593103
5
Verklein
Vergroot
Pagina terug
1/54
Pagina verder
Once you have installed the wall mount, connected the
SensorLight to the power supply and fitted the sensor
lens, you are ready to put the SensorLight into oper-
ation. Programming buttons can be used for selecting
any of three settings. Pressing any of the program-
ming buttons will set the lamp to programming mode.
This means:
- The lamp will always switch OFF.
- The sensor function will be deactivated.
- Manual override function (if activated) will
be interrupted.
The settings may be altered as often as you wish.
The last setting will remain stored in the memory in
the event of power failure.
Twilight setting
(response threshold)
(factory setting: daylight operation 2000 lux)
The chosen light threshold can be adjusted continu-
ously from about 2 lux to 2000 lux.
a) Selecting twilight setting of your choice:
At the light level at which you want the light to
respond to movement, press the button until the red
LED flashes. This light level will now be stored.
b)
Setting night-time operation (4 lux) during the day
Hold button down for approx. 5 seconds until red
LED stops flashing in the lens.
Switch-off delay
(time setting)
(factory setting: approx. 10 sec.)
The 'ON' time can be varied continuously between
approx. 5 sec. and a maximum of 15 min.
Setting light 'ON' time of your choice:
- Hold button down until red LED flashes.
- Release button and wait until chosen 'ON' time
is shown (LED flashes).
- Now press button a second time until LED goes
out. The chosen time is now stored to the exact
second.
- This process is terminated automatically after the
maximum setting time (15 minutes).
- To select the shortest time setting, press the button
twice in brief succession.
Basic lighting level
(factory setting: dimmer OFF: 0%)
Basic lighting level can be infinitely varied from 0 to
50 %. This means: Light is only switched to max-
imum output when movement is identified in the
sensor's detection zone. Note: Depending on the
local power grid, the LED's may flicker slightly
when dimmed. This is not a product defect and no
reason for complaint.
Installation / Wall mounting
The site of installation should be at least 50 cm
away from another light because heat radiated from
it may activate the system. To obtain the specified
reach of 5/12 m, the sensor should be installed at a
height of approx. 2 m.
Installation procedure:
1. Hold wall mount against the wall and mark drill
holes.
2. Drill holes, insert wall plugs (6 mm dia.).
3. Feed power supply lead through. For surface
wiring, break open pre-punched cable entry, insert
sealing plug, pierce and feed through power supply
lead.
4. Screw-fasten wall mount to the wall.
5. Connecting the mains supply lead (see Fig.
)
The main supply lead is a 2 to 3-core cable:
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective earth conductor (green/yellow)
If you are in any doubt, identify the conductors using
a voltage tester; now switch the current off again.
Connect the phase conductor (L) and neutral con-
ductor (N) to the clamp-type terminal. The protective
earth conductor may be sealed off with insulation
tape.
Note: A mains switch for switching the unit ON and
OFF may of course be installed in the power supply
lead.
A mains switch is required for the manual override
function (see Manual override function
).
6. Fit sensor lens (reach either 5 m max. or 12 m),
see Reach setting. Fit clip-on shrouds if
necessary.
7. Fit decorative sensor cap onto wall mount and
clip into place.
8. Fit decorative trim panel and screw in place.
9. Fit glass shade
and secure in place with eccen-
tric screw
.
10. Select basic light level
, time
and twilight
settings (see ‘Functions’).
11. Fit button cover .
Functions
- 9 -
Installation instructions
Dear Customer,
Congratulations on purchasing your new STEINEL
SensorLight and thank you for the confidence you
have shown in us. You have chosen a high-quality
product that has been manufactured, tested and
packed with the greatest care.
Please familiarise yourself with these instructions
before attempting to install the SensorLight because
prolonged reliable and trouble-free operation will only
be ensured if it is fitted properly.
We hope your new STEINEL SensorLight will bring
you lasting pleasure.
Technical specifications
GB
Safety warnings
Disconnect the power supply before attempting
any work on the unit.
The electrical connection lead must be dead during
installation. Therefore, switch off the power first and
use a voltage tester to make sure the wiring is off
circuit.
Installing the SensorLight involves work on the
mains voltage supply. This work must therefore
be carried out professionally in accordance with
applicable wiring regulations and electrical
operating conditions.
(
-VDE 0100,
A
-ÖVE/ÖNORM E 8001-1,
-SEV 1000)
Only perform function settings
, ,
with the
lens fitted.
System components
Wall mount
Eccentric fitting for securing the glass shade
Sensor lens (removes and turns for selecting the
max. basic reach setting of 5 m or 12 m)
Twilight setting
Time setting
Basic lighting level / Watt-o-matic (dimming)
Mains power connection
Decorative sensor cap
Decorative trim panel
Glass shade
LED, red
Mains connection, concealed wiring
Mains connection, surface wiring
Button cover (prevents unintentional adjustment)
Principle
The integrated infrared sensor is equipped with two
120° pyro sensors that detect the invisible heat
emitted by moving objects (people, animals etc.).
The heat detected is converted electronically into a
signal that switches the light ON automatically. Heat
is not detected through obstacles, such as walls or
panes of glass. Heat radiation of this type will, there-
fore, not trigger the sensor. The two pyro sensors
provide an angle of coverage of 180° with an angle of
aperture of 90°. The sensor lens removes and turns.
This allows you to select two basic reach settings of
5 or 12 metres max.
Important: The most reliable way of detecting move-
ment is to install the unit with the SensorLight aimed
across the direction in which a person would walk and
by ensuring that no obstacles (such as trees, walls
etc.) obstruct the line of sensor vision.
- 8 -
Dimensions (H x W x D): 330 x 208 x 107 mm
Mains voltage: 230 – 240 V, 50 Hz
Output: 8 W LED / 160 lm
Colour temperature: 3200 kelvin (warm white)
LED life expectancy: 50.000 hours
Angle of coverage: 180° with 90° angle of aperture
Detection reach: 12 or 5 m (2 basic settings)
Twilight setting: 2 – 2000 lux
Time setting: 5 sec. – 15 min.
Basic lighting level: 0 – 50%, soft light start
Manual override: 4 h, switchable
IP rating: IP 44
Protection class: II
Temperature range: -20 °C to 50 °C
GB
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Steinel L 610 LED bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Steinel L 610 LED in de taal/talen: Alle talen als bijlage per email.

De handleiding is 1,14 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info