Under temperature alert setting mode, click Alert key to confirm the setting items, the sequence: channelsetting the Maxsetting the
Min.
▲Key
Under standard mode, click to choose the unit of air pressure: Hpa/Mb or inHg.
Under setting mode, click once to go forward one step/second, hold for 2 seconds to go forward 8 steps/second.
▼Key
Under standard mode, click to choose the unit of temperature between °C/°F.
Under setting mode, click to go backward one step, hold for 2 seconds to go backward 8 steps/second.
HISTORY Key
Under standard mode, clicking to check the air pressure record of past 12 hours.
RF Receiving Mode
1. After power-on and finishing testing temperature, humidity and air pressure, it enters RCC receiving state for 3 minutes. Under
standard mode, hold CH key for 3 seconds to enter RF receiving mode. If there is no new effective signal from sensors in 60 minutes,
the outdoor temperature of that CH will display ----”.
2. The outdoor temperature will display valid value of that CH from ---- when the main unit detects and receives the correct signal
from that CH again.
3. Hold “CHANNEL”, it displays CH1-->CH2-->CH3-->auto recycling (5 seconds a shift).
TIME MODE
1. The default time after power-on is 2007.1.1, 0:00:00, the range of perpetual calendar 2000-2099.
2. Under standard mode, hold TIME SET key for 2 seconds to enter time setting mode.
3. Under setting mode, press UP or DOWN key to adjust the data of items to be set, click TIME SET to confirm the data.
4. Under setting mode, the items being set will flash in the frequency of 2Hz/second, the setting sequence: year monthdate
language12/24HRhour minutetime zoneexit.
5. If there is no valid operation on the key after 7 seconds, it will exist the setting mode, but the items set will be kept. The valid keys
include TIME SET, UP, DOWN.
ALARM ALERT MODE
1. Under standard mode, click ALARM to view the Alarm time, the sequence: AL1, AL2, Normal.
2. Under standard mode, click UP key to switch the alarm ON/OFF, the sequence: AL1 ON, AL2 OFFAL1 OFF, AL2 ONAL1
ON, AL2 ONAL1 OFF, AL2 OFF.
3. Under ALARM time displaying mode, hold ALARM key for 2 seconds to enter ALARM setting mode.The setting sequence:
AL1/AL2hour settingminute settingexist setting mode.
4. During the setting, click UP or DOWN key to adjust the items to be set, and click ALARM key to confirm the items.
5. If there is no effective operation on the key after 8 seconds, it will exit the setting mode, but the items set will be kept. The effective
keys include ALARM, UP, DOWN.
6. Alarm ringing for 2 minutes totally ,and Alarming format::
(1) 0~10 seconds: one Beep/second;
(2) 10~20 seconds: two Beeps/second;
(3) 20~30 seconds, three Beeps/second;
(4) After 30 seconds, Beeping continuously.
The alarm is switched on after set.
CITY SETTING
1. Under standard mode, hold LOCATION key for 2 seconds to enter location setting and choose the city you stay (there are 160
European cities for selection).
2. Click UP or DOWN to choose, and click LOCATION key to confirm.
SUNRISE / SUNSET , MOON PHASE AND TIDE
1. The unit will calculate automatically the time of sunrise/sunset of the city everyday after the city is selected.
2. It will calculate moon phase and tide ebb/ flux every day according to the calendar. There are 8 states of moon phase and 3
step(H,M,L) of tide in all
THERMOMETER AND HYGROMETER
1. The indoor temperature range: C-50°C (32°F-122°F), and the outdoor temperature range: -50°C-70°C (-58°F-158°F).
2. Humidity range: 20%-95%.
AIR PRESSURE AND WEATHER REPORT MODE
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Saxon 8710P3 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Saxon 8710P3 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,21 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info