18
9. Compact pellet use
The pellet stove must be serviced as described in point 3.6, page 99
(Warranty). In order to adjust the operating parameters of the stove (pellet
appliances), the dosing must be adjusted as described in section 8 of this manual.
The pellet dose must be adjusted according to the gas temperature and pellet
consumption of the appliance at the rated power described in Table 1, page 6, to
ensure that the appliance delivers the correct power.
Recommendations
Before you start the appliance you must check the following points:
• Ensure that the compact is correctly connected to the mains via the 230VAC
supply cable.
Figure 12 - Power connection plug
• Check that the pellet tank is filled. There is a safety grille inside the pellet tank
to prevent the user from accessing the worm screw.
• Ensure that before each ignition the burner is unobstructed.
The compact's combustion chamber and door are constructed of iron
plate painted with high temperature paint, releasing fumes in the first few
firings due to the curing of the paint. If this occurs, open the windows and
doors leading to the outside to ventilate the room. Avoid touching the door
of the equipment during the first firing, so as not to leave permanent
marks on the paint. The paint dries at approximately 300ºC for 30 minutes.
Make sure the hydraulic circuit is correctly mounted and connected to water.