1� About This Document
Please read carefully and keep in a safe place�
Under copyright. Reproduction either in whole or
in part only with our consent.
Subject to change in the interest of technical
progress.
Symbols
!
Hazard warning!
...
Reference to other information in the
document�
2� General Safety Notification
• Disconnect the power supply before attempting
any work on the unit.
• During installation, the electric power cable to be
connected must not be live. Therefore, switch off
the power first and use a voltage tester to make
sure the wiring is off-circuit.
• Installing the sensor-switched light involves work
on the mains supply voltage.
This work must therefore be carried out pro-
fessionally in accordance with national wiring
regulations and electrical operating conditions.
(
D
- VDE 0100,
A
- ÖVE / ÖNORM E8001-1,
h
- SEV 1000)
• Only use genuine replacement parts.
• Repairs may only be made by specialist work-
shops.
3� RS PRO LED Q1
The sensor-switched indoor light is an efficient light
that controls itself. A high-frequency sensor for
detecting persons, a light sensor for identifying the
room's lighting situation as well as LEDs requiring no
maintenance provide efficient, instantaneous light.
Several lights in one room can be networked into a
group via the 868MHz wireless communication unit
(channel selection). Wireless communication to the
next light functions reliably over a distance of 50 m.
All lights then operate with equal rights and act as
one overall light.
Optionally, all function settings can be made via the
RC10 remote control ( "8� Accessories")
!
The sensor-switched light is an active motion
detector. The integrated HF sensor emits high-
frequency electromagnetic waves (5.8GHz) and
receives their echo. The change in echo caused by
the slightest movement within the detection zone of
the light is detected by the sensor. A microproces-
sor then issues the switch command "switch light
ON". Detection is possible through doors, panes of
glass or thin walls.
Detection zones:
1) Minimum reach (Ø 1 m)
2) Maximum reach (Ø 8 m)
Note:
The high-frequency power of the HF sensor is
approximately 1mW – 1000 times less than the
transmission power of a mobile phone or micro-
wave oven.
Package contents (Fig� 3�1)
Product dimensions (Fig� 3�2)
Device overview (Fig� 3�3)
A Ceiling mount
B DIP switches
Channel selection
Dimming function
C Twilight setting
D Time setting
E Reach setting
F Plug connection
G Light enclosure
H Retaining screws
4� Installation
• Switch OFF power supply (Fig� 4�1)
Connect the mains power supply lead (Fig� 4�2)
The mains power supply lead is a 3-core cable:
L = phase conductor
(usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors using
a voltage tester; then disconnect from the power
supply again. Connect phase (L) and neutral con-
ductor (N) to the terminal block.
Important:
Incorrectly wired connections will produce a short
circuit later on in the product or your fuse box. In
this case, you must identify the individual conduc-
tors once again and re-connect them. A mains
power switch for turning the unit ON and OFF may
of course be installed in the mains supply lead.
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged
Mounting procedure
• Select appropriate mounting location, taking the
reach and motion detection into consideration
• Switch OFF power supply (Fig� 4�1)
• Mark drill holes (Fig� 5�2)
Drill holes and insert screw anchors (Fig� 5�3)
Directly via the connection socket (Fig� 5�3)
With spacers for surface-mounted cables
(Fig� 5�4)
• Connect conductors (Fig� 4�2)
• Switch ON power supply (Fig� 5�5)
• Make potentiometer settings (Fig. 5�6)
"6. Functions"
• Set DIP switches (Fig� 5�7)
"6� Functions"
• Fit light enclosure (G) onto ceiling mount (A) and
clip into place. Pay attention to plug connection
(F) (Fig� 5�8).
• Screw in retaining screws (H)
approx� 1mW approx� 1000mW
6� Function
After the ceiling mount has been installed and the
mains connection has been made, the sen-
sor-switched light is ready for use. When putting
the light into operation manually at the light switch,
it will switch OFF after 10seconds for the calibra-
tion phase and is then activated for sensor mode.
It is not necessary to operate the light switch a
second time.
Potentiometer function (Fig� 5�6)
Reach setting (sensitivity) (E)
Factory setting: 8m
Reach is the term used to describe the diameter of
the more or less circular detection zone produced
on the ground after mounting the sensor-switched
light at a height of 2.5m.
Potentiometer set to maximum = max. reach
(approx. Ø 8 m)
Potentiometer set to minimum = min. reach
(approx. Ø1m)
Potentiometersetto"•"= sensor OFF
Motion detection and all other sensor functions are
completely deactivated. In this setting, the light can
be used as a normal light and turned ON and OFF
at the light switch (DIP 1-5 = OFF).
Limiting reach
By fitting the shrouds supplied with the light, the
reaches can be reduced in four directions
(Fig� 6�1 to 6�4).
Time setting (stay-ON time) (D)
Factory setting: 5 seconds
The light's ON time can be set to any period from
approx. 5seconds to a maximum of 15minutes.
Any movement detected before this time elapses
will restart the timer.
Note: After the light switches OFF, motion detection
is interrupted for approximately 1second. The light
will only switch ON in response to movement once
this period has elapsed.
Twilight setting (response threshold) (C)
Factory setting: 2000 lux
The light's chosen response threshold can be infinite-
ly varied from approximately 2 to 2000 lux.
Control dial set to = daylight operating mode
(depending on ambient light level)
Control dial set to = night-time operation
(approx. 2lux)
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Steinel RS PRO LED Q1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Steinel RS PRO LED Q1 in de taal/talen: Alle talen als bijlage per email.

De handleiding is 1,76 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info