559312
1
Verklein
Vergroot
Pagina terug
1/1
Pagina verder
QUICK GUIDE - OptiMate 6
The QUICK GUIDE is a brief description of LED indications and their meaning as they occur through-out the program. For detailed voltage
and current values refer to the full instruction set. The LED numbers are referenced according to the LED panel illustration below.
Following connection to AC power: LED #1 lights. LED #1 will dim (reduce intensity) during ECO mode.
Incorrect reversed connection to the battery: LED #2 lights with LED #1.
WHEN CHARGING A BATTERY:
If
the battery is fl at with voltage measuring at least 2V
OR a standard wet cell battery is less than 80% charged
OR a sealed AGM battery is less than 60% charged
LED #3 lights FULL ON indicating the 3 stage recovery / desulfation mode has engaged.
Charge time: Max. 2 hours, Min.15 minutes.
TURBO: If after 5 seconds LED #3 fl ashes (on-off-on) the TURBO (high voltage desulfation) mode has engaged, indicating the battery's
level of sulfation is high. LED #8 will light once the battery accepts minimum charge current, confi rming start of recovery.
STANDARD: LED #8 immediately lights (together with LED #3) indicating the battery is lightly sulfated and is accepting charge current at the
16V limited level. NOTE: This may also occur if the neglected battery remains in the vehicle and the connected circuitry is drawing current.
For best results when attempting to recover a neglected battery, remove from the vehicle, inspect and then charge.
PULSE: During the fi nal 15 minute stage of recovery LED #9 and then LED #10 should light or pulse together with LED #8. NOTE: A healthy
deep discharged battery may immediately advance to this stage.
LED #4 lights FULL ON indicating BULK charge mode has engaged Charge time: Max. 48 hours (less time in RECOVERY mode)
If a standard wet cell battery has an initial charge higher than 80%
OR a sealed AGM battery has an initial charge higher than 60%
OR a battery has suffi ciently recovered during RECOVERY desulfation mode
LEDs #8, 9 and 10 may come on through-out BULK charge stage as current is varied by the AMPMATIC program to ensure the most
complete charge before advancing. Once the battery voltage has risen to 14.3V, indicating an almost fully charged battery, then
LED #4 fl ashes to indicate PULSE ABSORPTION - CELL BALANCING - VERIFICATION multiple charge mode has
engaged. Charge time: Maximum 48 hours less time in RECOVERY and BULK mode OR minimum 15 minutes.
PULSE ABSORPTION - CELL BALANCING 10 minute period: Charge current is delivered during which the voltage is carefully controlled to
remain below 14.4V. Maximum charge current depends on the battery condition, it is expected to reduce with each pulse cycle.
VERIFICATION - Following each 10 minute period battery condition is verifi ed.
If the program: determines that the battery needs further charging, it will return for a further 10 minute period of charging
OR determines that the battery does not require further charging then after 5 minutes it will proceed to the TEST mode
OR has detected a battery with internal damage, it will immediately proceed to TEST mode.
LED #5 fl ashes when TEST mode engages. During the fi rst 30 minutes the battery's initial state of health is determined. If LEDs #6
and/or 7 light the battery is in poor health or could not be recovered. The program will proceed directly to MAINTENANCE MODE.
A battery with a good state of health, indicated by LED #5 or LED #5 & 6 fl ashing through-out the initial 30 minute period, advances to the
EXTENDED (12 HOUR) TEST during which a more accurate assessment is made. EXTENDED TEST LED fl ash mode: on-on-OFF-on-on-OFF.
NOTE: Even a partially damaged battery may hold charge for a short period immediately following charging, but will revert to it's actual
condition after not receiving charge for at least 12 hours). See page 7 for possible results.
LED #5, 6 and /or 7 light FULL ON when maintenance mode engages for a period of 12 hours. The TEST RESULT is indicated
by LEDs #5, 6 and 7. During 30 minutes of each hour OptiMate's unique tested and proven maintenance charge is delivered to extend
battery life. During the alternative 30 minutes no charge is delivered, allowing the battery electrolyte to settle, which greatly reduces loss of
electrolyte in wet cell batteries. The maintenance mode alternates with the TEST mode until the battery is disconnected.
27
FINAL
TURBO
AMPS
1
3
4
2
5
6
7
LED #10
-
5A charge current
LED #8
-
0.4A charge current
LED #9
-
Current between
0.4 - 5 Amp per
Ampmatic control
LEDs #5, 6 & 7
Flashing: Testing
(no charge delivered)
Single flash: initial test
Double flash: 12 hour test
Full on: Maintenance
charge is delivered and
TEST result is displayed
LED #1 -
AC power present
LED #2 -
Battery connected
in reverse polarity
LED #3
-
Full on: Low voltage low current or pulse
desulfation
Flashing: Turbo high voltage desulfation
LED #4
-
Full on: Bulk Charge
Flashing: Final Charge & verification

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Tecmate OPTIMATE 6 TM 180 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Tecmate OPTIMATE 6 TM 180 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,1 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Tecmate OPTIMATE 6 TM 180

Tecmate OPTIMATE 6 TM 180 Gebruiksaanwijzing - Nederlands, Deutsch, English, Français, Italiano, Português, Espanõl, Svenska - 44 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info