4. Fuel Injection System
4-58
Comprehensive Maintenance List
No.
Maintenance
Project
Testing Procedures Test items Determine benchmarks Fault reasons
1
Power and
voltage
Use meter direct
measurement battery voltage
Use diagnosis tool detection
of battery voltage
Battery voltage ● Battery voltage = 10V Above Battery electricity
Battery connector loose
Harness circuit opening
ECU coupler not connected
properly
2
Fuel
pressure
Use fuel pressure gauge,
connected in series between
the injector and the Pressure
Regulating Valve
Main switch ON, but not
start engine
Check fuel pressure
Start engine (idle)
Check change of the fuel
pressure
throttle several rotation
check to the change of fuel
pressure again
Open the main
switch, but do not to
start the engine of
pressure
Pressure in idle
Rotating throttle,
situation of pressure
changes
● Open main switch, but do not
start the engine of pressure:
= 250kPa
(Stable value)
● Idle state:
pressure = 294±6kPa
(Beating situation from top to
bottom)
● rotation throttle moment:
pressure = 294±6kPa (Slightly
beating)
Fuel not enough
Security switch not disarm
Fuel pump relay fault
Fuel pump fault
Injector fault
ECU fault
3
Ignition state
The spark plug removed from
the cylinder head, but the
power lines still ring
Start engines or use for the
diagnosis tool of output View
spark plug ignition conditions
Spark plug
specifications
Whether the spark
plug ignition
Spark plug sparks
whether it is normal
strength
Specifications: NGK-CR8H
● Ignition conditions:
With traditional engines found
ways
Spark plug fault
Roll over sensor fault
ECU No. 5 pin fault
Ignition coil fault
Crankshaft position sensor
fault
4
Engine
vacuum
Diagnosis tool to detect the
use of
Manifold pressure of
diagnosis tool
Manifold pressure
=32~38kPa
Valve clearance abnormal
Intake system leak
5
Injection
state
The injector removed from
the throttle body, but not
dismantle pipeline
Main switch ON, but not
start engine
Investigation the injector it’s
leaking fuel?
Once again start engines or
use for the diagnosis tool of
output function
Check injector fuel injection
and the injection situation
Open the main
switch, but did not
start engine the
injection situation
Injector state when
start
Not started, injector not
leaking fuel
In started, the injection state
must show fan shape
Security unit is configured
not disarm
Fuel pump relay fault
Fuel pump fault
Injector fault
ECU fault
6
Closed -
loop control
system
Use of diagnostic tool
observation O2 Sensor
voltage changes
● Stable condition,
sensor voltage
variation (Idle
continued 5 minutes
later to
measurement)
● Idle stable condition: O2
Sensor voltage = 50 ~ 200mV
(Show from top to bottom
beating phenomenon)
● O2 Sensor fault
● ECU fault
7
Fault Code
Detection
Use of the diagnosis tool
existing fault-detection code
or historical Fault Code
Elimination of the
implementation of fault
codes, check can be
eliminated
Once again start engine
Check fault is it happen
again
● Diagnosis tool of the
fault code is it can be
eliminated
● Start again, the fault
is it will happen again
● Without any residual Fault
Code
● If residual Fault Code,
according to the "Fault Code
Maintenance Form"
implementation of
troubleshooting
throttle position sensor fault
● Engine temperature sensor
fault
● Intake temperature sensor
fault
● Manifold pressure sensor
fault
● O2 Sensor fault
● Crankshaft position sensor
fault
● ECU fault
● Roll over sensor fault
Notes: 1.Fuel pressure gauge connected between the fuel tank and injector, open the main switch to
repeatedly shut down, fuel system makes pressure stability.
2. Injector and injector cap tightly by hands, fuel spills should not be the case
To this chapter contents
101

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Sym-Maxsym-400

Zoeken resetten

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sym Maxsym 400 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sym Maxsym 400 in de taal/talen: Engels als bijlage per email.

De handleiding is 10,63 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Sym Maxsym 400

Sym Maxsym 400 Gebruiksaanwijzing - Nederlands - 37 pagina's

Sym Maxsym 400 Gebruiksaanwijzing - English - 34 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info