POWP3060 EN
Copyright © 2018 VARO P a g e | 7 www.varo.com
8.3 Additional handle (Fig. 4)
For safety reasons you must only use the demolition hammer with the
additional handle.
▪ The additional handle (1) enables you to achieve better stability while using the demolition
hammer.
▪ The additional handle can be turned into any required position. To do so, undo the lock
knob (8) of auxiliary handle. Then turn the handle into the most comfortable working
position and tighten the lock knob (8) again.
Important! To avoid danger, the machine must only be held using the two
handles (2-3). Otherwise you may suffer an electric shock if you chisel
into cables.
9 LUBRICATION - OIL LEVEL
Check the oil level before using the machine.
▪ Place the machine on the floor with the tool chuck (5), pointing downwards.
▪ The oil must be at least 3 mm above the bottom of the inspection window (6).
The oil should be changed after around 40-50 hours of use.
Recommended oil: 25ml SAE 15W/40 or an alternative of the same quality.
9.1 Oil change (Fig. 5)
▪ Switch off the machine and disconnect the plug from the socket.
▪ Undo the 4 screws of the inspection window (6) using a screwdriver and drain the oil.
▪ To prevent the oil from running out in an uncontrolled manner, hold a small metal chute
under the opening and collect the oil in a vessel until it has fully drained out of the
machine.
Important: The waste oil must be disposed of in the appropriate collection
point for waste oil.
▪ Add new oil (approx. 25 ml) through the oil filler opening until the oil level reaches the
required level. Tighten the hexagonal screw again.
▪ Re-check the oil level after a short period of operation.
10 MAINTENANCE
Check every day the tightening of screws and nuts. Except the procedures described in this
manual, this tool needs no specific maintenance. The repair of the tool's inner components is
of the competence of specialists. The cleaning of plastic parts is done with a soft damp cloth
and a bit of mild soap. Never submerge the tool and do not use detergents, alcohol, spirit,
etc... For an in-depth cleaning, please consult the after-sales department.
WARNING: For maintenance and cleaning, always remove the plug from
the electric power supply. Never use water or other liquids to clean
electric parts.