ELECTRONIC 7-DAY WATER -
HEATER TIME SWITCHES
MODELS EH10 AND EH40
WITH BATTERY CARRYOVER
MAN
AUTO
PROG
RUN
TIME
SET
ON
OFF
EVENT
DAY
HOUR
MIN
LOAD
RESET
BA
TTERY
OWNER/INSTALLER INSTRUCTION MANUAL
ATTENTION: READ CAREFULLY BEFORE ATTEMPTING
TO INSTALL YOUR INTERMATIC TIME SWITCH. FAIL-
URE TO COMPLY WITH INSTRUCTIONS COULD
RESULT IN PERSONAL INJURY AND/OR PROPERTY
DAMAGE! RETAIN FOR FUTURE REFERENCE.
MANUAL (MAN) - AUTOMATIC (AUTO)
(See Fig. 1)
MANUAL: Bypasses your program completely; timer
will not resume program until you return switch to
AUTO mode position.
AUTOMATIC: For automatically switching at ON/OFF
times; accurate to-the-minute.
PROGRAM (PROG) - RUN - TIME SET
PROGRAM: Use this position when programming.
RUN: Use this position for normal operation. Be sure to
return to RUN after setting time and program.
TIME SET: Use this position to set day and time of day.
ON/OFF - EVENT (the large push button) - Serves a dual
purpose
EVENT:
Used for programming (active only when switch
is set at PROG)
ON/OFF: Override (active only when switch is set at
RUN); turns load ON if already off or OFF if already on.
Timer automatically resumes program cycle only when
slide switch is in AUTO. Note that this button is also
accessible without opening the enclosure.
SPECIFICATIONS:
Clock Voltage - Model EH40 - 240V. A.C., 50/60 Hz
EH10 - 120V. A.C., 50/60 Hz
Power Consumption - EH10 - 1.0 W. Max. EH40 - 3.0
W. Max..
Contact Configuration - EH10 (SPST) Single pole-single
throw model-EH40(DPST) Double pole-single throw model
Switch Rating (Per Pole) -
• 30 amp inductive/resistive - 120-240V. A.C., 60 Hz
• 1 H.P. 120V. A.C., 60 Hz.
• 1-1/2 H.P. 240V. A.C., 60 Hz.
• 5 amp tungsten, 120-240V. A.C., 60 Hz.
Set Points (Events) - 12 total (6 ON/6 OFF) - Can be
assigned in any combination to weekdays, weekend days,
daily or weekly operation providing up to a maximum of 84
weekly operations (42 ON/42 OFF).
Battery Powered Clock Operation - 3 years minimum,
AA industrial grade alkaline supplied with time switch.
Minimum ON/OFF Time - 1 Minute
Maximum ON/OFF Time - 6 days 23 hours 59 minutes
Shipping Weight - 2.37 Lbs. (1.05 Kg)
Case - Drawn steel, 7-3/4” (19.7 cm) high, 5” (12.7cm)
wide, 3” (7.6 cm) deep; gray finish with lockable spring
hasp, clear see-through viewing window and external over-
ride.
Knockouts - Combination of 1/2 - 3/4” (one on back and
each side, two on bottom)
Wire Size - AWG #10 through #18
GENERAL SAFETY INFORMATION:
WARNING: DISCONNECT THE POWER TO THE TIME
SWITCH AND THE LOADS BEFORE INSTALLING THIS
TIME SWITCH.
1. Mount the time switch in the desired location using the
three mounting holes which are provided. Mount the
time switch at eye level, if possible, providing
sufficient room to the left of the enclosure for the
cover to swing open fully. (See Fig. #2). The time switch
mechanism does not need to be removed from the
enclosure to mount the time switch since the top mount-
ing hole is a slotted type mounting hole. Secure a screw
or other fastener at eye level. The head of the screw
of fastener should be slightly larger than the narrow
portion of the slotted hole to ensure that the time switch
is securely held in place. The remaining two mounting
holes provide a means to secure the time switch.
2. If you do remove the mechanism, refer to Figure #3 and
remove the mechanism from the case by depressing
the catch at the top of the case and pulling out.
CAUTION: DO NOT TOUCH THE CIRCUIT
BOARD COMPONENTS SINCE STATIC DISCHARGE
COULD DAMAGE THE MICROPROCESSOR.
3. Replace the mechanism in the case if it has been
removed, making sure to engage ribs at sides of
mechanism between ears at sides of case before
snapping in place.
4. Lift the left side of the insulator off of the retaining post
and pivot it up and away to expose the terminal
screws.
5. Strip the supply and load wires by removing 1/2 inch of
insulation.
DO NOT USE ALUMINUM WIRE. Insert
the wire ends under the proper terminal plates and
tighten the screws firmly. Use any size wire,
AWG #10 through #18. Connect ground wire to
grounding terminal at bottom of case.
6. Replace the plastic insulator.
7. Follow instructions for battery installation. Be sure that
the battery is functioning properly. This can be checked
by seeing that the display is visible. If the display
has scrambled information, check to be sure that
the polarity orientation of the battery is as shown on
the cover label, then press the RESET switch and hold
for at least two seconds. Note that the battery can
easily be replaced without removing the time
switch mechanism or field wiring. Simply press in and
downward (in the direction of the arrow) on the
battery cover which is identified with the word “Battery”.
It is recommended that the battery be replaced with a
“AA” industrial grade alkaline cell at two to three
Fig. 3
Fig.2
®
Fig.1
Mounting Holes
Knockouts
Ground
Terminal
Snap Out Catch
Tilt Top Forward
Lift Up
To
Remove
http://waterheatertimer.org/How-to-wire-EH40-hot-water-heater-timer.html
________________________________________________________________
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Intermatic EH10 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Intermatic EH10 in de taal/talen: Engels, Frans, Spaans als bijlage per email.

De handleiding is 0,29 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info