558012
1
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
Top portion of the LCD
- scrolls through line voltage, line
current, max current, wattage, max
wattage and overload warning mode
EM100
electronic energy meter
OWNERS
MANUAL
Congratulations on your
purchase of a UPM energy
meter. Please take the
time to read and
understand this manual so
you can begin to enjoy the
energy saving benefits this
product has to offer.
FEATURES
! Overload warning
! Energy monitor and
energy consumption
tracking
! Maximum current and
wattage readings
! Energy cost calculation
! Energy usage time
GETTING STARTED
battery installation
OVERLOAD WARNING
setting the overload parameter
display
1
2
1
2
remove the battery cover
from the back of the unit
place 2 button cell batteries between
terminals observing proper polarity
then replace cover
TECHNICAL SPECIFICATIONS
Ratings: 120 V AC, 15 A
Max Load: 1800 W
1
4
2
5
Press OVERLOAD
Toggle between overload in wattage (W)
or current (A) using or
Press OVERLOAD
Adjust the desired parameter value
using or . Press OVERLOAD to
set each digit.
3
MAX
V
A
W
KWh
PM
$
TOTAL
PRICE/KWh
Overload indicator
Wattage (Watt)
Current (Ampere)
Voltage (Volt)
Maximum load
Energy monitor display
Total energy consumption
Total energy cost
Price of energy
Energy usage time
The overload warning function allows you to safeguard against exceeding
a preset load capacity. The ‘overload’ indicator will flash and the alarm
will sound continuously to warn you in the case of an overload.
Select overload warning mode using
4
2
53
1
*
ATTENTION:
This energy meter is NOT a surge protector.
OVERLOAD - overload set
1
2
- scrolls through total energy, total
cost, and energy price mode
3
button placement
PRICE - price set
4
1
2
3
4
Voltage (V) Current (A) Maximum Current (A)
Overload Warning Maximum Wattage (W) Power (W)
Middle portion of the LCD
Total Energy (kWh) Total Cost ($) Energy Price ($/kWh)
ENERGY CONSUMPTION AND COST
The price setting function allows you to input the electrical rate in $/kWh to
calculate the total cost of energy consumption.
setting the price of energy
1
2
Press PRICE
Adjust the value using or .
Press PRICE to set each digit.
3
Select energy price mode using
3
2
3
1
*
total energy used and total cost
Press to view total energy used and total cost incurred
1
3
1
Modes are arranged in a circular pattern:
Total Energy - Total accumulated energy used by the load (kWh)
Total Cost - Total accumulated energy cost incurred by the load ($)
based on the user-set price ($/kWh) and total energy (kWh)
ENERGY MONITOR
Press to view the line voltage, line current, max current, wattage
and max wattage readings; displayed in the top portion of the LCD
1
Line Voltage - voltage (V)
Line Current - current (A)
Max Current - max current (A)
Wattage - real power (W)
where power = voltage x current x power factor
Max Wattage - maximum wattage (W)
MIDDLE PORTION OF LCD DISPLAY
TOP PORTION OF LCD DISPLAY
TOP PORTION OF LCD DISPLAY
*
Modes are arranged in a circular pattern:
1
to clear max load
Press and hold and OVERLOAD
together for 3 seconds to clear max
current and max wattage readings
1
The bottom portion of the LCD display keeps track of the accumulated
energy usage time - “power on” time.
2
3
2
1
ENERGY USAGE TIME
BOTTOM PORTION OF LCD DISPLAY
Beep indicates that max current and
max wattage readings are cleared
Press and hold and PRICE together
for 3 seconds to clear energy usage
time and total energy used (kWh)
1
2
Beep indicates that energy usage time
and total energy used are cleared
2
1
to clear energy usage time/total energy used
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw UPM EM100 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van UPM EM100 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,65 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info