705
7 DIP parameters
By SMS: MASTER DIP ABCDEFGHIJ you can change 10 features:
Description
DIP
0 1
A no function in Mode 3 (set to 0)
B Silent alarm
Audible alarm (30 sec.)
C
SMS alarm report only
SMS alarm report + siren sound
phone call
D SMS remote control not
confirmed by SMS reply
SMS remote control instructions
confirmed by SMS reply
E no function in Mode 3 (set to 0)
F no function in Mode 3 (set to 0)
G
User can not change SMS
texts
User can change SMS texts by TXT
sequence
H no function in Mode 3 (set to 0)
I
0 = Immobilization by arming and by SMS instruction
1 = Immobilization by arming and automatically 5 minutes after ignition is
turned off and also by SMS instruction
2 = Immobilization only by SMS instruction
J
Self-location disabled
The car´s location will be sent by
SMS to numbers TEL1 to TEL4 if
there is an alarm or if the car stops
after the immobilization SMS
instruction (See 13.6.)
Factory default setting is DIP 1111000000 (bold letters in the text). If you
want to change only particular parameters, enter x for the others (i.e.
MASTER DIP x0xxxxxxxx).
8 SET parameters
By SMS: MASTER SET ABCDEFGHI you can change 9 features:
Description
SET
0 1
A no function in Mode 3 (set to 0)
B no function in Mode 3 (set to 0)
C no function in Mode 3 (set to 0)
D
Instant activation input logic:
0 = automatic
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
E INP1 logic:
0 = automatic
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
F no function in Mode 3 (set to 0)
G no function in Mode 3 (set to 0)
H no function in Mode 3 (set to 0)
I
Do not switch off the GSM
module
Switch off the GSM module
after 30 minutes of idle
Factory default setting SET 100000010 (bold letters in the text).
If you want to change only particular parameters, enter x for the others
(i.e. MASTER SET xxx0xxxxx).
9 User instructions
9.1 Remote control by SMS instructions
SMS instructions sent from an authorized phone (TEL1 to TEL4) can operate
the GSM pager remotely. Factory default instruction texts are shown in the
following table. The instruction texts can be changed by SMS text editing,
see part 10.
If an SMS is sent from an unauthorized phone (other than TEL1 to TEL4), a
valid user code must be entered before the instruction (e.g. USER IMO).
SMS text Description
IMO
STOP (immobilize) the car (after turning the ignition key off)
UNIMO
Unblock (mobilize) the car
STATUS
The GSM pager will reply with status information, e.g. “car
reports: Time: 27.01.04 13:04, Status: Armed, Unblocked,
Ignition off“.
HELP
The GSM pager will reply with a brief list of SMS
instructions.
UC uuuu
To change the user code. uuuu is the new user code, up to
8 characters (A –Z & 0 – 9). Factory default user code is
USER
CREDIT
To obtain the balance of a prepaid SIM card if used. See
13.5 for details
HF abcdef
Hands-free set adjustment:
a – enable calls (0= disabled, 1=enabled)
b – auto answer incoming calls (0= disabled, 1=enabled)
c – microphone sensitivity 0 to 9, (5)
d – speaker volume 0 to 9, (5)
e - ringing tone volume 0=mute to 9=max., (5)
f – ringing sound 0 to 9, (5)
LOCATOR
To obtain the car location from the GSM provider. See 13.4
The parameters in bold are factory defaults.
The instruction must contain spaces as shown in the table
Only basic ASCII can be used in the SMS instruction texts
If the SMS text contains the % sign, then the following text will be ignored.
9.2 Phone calls by an installed hands free set
If the optional HF-03 hands free set is installed, it is possible to receive
and make phone calls via the GSM pager. When the ignition key is on,
the remote control (RC-40) allows you to operate the hands free set.
Incoming calls – to answer them, press any button on the RC-40 remote
control. By pressing any button again, the call will be terminated.
When armed, all incoming calls are automatically rejected. If the car is
blocked (by IMO instruction) all calls are automatically answered (it is possible
to listen and to speak to the car remotely). Automatic call answering while you
are driving can also be enabled by the HF instruction (see 9.1).
To make a call – you can call up to 4 preprogrammed numbers while you are
driving. By pressing button A, B, 1 or 2 on the remote control you will dial the
corresponding number (pre-programmed by DIALA to DIAL2, see 6.1)
9.3 Alarm
When an alarm is triggered, the siren will sound for 30 sec., warning SMS
messages will be sent to all phones (TEL1 to TEL4) and these phones will
also be called with the siren sound.
10 SMS text editing
The SMS texts (alarm information and instructions) are factory
preprogrammed. However, it is possible to change these texts by a
mobile phone or via internet access using www.GSMlink.cz
To change a text by mobile phone, send the SMS:
MASTER TXT zz,text,zz,text,…
where: zz is the text index (see the following table)
text is your new text – up to 30 characters, full stop (dot) or
comma cannot be used in the text, spaces are allowed
Example: MASTER TXT 01,LOCK PLEASE
By changing text numbers 01 to 16, you will modify the control SMS
instructions. This allows you to customize the remote control of the car.
You can also make your own password part of the instruction to increase
the security of the mobile phone remote access.
10.1 SMS text table
zz Factory default text zz Factory default text
SMS commands:
34 Wireless detector
01 AM 35 Current detector
02 DM 36 Telephone 1
03 IMO 37 Telephone 2
04 UNIMO 38 Telephone 3
05 STATUS 39 Telephone 4
06 HELP 40 Telephone - UC
07 CREDIT 41 Telephone - MC
08 DIAL 42 Remote controller
09 HF
Status information:
10 LOCATOR 50 Car alarm reports:
11 MC 51 Status:
12 UC 52 Armed
13 DIP 53 Disarmed
14 TEL 54 Ignition key ON
15 LEARN RC 55 Ignition key OFF
16 LEARN JA 56 Engine is blocked
17 SIREN 57 Engine is unblocked
18 SET 58 No alarm
Events:
59 Alarm timeout
20 Alarm 60 Low accumulator voltage
21 Alarm canceled by a user 61 Power failure
22 Fire alarm 62 Power recovery
23 Tamper alarm 63 Time:
24 Disarming 64 Low battery voltage
25 Arming
Confirmation SMS:
26 Low battery voltage 70 Command accepted
27 Engine is blocked 71 Command syntax error
28 Engine is unblocked 72 New MC code:
Source:
73 New UC code:
30 Ignition key 74 Reset
31 Door contact 75 Registered phone number:
32 INP1 activation 76 Credit:
33 INP2 activation 77 LEARN mode, enrolled
The gray texts are not available in mode 3.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron CA-1202 - mode 3 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron CA-1202 - mode 3 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,5 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Jablotron CA-1202 - mode 3

Jablotron CA-1202 - mode 3 Gebruiksaanwijzing - English - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info