675168
6
Verklein
Vergroot
Pagina terug
1/12
Pagina verder
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2016 by Conrad Electronic SE. 15621Q1 *1428341_V3_1116_02_VTP_m_en
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2016 by Conrad Electronic SE. *1428341_V3_1116_02_VTP_m_4L
Timer function
Set-up (and use) is only possible if plug-in thermostat is switched on by the „ “ key
and the temperature is displayed in the lower row.
Selecting operating mode
Refer to the corresponding chapter of these operating instructions.
Switching the timer on/off
In order to switch the timer on or off, briey press the „P“ key.
Once the timer is switched on, the symbol „
“ will appear on the display bottom left, and
the timer time bottom right.
Setting timer time and temperature limit
Switch on the timer rst as described above.
Hold the „P“ key for approx. 3 seconds until the timer time starts ashing.
Set the timer time using the „+“ or „-“ key (1....99 hours). For quick adjustment, press and hold
down the corresponding key for longer.
Briey press the „P“ button. The temperature limit value will ash.
Use the „+“ or „-“ key to set the temperature limit value. For quick adjustment, press and hold
down the corresponding key for longer.
In order to quit the set-up mode, briey press the „P“ key. Alternatively, wait for about 10 sec-
onds, without pressing any key. The timer time will stop ashing.
Function of the timer
Example:
The room temperature is e.g. 19 °C and you set the temperature of 25 °C and duration of
5 hours via the timer.
After the start of the timer, the thermostat will control the connected appliance according to the
measured room temperature for the next 5 hours.
Timer operation can be paused and resumed by the „
“ key.
If the timer functions should be terminated, switch off the timer by the „P“ key as described
above.
After expiry of the timer time, the plug-in thermostat will turn off the connected appli-
ance.
If the plug-in thermostat should operate in normal mode after that, switch the ther-
mostat („OFF“ will appear on display) off and on again.
Resetting the plug-in thermostat
To reset the plug-in thermostat to factory settings, press briey the recessed „Reset“ key (on
the right below the „ “ key) e.g. by a toothpick.
Function Factory settings
„COOL“ = cool mode 25 °C
„HEAT“ = heat mode 20 °C
Timer 2 hours
Heating Mode: 16 °C
Cooling Mode: 28 °C
Care and Cleaning
Before cleaning the product, disconnect the appliance from the plug-in thermostat. Disconnect
then the plug-in thermostat from power supply by pulling it out of the mains socket.
Never use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since these
could damage the housing or even impair operation.
Use a dry, lint-free cloth to clean the product.
Disposal
Electronic devices are recyclable material and do not belong in the household
waste. Dispose of an unserviceable product in accordance with the relevant statu-
tory regulations.
Technical Data
Operating voltage ......................... 230 V/AC, 50 Hz
Connection power ......................... Ohmic load: max. 3680 W (230 V/AC, 16 A)
...................................................... Inductive load: max. 460 W (230 V/AC, 2 A)
Devices with mainly resistive load are, e.g., light bulbs, heaters, etc.
Powered devices with inductive load are, e.g., engines, control gears, conventional
transformers, energy-saving bulbs, etc.
Switch type ................................... Relay (single-pole)
Temperature adjustment range ..... Heat mode: +5 °C to +30 °C
...................................................... Cooling mode: +10 °C to +35 °C
Accuracy ....................................... ±/0.5 °C
Backup rechargeable battery ........ yes, built-in permanently (NiMH, 2,4 V); charging time
ca. 14 h, back-up time ca. 30 days
Socket with child protection .......... yes
Ambient conditions ....................... Temperature 0 °C to +40 °C, air humidity 0% to 90% rela-
tive, not condensing
Dimension ..................................... 129 x 55 x 78 mm (H x W x D, including plug)
Weight .......................................... 170 g
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sygonix MH-912 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sygonix MH-912 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 0,44 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info