565043
4
Verklein
Vergroot
Pagina terug
1/8
Pagina verder
The home technology brand for the entire house. More information at www.sygonix.com
These operating instructions are a publication by Sygonix GmbH, Nordring 98a, 90409 Nürnberg (www.sygonix.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, micro lming, or the capture
in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is
prohibited. These operating instructions represent the technical status at the time of printing. Changes in techno-
logy and equipment reserved. © Copyright 2012 by Sygonix GmbH.
Nr. 33983R - Version 11/12Legal notice
Installation and Connection
Pay attention to the chapter “Safety Instructions” and the chapter
“Preparations for Connection and Installation”.
First, switch off the mains voltage to all poles.
Remove the wall mounting plate from the back, by removing the two xing screws
on the lower edge.
You will nd the temperature sensor on the rear of the
room temperature regulator, which is attached by two
spring clips (see picture right).
If desired, you can replace these internal sensors with
an external sensor (this is not included in the room
temperature regulator package; it can be ordered se-
parately).
Pull the two-poled spring clips from the contact pin, to
attach easily, and then loosen the two screws, which
attach the sensor and take out the sensor. Keep this
for later use.
Next attach the two wires of the external sensor to the screw clips. The polarity is not
important here.
Finally, insert the two-poled screw clips back onto the contact pin.
Place the connecting line to the external sensor in a suitable way: place the sensor
according to your needs (for example, for in- oor heating near the ground).
The wall mounting plate can be directly mounted using the two mounting holes with
two screws in a ush socket (hole/screw separation 60 mm).
Depending on the wall surface, the wall mounting plate can also be secured to the
wall with appropriate screws and wall plugs.
Pay attention when drilling and and tightening the screws that no cables or
pipes are damaged!
Before installation, run the power cable and the connection cables to the heater
through the opening in the wall mounting plate.
Connect the mains cable using the connections “L” (phase, brown cable) and “N”
(neutral line, blue cable).
Connect the cable to the screw clamps “NO”, “COM” and
“NC”. The relay operates potential-free.
Pay attention to the maximum contact load capacity; see
chapter “Technical Data” and the operating instructions for
the device that is to be controlled by the thermostat to see
how to carry out the wiring.
“NC” Breaker (NC = “normally closed” = in the rest state, the contact is closed)
“NO” Maker (NO = “normally open” = in the rest state, the contact is open)
“COM” Centre contact
Set the thermostat on the mounting plate and then attach it used the screws remo-
ved at the start.
Make sure the thermostat is attached securely to the wall mounting plate.
Lastly, turn on the mains voltage again.
Function
Use the knob to set the desired temperature. If the relay is activated, the blue control
LED lights up.
Example: The room temperature is +20 °C; you want a temperature of +25 °C.
Turn the knob so the arrow points to the position “25”.
The relay switches on (connections “COM" and “NO” are connected); the
blue control LED lights up.
At a temperature of +25.5 °C (set temperature value plus switch tempera-
ture difference), the relay is deactivated and the blue control LED goes out.
If the temperature falls below +24.5 °C (set temperature minus switch tem-
perature difference), the relay is activated again and the blue control LED
lights up.
The switch temperature difference of 0.5°C prevents switching a connected heater on
and off too frequently.
Tro u b les h o oti n g
The temperature variation in the room is too great (approx. 5 - 8 °C)
The neutral wire and the phase were switched during the connection of the thermostat.
The knob must be set higher than the desired room temperature
The neutral wire and the phase were switched during the connection of the thermostat.
The your room heater's thermal output is too low.
The thermostat is in uenced by external temperature in uences (e.g., by sunlight,
proximity to heaters or electrical devices).
The knob must be set lower than the desired room temperature
The thermostat is installed in the wrong place, e.g. behind a curtain, near a door or
on an exterior room wall.
The room does not get warm
The thermostat or the switch contact is dirty. Turn off the mains voltage and carefully
blow out the thermostat, e.g. with compressed air.
Multiple thermostats (e.g. for two rooms) are connected in series.
Slow reaction to the set temperature
In well-insulated buildings, it can take a long time for the room temperature to fall.
On the other hand, it can take a long time for the temperature to rise in poorly insu-
lated buildings and with cold exterior walls.
In any case, oor heaters react very slowly to the temperature setting.
Disposal
Dispose of an unserviceable product in accordance with the relevant statu-
tory regulations.
Technical Data
Operating voltage: 230 V/AC, 50 Hz
Contact load capacity 10 (4) A
Switching temperature difference: 0.5 °C
Accuracy : +/-1 °C at +20 °C
Temperature range: +5 °C to +30 °C
Ambient air humidity: 0 - 95% relative air humidity, not condensing
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sygonix TX 1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sygonix TX 1 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 0,27 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info