General description
The is an accurate hand-held datalogger that displays & records relative
humidity, temperature, CO2 and calculated parameters such as dew point and wet bulb.
These short instructions are limited to a description of the main functions and installa-
tion of the device. The detailed instruction manual can be found on the Internet at
www.senseair.se
Programming
Most of the settings, such as memory clear, CO2 alarm, units( C/ F), sampling rate,
pressure compensation and real time clock can be changed using the function keys.
Built-in CO2
sensor w/
calibration cap
Battery
compartment
Integrated probe
Tripod hole
Congratulations on your purchase of the new portable humidity, temperature and CO2
instrument. Please read these short instructions carefully before installing the device.
Press to turn the meter on. At power up,
it emits a short beep and performs a 28 sec.
countdown (Fig.1) for meter warm up, then
enters normal mode with real time clock
displayed (Fig.2). Date and time are
displayed in turns.
POWER ON/OFF
SET
ON/ OF F
CO2
AM
Fig.2
To power off, press again to turn off the
meter.
Operation
Fig.1
SET
ON/ OFF
Power Supply
The uses four AA re-chargable batteries as power source. To insert
(replace) the batteries, use the screwdriver enclosed to loose two screws and put in
the batteries in correct polarity with good contact.
Connection to PC or Laptop
Connect the via mini USB cable to a PC or Laptop. Recorded data can be
easily downloaded with the software enclosed.
Please charge the batteries for eight hours on first time use. To charge the
batteries, power off the meter and plug in the 9VDC adaptor enclosed. Wait until
"End" appears on LCD to indicate the charging process is completed
(approximately four hours).
TAKING MEASUREMENT
The meter starts measurement when power on and update readings every second.
In the condition of operating environment change, it takes 30 seconds to respond
for C sensor. O2
NOTE: Do not hold the meter close to faces in case exhalation affects CO2
%rh
TEMP
O
C
AM
Press to switch to temperatures display (Fig.4,5,6).
The lower display shows the real time clock.
TEMP, DP, WBT
Press to switch the mode to CO2. User can get the
CO reading in ppm unit on main display (Fig.7). The 2
lower display shows the real time clock.
CO2 (CARBON DIOXIDE)
Fig.7
Fig.5
Fig.6
Press to switch to humidity display (Fig.3).The
lower display shows the real time clock.
HUMIDITY
Fig.3
CO2
AM
Fig.4
O
C
AM
DP
O
C
AM
WBT
MODE
RECALL
DATA HOLD
In normal display mode, press to freeze the
readings, "HOLD” icon is flashed on the left top of LCD
(Fig.8). All current readings are kept unchanged.
Press again to cancel the hold function.
Fig.8
DISPLAY BACKLIGHT
HOLD
NOTE:
The hold function is disabled in MIN/MAX/AVG mode.
START
ESC
Fig.9
Fig.10
Fig.11
Fig.12
%rh
HOLD
CO2
AM
CO2
MAX
CO2
AVG
HOLD
The backlight will be activated for 10 seconds by
pressing any key.
MIN/MAX/AVG REVIEW
This meter allows you to check the minimun, maximum,
average and the current value from the moment you
press the key. Under normal mode, each press of
displays the MIN, the MAX, the AVG and the current
value in sequence (Fig.9~11). To return to normal mode,
press to escape(Fig.12)
In the MIN/MAX/AVG mode, it shows the corresponding
readings on main display and the accumulated time of
this mode. The maximum time interval for this function
is 18h.
Press to switch the displayed parameters (Fig.13).
Distinguish the normal display and current review by
checking the time display format. In normal display, date
& time are displayed in turns. In current review, the lower
display is the accumulated time of how long you have
been in MIN/MAX/AVG mode.
MAX/AVG
MIN
NOTE:
HOLD” & “MANUALLY RECORD” & “RECALL” functions are disabled in
MIN/MAX/AVG mode.
%rh
MAX
CO2
ALARM
The meter features audible alarm to give warnings when CO2 concentration exceeds
the limit. (See “Meter Setup” section for setting alarm threshold). It emits beeps
(about 80dB) when CO2 level goes over the set value and stops only when the
readings fall below the set value. It beeps again when value goes over the limit.
Fig.13
MODE
RECALL
MODE
RECALL
MODE
RECALL
DATE/TIME SETUP
When meter is powered on , hold down for more than two seconds until entering
meter setup mode. Press or key to select the program P80 (rtc) and press
key to enter.
First, choose the time format as 12hour or 24hour by pressing or and then
press to confirm. Second, choose the date format as Month-Day-Year or Day-
Month-Year by pressing or and then, press key to confirm. Now, start to
input the real time clock value from year, month, day, hour, minute to second. Press
or to select and then press to confirm. Press to return to normal.
SET
ON/ OFF
HOLD
MEM
MAX /AVG
MIN
START
ESC
HOLD
MEM
HOLD
MEM
MAX /AVG
MIN
HOLD
MEM
MAX /AVG
MIN
MAX /AVG
MIN
UNIT SETUP
When meter is powered on , hold down for more than two seconds until entering
meter setup mode. Press or key to select the program P50 (unit) and press
key to enter.
Press or to select or and then press to confirm. Press to return
to normal.
SET
ON/ OFF
MAX /AVG
MIN
START
ESC
HOLD
MEM
MAX /AVG
MIN
HOLD
MEM
o
C
o
F
MAX/AVG
MIN
Functions Key
ON/OFF/SETUP
-Press to turn on or turn off the instrument
-In normal mode, press longer to enter setup mode.
-Press with HOLD key to disable sleep mode
HOLD/UP
-Freezes the current readings
-Cancels data hold function
-Selects unit or increases value in setup
MODE/RECALL
-Press to switch displayed parameter
-Press longer to enter memory recall
START/ESC
-Start automatic logging mode
-Exits setup/recall/logging
MEM/DOWN
-Press to manually record the reading
-Selects unit or decreases value in setup
MIN/MAX/AVG/ENTER
-Activates MIN,MAX,AVG function
-Saves and finishes settings
Display
Upper LCD
Lower LCD
CO2
HOLD
MIN/MAX
AVG
DP
TEMP
WBT
%rh
o o
C/ F
CAL
REC
RECALL
CO2
%rh
TEMP
DP
WBT
O
F
O
C
REC
Recall
AM
MAX
MIN
HOLD
AVG
CAL
PM
Humidity/TEMP/CO2....reading
Real time clock display
Carbon dioxide reading
Readings are hold unchanged
Minimum/Maximum readings
Average reading
Low battery indicator
Dew point temperature
Temperature
Wet bulb temperature
Unit of relative humidity
Celsius/Fahrenheit temperature
In calibration status
In manual/automatic logging status
In manual records recall mode
PC connect port
9VDC adaptor port
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Senseair pSENSE II bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Senseair pSENSE II in de taal/talen: Engels als bijlage per email.

De handleiding is 1,04 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Senseair pSENSE II

Senseair pSENSE II Gebruiksaanwijzing - Nederlands - 5 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info