599858
1
Verklein
Vergroot
Pagina terug
1/5
Pagina verder
Before the measurement, please make sure the selected
button accords with the measured position.
TH52Z Multi-function Infrared Thermometer
Functions
Real Time Clock
The real time clock will be recorded with the memory function and help you to recognize each
measurement result. (It includes the 12/24 Format_Hour_Minutes_Date.)
Please see the “Real time clock setting” section to learn how to setup the time in the first use.
Room Temperature
Suitable ambient temperature is important for the baby and patient, the thermometer always help you
recognize the room temperature.
Setting “Real time clock” first to enable this function. After power off, room temperature will be shown
on the screen with
icon.
Please see the “Use of the thermometer” section to learn how to get the correct room temperature.
Forehead / Ear
Temperature
The thermometer has been designed for practical use. It’s not meant to replace a visit to the doctor.
Please also remember to compare the measurement result to your regular body temperature. Please
consult with doctor if you have health concerns.
Please see the “Use of the thermometer” section to learn how to measure the body temperature.
Scan Mode
The Scan mode shows the actual, unadjusted surface temperatures, which is different from the body
temperature. It can help you to monitor if the object temperature is suitable for the baby or patient, for
example the baby’s milk.
Please see the “Use of the thermometer” section to learn how to measure the object temperature.
Stopwatch
The thermometer built the stopwatch function to help you to monitor the heartbeat
since heartbeat is one
of the healthy indexes for people.
Please see the “Use of the Stopwatch” section to learn how to measure the heartbeat result.
Fever Alarm
If thermometer detects a body temperature > 37.5°C, there will be a long beep sound followed by three
short beep sound to warn the user for potential fever.
Zone Indicator
Under ear or forehead mode, if thermometer detects a body temperature< 37.5°C, there will be " Green"
light signal; if temperature > = 37.5°C and < 38.0°C, there will be" Yellow" light signal; if temperature
> =38.0°C, there will be" Red" light signal.
Memory Locations
There are total 9 sets memories for body measurement. Each memory also records the measurement
date/time/mode icon and site location..
When in power on, Press the “ON/MEM” button to see the temperature stored with
icon.
°C / °F Switch
In “power off” mode (The LCD only shows the date, time and room temperature). Press and hold the
“FOREHEAD” button, then immediately press and release the “ON/MEM”
button. After 3 seconds, icon
“°C” will be switched to icon “°F”. (You may use the same way to switch back to “°C”)
Real time clock setting
1. Power on: Press the “ON/MEM” button. The thermometer is ready for use after hearing two beep sounds.
2. Press and hold the “ON/MEM” button for 5sec. When you see the Set icon starts flashing, it indicates that you are in the setting screen.(see the following figure.)
3. Press the “FOREHEAD” button to make the “24” icon flash. This indicates that you are in the 12/24-hour setting screen. Press the “FOREHEAD” button to set
12/24-hour Format from “24”(24-hour) to “12”(12-hour).
4. Press “ON/MEM” button to move the flashing in the sequence shown below to select our settings:
hourminutesyearmonthdayleave the setting screen.
5. While the hour, minutes, year, month, day setting is flashing, use “FOREHEAD” button to change it.
Use of the thermometer
1. Always make sure the probe is clean, and without damage.
2. Power on: Press “ON/MEM” button.(see figure 1)
3. Mode selection:
3.1 Ear mode :Press the “Ear” button, you can get the body temperature by ear measurement after
hearing two beep sounds. (see figure 1)
Specifications
Temperature measurement range:
Forehead / Ear mode: 34~42.2°C (93.2~108°F), Scan mode: -22~80°C (-7.6~176°F)
Operating temperature range: 10~40°C (50~104°F)
Storage temperature range: It should be stored at room temperature between -20~+50°C,
RH85%
Transportation temperature shall be less than 70°C, RH95%
Comply with ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part
5:Performance of infra-red ear thermometers(with maximum device),
IEC/EN60601-1-2(EMC),IEC/EN60601-1(Safety) standards.
Accuracy:
For ear mode: +/-0.2°C (0.4°F) during 35.5~42°C (95.9~107.6°F),
+/-0.3°C (0.5°F) for other range.
For forehead mode: +/-0.2°C (0.4°F) during 36~39°C (96.8~102°F),
+/-0.3°C (0.5°F) for other range.
For scan mode: +/-0.3°C (0.5°F) during 22~42.2°C (71.6~108°F),
others +/-4% or +/-2°C (4°F) whichever is greater.
Fever alarm & Memory locations under “Ear/Forehead mode” (with each measurement
date/time/mode icon)
3 color LED Fever Indicator
Real time clock, °C / °F Switch mode
Battery: one lithium cell battery (CR2032 *1pcs)
This thermometer converts the ear/forehead temperature to display its “oral equivalent.”
There is no gender and age limitation for using infrared thermometer.
This is not an AP or APG product.
Figure 1 Figure2 Figure 3 Figure
4
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Radiant TH52Z bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Radiant TH52Z in de taal/talen: Engels als bijlage per email.

De handleiding is 0,23 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info