737067
1
Verklein
Vergroot
Pagina terug
1/8
Pagina verder
Ph Sf Cpny r eac n s gurte
1. OPENING THE LOCK
1.1. Press«ON» – single acoustic signal and green LED;
1.2. Enter master or user code, consisting of 6...8 symbols (master code
set up in the factory, 1-2-3-4-5-6, the user code is not activated);
1.3. Press«ENTER». After the green LED is activated the lock is ready to
open during 5 seconds.
2. PROGRAMMING
2.1 Master-code programming:
Press «ON»;
Press «ENTER»;
Press «1»;
Press «ENTER»;
Enter valid master-code and press «ENTER»;
Enter new master-code (6 symbols minimum, 8 symbols maximum)
and press«ENTER»;
Enter new master-code again and press «ENTER».
A correct input of the valid or new master-code followed by a double
acoustic signal and green LED. An incorrect input of the actual or new
master-code followed by a single long beep and red L.E.D..
2.2 User-code programming (using master-code)
Press «ON»;
Press «ENTER»;
Press «2»;
Press «ENTER»;
Enter valid master-code and press«ENTER»;
Enter user-code (6 digits minimum and 8 digits maximum) and
press«ENTER»;
Enter user-code again and press «ENTER».
2.3 User-code programming (without using master-code)
Press «ON»;
Press «ENTER»;
Press «3»;
Press «ENTER»;
Enter valid user-code and press«ENTER»;
Enter new user-code (6 minimum, 8 maximum) and press «ENTER»;
Enter new user code again and press «ENTER».
2.4 Deleting the user-code
Press «ON»;
Press «ENTER»;
Press «0»;
Press «ENTER»;
Enter valid master-code and press«ENTER»;
The user code is deleted, only the master-code is valid.
2.5 Dual code programming (master code and user code must al-
ready be programmed to enable this function)
Press «ON»;
Press «ENTER»;
Press «7»;
Press «ENTER» (If only master code is active, there will be a short
acoustic signal and red LED will be turn on. The lock will then turn o,
and the red LED will no longer be visible).
Enter valid master code and press «ENTER»;
2.6 Opening the lock using dual code function:
Press «ON»;
Enter valid master code;
Press «ENTER»;
2.6.1 There will be a short acoustic signal accompanied by green LED.
2.6.2 During the next 60 seconds with intervals of 5 seconds there will be
short acoustic signals accompanied by green LED. During this time a valid
user code must be entered, followed by «ENTER».
2.6.3 If the user code is entered correctly, the lock will open, accompanied
by a short acoustic signal and green LED.
2.6.4 If the user code is not entered or is entered incorrectly during the
60 seconds, there will be a long acoustic signal accompanied by red
LED. The lock then powers down and the opening procedure has to be
repeated from the beginning.
2.6.5 If the master code is entered incorrectly, there will be a long acoustic
signal accompanied by red LED. The lock then powers down.
2.7 Turning o Dual Code:
Press «ON»;
Press «ENTER»;
Press «8»;
Press «ENTER»;
Enter valid master code and press «ENTER»
2.8 Programming of Time delay and Opening time window.
The time delay (TD) function refers to the period of time which must
elapse before the lock can be opened. The opening time window (OTW) is
the period during which the lock may be opened after the TD has elapsed.
Any valid code can be provided with a TD or OTW function.
Press «ENTER»;
Press «6»;
Press «ENTER»;
Enter valid user code or master-code and press «ENTER»;
Enter a 2-digit number that will stand for the TD (01 -99 minutes) and a
number for the OTW (1-9 minutes). For example: 092 – 9 minutes for
TD, and 2 minutes – for the OTW.
Opening with the help of the programmed TD and OTW.
Press «*»;
Input valid user-code or master-code: green visual signal
Automatic start of TD: red visual and acoustic signals every 5 seconds
After end of TD – acoustic signal
Automatic start of OTW: green visual and acoustic signal every 5
seconds
Enter valid code once again during OTW: green visual signal
By pressing «ENTER» during TD period this function is interrupted. The
entire sequence must then be repeated in order to open again.
Cancellation of programmed TD/OTW
Press «ON» ;
Press «ENTER» ;
Press «6» ;
Press «ENTER» ;
Input valid user or master code and press «ENTER»;
Input 0-0-0 for cancelation of TD and OTW.
2.9 Sound O/ On
Push «ON» button ;
Push «ENTER» button ;
Push «5» button ;
Push «ENTER» button ;
Input the actual master-code and push «ENTER» button; Acoustic and
light signals are the same as when programming the master-code.
3. INSUFFICIENT POWER SUPPLY
Low voltage is shown by the red LED and quintuple acoustic signal. There
is still sucient energy for opening. Any change of code is not possible
whilst a low battery indication is displaying.
4. ERROR DIAGNOSES WHEN CHANGING THE ACTUAL
MASTER CODE.
This is the service function and it is indispensable for authenticity of the
master-code input.
Push «ON» button;
Push «ENTER» button;
Push «4» button;
Push «ENTER» button;
Input the service-code «160400» and push «ENTER» button;
If the lock has ever been opened with the help of the actual master-
code, after pushing «ENTER» button-quintuple buzz will follow and the
green L.E.D./ will blink 5 times.
V1 FEB 2019
FS1920E OPERATING INSTRUCTION
& GUARANTEE REGISTRATION
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Phoenix FS1922 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Phoenix FS1922 in de taal/talen: Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 0,83 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info