496150
2
Verklein
Vergroot
Pagina terug
1/4
Pagina verder
Mains supply and safety
Mains Supply: The mains operating voltage of all Audiolab units is
shown on the rear panel. If this does not match the voltage in your area,
consult your dealer.
The mains supply fuse is located on the rear panel of the unit. If it has
broken, check for any obvious cause before replacing the fuse with one of
the correct rating and type. The fuse values are:
220 - 240V (UK, Korea, etc.) T 2.5AL 20mm Slow Blow
100 - 120V (USA, Japan, etc) T 4.0AL 20mm Slow Blow
The fuse is located in a slide-in
carrier which also contains a spare
fuse. The fuse carrier can only be
pulled out after the IEC power cord is
unplugged. When the carrier is
opened the first fuse to be seen is the
spare fuse. Remove and safely
dispose of the fuse with the blown
link before replacing it.
Class II construction double insulated. This product must not be
connected to earth.
Power Cord: An AC power cord is normally supplied with a mains plug
suitable for your area. If you have any doubts, consult your dealer about
obtaining a suitable power cord.
Important notice to UK users
The appliance cord is terminated with a UK approved mains plug fitted
with a 5A fuse. If the fuse needs to be replaced, an ASTA or BSI approved
BS1362 fuse rated at 5A must be used. If you need to change the mains
plug, remove the fuse and dispose of this plug safely immediately after
cutting it from the cord.
Connecting a Mains Plug
The wires in the mains lead are coloured in accordance with the code:
Blue: NEUTRAL; Brown: LIVE:
As these colours may not correspond to the coloured markings identifying
the terminals in your plug, proceed as follows:
The BLUE wire must be connected
to the terminal marked with the
letter N or coloured BLUE or
BLACK. The BROWN wire must be
connected to the terminal marked
with the letter L or coloured
BROWN or RED.
2.5A FUSE
BS 1362
BROWN
(Live)
BLUE
(Neutral)
Fuse Carrier
IEC Mains Connector
Use only attachments/accessories specified by the manufacturer.
Use only with a cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms or when unused for long
periods of time.
Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have
fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
Warning: To reduce the risk of fire or electrical shock, do not expose this
product to rain or moisture. The product must not be exposed to dripping
and splashing and no object filled with liquids such as a vase of flowers
should be placed on the product.
No naked flame sources such as candles should be placed on the
Read these instructions.
product.
Keep these instructions. In the event that you pass the product to a third
Caution: Changes or modifications not expressly approved by the
party this instruction manual should be provided along with the product.
manufacturer could void the user's authority to operate this device.
Heed all warnings.
This equipment has been tested and found to comply with the limits for a
Follow all instructions.
Class B digitial device, pursuant to part 15 of the FCC rules. These limits
Do not use this apparatus near water.
are designed to provide reasonable protection against harmful
Clean only with dry cloth.
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
Do not block any ventilation openings.
accordance with the instructions, may cause harmful interference to radio
Install in accordance with the manufacturer's instructions.
or television reception, which can be determined by tuning the equipment
Do not install near any heat sources such as radiators, heat registers,
off and on, the user is encouraged to try to correct the interference by one
stoves, or other apparatus (including amplifiers) that produce heat.
or more of the following measures:
Do not defeat the safety purpose of the polarized or grounding type plug.
Re-orientate or re-locate the receiving antenna. Increase the separation
A polarized plug has two blades with one wider than the other. A
between the equipment and the receiver. Connect the equipment into an
grounding type plug has two blades and a third grounding prong. The
outlet on a circuit different from that to which the receiver is connected.
wider blade or the third prong are provided for your safety. If the provided
Consult the dealer or an experienced radio/TV technician for help.
plug does not fit into your outlet, consult an electrician for replacement of
the obsolete outlet.
Important Note: The batteries supplied with this unit should be treated
Protect the power cord from being walked on or pinched, particularly at
with care and not punctured or damaged. Used batteries should be
plugs, convenience receptacles, and the point where they exit from the
disposed of in full conformity with recycling regulations in your area.
apparatus.
NEVER dispose of batteries in a fire or in the general rubbish.
CAUTION!
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ADVERTISSEMENT: RISQUE DE CHOC ELECTRIQUE-
NE PAS OUVRIR
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER
NO USER-REMOVEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
1: Statutory & Safety Information
Rated Output Power Headphone Output
60 W (18 dBW) per channel into rated load impedance (8 Ohms)
Output impedance: 330 W
with both channels driven
(Suitable for headphones 8 W-2 kW impedance)
Record Output
Inputs
VIDEO OUT, TAPE 1 OUT, TAPE 2 OUT:
CD, TUNER, AUX, VIDEO, TAPE 1, TAPE 2: 125mV/20kW IHF
Output impedance: 1 kW.
POWER AMP: 782 mV/47 kW
Gain from input to record output 0 dB (x1)
Gain
Muting
PRE-AMP: 9dB@ 1 kHz
Muting controlled manually or automatically
POWER AMP: 29.0 dB @ 1 kHz.
Accessories Supplied
Signal To Noise Ratio
AC Power Cord
CD, TUNER, AUX, VIDEO, TAPE 1, TAPE 2:
Instruction Manual
Better than 80dB(IHF, rel. 0.5 V pre-amp output)
8000RC Remote Control with 2 x AA batteries
POWER AMP: better than 80dB(IHF, rel. O dBW)
Colour
Frequency Response
Silver
CD, TUNER, AUX, VIDEO, TAPE 1, TAPE 2 and POWER AMP:
Operating Temperature Range
20 Hz-20 kHz ±0.5 dB: 1 Hz-65 kHz -3 dB.
10-35 °C
Total Harmonic Distortion & Noise
Power Requirements (Depending on Region)
Less than 0.07 %
50-60Hz 100 V, 110-120 V, and 220-240 V models available
Channel Balance
Maximum Power Consumption: 440 VA
Within 1 dB
Dimensions (WXHXD)
Channel Separation
445x74x335 mm - including feet, terminals and controls
Better than 60 dB @ 1 kHz any input
445 x 64 x 302 mm- excluding feet, terminals and controls
Crosstalk
Weight
Better than 80 dB @ 1 kHz
Net: 7.4 kg
Polarity (phase)
Shipping: 8.8 kg
Non-inverting for all inputs and outputs
Audiolab reserves the right to alter design and specification
Pre-amp Output
without notice. Specification may vary for different countries.
PRE OUT 1 and PRE OUT 2: Output Impedance 100 W
Audiolab is a member of the International Audio Group.
Maximum Output >7.3 V RMS
6: Specifications 8000S
Power Amplifier Protection Circuits
Short Circuit Protection: If the output terminals are connected together or there
is a short caused by a faulty speaker or connecting lead, the amplifier will mute and
un-mute until the fault condition is removed.
DC Offset Protection: If there is an internal or external fault which may cause DC
voltage to be presented to the loudspeaker, the amplifier will mute and stay muted
until the fault is removed.
Thermal Protection: If the amplifier is driven excessively for long periods, or the
output devices are pushed beyond their safe operating area, the amplifier will
switch off and then switch back on again when it has cooled down.
In all cases, if the amplifier does not respond to remedial action, consult your dealer.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Audiolab 8000S bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Audiolab 8000S in de taal/talen: Engels als bijlage per email.

De handleiding is 2 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info