785266
1
Verklein
Vergroot
Pagina terug
1/1
Pagina verder
BlueSolar PWM Light Charge Controller 12/24V
(with light turn-off timer)
Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands
Phone: (+31) (0)36 535 97 00 / Fax: (+31) (0)36 535 97 40 / www.victronenergy.com / e-mail: sales@victronenergy.com
Revision : Rev 07
Date : 02-05-2017
1. DESCRIPTION
Programmable load output with lighting control mode.
Three stage battery charging (bulk absorption float).
Protected against over current.
Protected against short circuit.
Protected against reverse polarity connection of the battery or solar array.
Low voltage load disconnect.
Easy to set up thanks to two digit seven segment display.
2. INSTALLATION
The display will show a ‘’12’’ if the Controller detects a 12V battery, and a “24” if
it detects a 24V battery
Do not exceed Solar and Load ratings
3. LED INDICATORS
Green LED:
Off: No sunlight or not enough sunlight. Charger off.
Fast flashing: Bulk charge.
On: Absorption charge.
Slow flashing: Float charge.
LED=Green: battery fully charged (> 12,7V)
LED=Orange: battery ok (12,4V - 12,7V)
LED=Red: battery low (11,2V - 12,4V)
LED=Flashing Red: battery fully discharged (< 11,2V)
(load output cut off level: 11,2V)
LED=ON: load output is on.
LED=OFF: load output is off.
LED=Slow flashing: Overload.
LED=Fast flashing: Short Circuit
Please note:
1. The load output will cut off in case of over load or short circuit. The load output
will attempt to restart after 30 seconds.
2. After over discharge, the load will reconnect automatically when the battery is
recharged to 13,1V / 26,2V.
3. After over discharge, the load can be reconnected manually by pressing the
on/off push button, if the battery voltage exceeds 12,6V / 25,2V.
4. SETTING THE LOAD OUTPUT
4.1 Settings
4.2 Settings description
0 Charger only
The load output is switched off permanently.
1-13 Light control + delay
The load output automatically turns on after sunset (array voltage < 4V) and the
built-in timer starts counting.
When the timer reaches the set time, or when the low voltage limit is reached,
the load output will turn off.
H Manual
The load output can be turned on and off manually with the push button.
(low voltage shutdown remains active)
C Load output controlled by battery voltage only
Load disconnect and load reconnect will be based only on battery voltage, see
section 3
L Dusk to dawn mode
Turn on delay (array voltage < 4V): 10 seconds.
Turn off delay (array voltage > 4V): 1 minute.
No timer function.
d Debug mode
Same as L mode but without delay of 10s/1min
5. SPECIFICATIONS
BlueSolar PWM-Light 12/24-5 12/24-10 12/24-20 12/24-30
Battery Voltage 12/24V with automatic system voltage detection*
Rated charge current 5 A 10 A 20 A 30 A
Recommended solar array
36 cell for 12 V / 72 cell for 24 V
Automatic low voltage load
disconnect Yes
Maximum solar voltage 28 V for a 12 V system and 55 V for a 24 V system (1)
Self-consumption < 10 mA
Overload protection
Shut down after 60 s in case of 130% load
Shut down after 5 s in case of 160% load
Short circuit: immediate shut down
Grounding Common positive
Operating temp. range -20 to +50°C (full load)
Humidity (non condensing) Max 95 %
Settings
Charge voltage 'absorption' 14.2 V / 28,4 V
Charge voltage 'float' 13.8 V / 27,6 V
Load disconnect 11,2V / 22,4V
Load reconnect 12,6V / 25,2V (manual)
13,1V / 26,2V (automatic)
Enclosure
Protection class IP20
Terminal size 5 mm² / AWG10
Weight 0,13 kg 0,15 kg
Dimension (h x w x d) 70 x 133 x 33,5 mm (2.8 x 5.3 x 1.3 inch)
Mounting Vertical wall mount Indoor only
Humidity (non condensing) Max. 95%
Operating temperature -20°C to +50°C (full load)
Cooling Natural convection
Standards
Safety IEC 62109-1
EMC EN 61000-6-1, EN 61000-6-3, ISO 7637-2
1) For 12V use 36 cell solar panels
For 24V use 72 cell solar panels
or 2x 36 cell in series
2) The controller switches to the lower float
voltage level 2 hours after the absorption voltage
has been reached.
Whenever the battery voltage becomes lower
than 13 V, a new charge cycle is triggered.
0 Load output permanently off 9
Load output turned on during 9
hours after sunset
1
Load output turned on during 1
hour after sunset
10
Load output turned on during 10
hours after sunset
2
Load output turned on during 2
hours after sunset
11
Load output turned on during 11
hours after sunset
3
Load output turned on during 3
hours after sunset
12
Load output turned on during 12
hours after sunset
4
Load output turned on during 4
hours after sunset
13
Load output turned on during 13
hours after sunset
5
Load output turned on during 5
hour after sunset
H Manual load control
6
Load output turned on during 6
hours after sunset
C
Load output controlled by battery
voltage only
7
Load output turned on during 7
hours after sunset
L Dusk to dawn mode
8
Load output turned on during 8
hours after sunset
d Debug mode
Always connect the batteries first, in order to allow the
Controller to recognize system voltage
Use a 12V (36 cells) solar array for a 12V battery system.
Use a 24V (72 cells) solar array for a 24V battery system.

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Victron BlueSolar PWM-Light 12 24V-30A bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Victron BlueSolar PWM-Light 12 24V-30A in de taal/talen: Engels als bijlage per email.

De handleiding is 0.09 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info