Safety regulations and measures
1. The electrical installation must be switched off during installation.
2. Install the power-inlet according to the stated instructions and directions in the
manual.
3. Use cables with appropriate wire size. See table “WIRE SIZE”.
4. Connections and safety features must be executed according to the locally
applicable regulations.
Things you need for installation
Pencil
Electric drill
Hole saw
Drill bit
Small flat blade screwdriver
2.5mm hexagonal socket wrench for the 4mm SS screws
Cutting / wire stripping pliers
Installation direction
To install the power-inlet, proceed as follows:
1. Make a cut out in ship’s hull using the outline drawings of figure 1.
2. Remove the rear safety enclosure from the inlet.
3. Pull internal wiring through the hull opening.
4. Thread the wiring through the strain relief on the rear safety enclosure. Slide the
mounting gasket over the wiring.
5. Back off terminal screws on the rear housing of the inlet.
6. Dismantle cable 50 mm, cut back green/yellow wire for 20 mm, strip wire ends 6
mm. Make sure the wire strands are clean and not corroded. If necessary, cut back
the wire until clean wire is uncovered. Do not solder the ends of the wire!
7. Insert wires into the proper colour coded terminal openings (see table
“specifications” for the proper colour codes) on the back of the inlet. Tighten
terminal screws to 1.6-2.2Nm (14-20 in.-lbs.) torque. Make certain there is no wire
insulation under any terminal.
8. Slide the rear safety enclosure onto the back of the inlet.
9. Position the gasket and inlet over the hull opening, align the mounting holes and
attach the inlet to the hull with screws. Install the inlet with the M4 screws
included.
SPECIFICATIONS
General
MP50-10
Ø Connections:
2p + E
Ø Voltage:
230 V
Ø Maximum current (Amps):
50A / 230V
Ø Protection degree:
IP 56 (IEC529)
Ø Marking:
CE
Materials
Ø Cap and bezel
316 Stainless steel
Ø Contact blades / terminal parts:
Nickel plated brass
Ø Plug body:
PA6, V0 quality
COLOUR CODES
Function:
Wire colour:
Terminal colour code:
PE (ground)
Yellow / green
Green
N (neutral)
Blue
Blue
L1 (phase, load)
Brown or black
Brown
WIRE SIZE
Voltage (Volts)
Current (Amps)
Cross section
American Wire Gauge
230 V AC
50 A
10 mm²
AWG 7
\NGLISH
Veiligheidsvoorschriften en maatregelen
1. Gedurende de installatiewerkzaamheden moet de elektrische installatie
spanningsloos zijn.
2. Monteer de landaansluiting volgens de voorschriften en aanwijzingen in dit
montagevoorschrift.
3. Gebruik kabels met voldoende aderdoorsnede: zie tabel “WIRE SIZE”.
4. Aansluitingen en beveiligingen moeten in overeenstemming met de plaatselijk
geldende voorschriften worden uitgevoerd.
Dit heeft u nodig voor de installatie
Potlood
Boormachine
Gatenzaag
Boortje
Kleine platte schroevendraaier
2.5mm inbussleutel voor de meegeleverde M4 RVS schroeven
Kniptang en striptang
Installatievoorschrift
Ga bij de installatie van de contactdoos als volgt te werk:
1. Maak aan de hand van de inbouwmaten in afbeelding 1 een uitsparing in de
scheepswand.
2. Verwijder de isolatiekap aan de achterzijde van de contactdoos.
3. Trek de bedrading door de isolatiekap.
4. Voer de bedrading door de trekontlasting van de isolatiekap. Plaats de rubberen
montage pakking over de bedrading.
5. Draai de schroeven van de aansluitklemmen aan de achterzijde van de contactdoos
een paar slagen los.
6. Ontmantel de isolatie van de kabel over 50mm, en knip de geel/groene ader 20mm
terug. Strip de draadeinde 6mm. Let er op dat de aders blank zijn en niet
gecorrodeerd. Zonodig de bedrading inkorten en de kabel opnieuw strippen. De
aders mogen niet vertind worden!
7. Sluit de aders op de juiste aansluitklemmen aan de achterzijde van de contactdoos
aan (zie tabel “specifications” voor de juiste kleurcodes). Draai de schroeven van
aansluitklemmen goed aan. (1.6-2.2Nm). Let er op dat er geen isolatie onder de
aansluitklemmen zit.
8. Monteer de isolatiekap aan de achterzijde van de contactdoos.
9. Plaats de rubber pakking tezamen met de contactdoos zodanig in de uitsparing in de
scheepswand dat de montagegaten op de juiste plaats zitten. Bevestig de
contactdoos op de scheepswand met behulp van de meegeleverde vier M4-
schroeven.ENGL
ENGLISH
SPECIFICATIONS
WARNING:
THIS INLET IS INTENDED FOR BOATS WIRED FOR THE EUROPEAN MARKET.
RATING: 50A/230VAC (50Hz)
.........................................................................................................................................................................................................................................................................................................................................................................
THE REQUIREMENTS FOR INSTALLATION OF ELECTRICAL SYSTEMS ON CRAFT OF HULL
LENGTH UP TO 24M ARE SPECIFIED IN THE ISO 13297 STANDARD.
Ratio Electric B.V. Ambachtsstraat 12, NL-3861 RH Nijkerk, The Netherlands. Tel.: +31-33-2452360 Email: info@ratio.nl
Web:
www.ratio.nl Version MP010 1/2017
!
MP50-10!
A
74 mm
B
5,5 mm
C
60 mm
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Ratio MP50-10 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Ratio MP50-10 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 0.47 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info