63049
2
Verklein
Vergroot
Pagina terug
1/4
Pagina verder
Philips Institutional TV Software
Philips Institutional Televisions can be configured to operate in either "Consumer" or "Commercial" operational modes. The master setup remote
is required to identify and set these modes. The master setup remote is also required for using or configuring other iTV products and accessories.
Commercial Mode: Philips Institutional Televisions are typically configured at the Factory to operate in Commercial mode. When the television
is in Commercial mode, access to its operation from its front panel controls or from a guest-mode remote can be limited, depending upon the set-
tings of the Institutional TV features. For examples, the unit’s front panel controls can be “locked-out” (rendered inoperable), only certain chan-
nels can be selected, and/or the volume can be limited to a given range.
Consumer Mode: When in the Consumer mode, the unit operates as a standard TV, bypassing the Institutional Television feature set, thus allow-
ing normal initial power ON, channel selection, and volume control (as well as a variety of selectable Menu features). When the TV is in Consumer
mode, Philips RC-5 system 0 (guest-mode) remotes, such as the RC2524BK and the RL9820BK (optional accessories) can access the Consumer-
mode Main Menu, and configure the television to the full extent offered in this mode. Guest-mode 21-button remotes such as the RC2524BK use
the Menu button to access the Consumer menu. Guest-mode 20-button remotes such as the RL9820BK, which do not have a Menu button, use the
Sleep button to access the Consumer menu. Simultaneously pressing the front panel’s Volume - and Volume + buttons also invokes the Consumer
menu.
Identifying the Operational Mode: To identify the television’s operational mode, a system 7 (commercial setup mode) master setup remote
(optional accessory, RG4172BK or RC2573GR) must be used. First, place the setup remote in setup mode. To place the the RG4172BK in setup
mode, press TV SETUP. To place the the RC2573GR in setup mode, set the switch to the TV SETUP position. Then press Recall. Television
status information similar, but not necessarily identical to the following will appear on-screen.
NOTE: THE ACTUAL STATUS SCREEN WILL VARY DEPENDING UPON THE MODEL AND MANUFACTURE DATE OF THE
SPECIFIC PHILIPS INSTITUTIONAL TELEVISION.
Changing Operational Modes: To change the television’s mode between Consumer and Commercial modes, a system 7 (commercial setup mode)
master setup remote must be used. Only a setup remote in setup mode can change the television’s mode between Consumer and Commercial, and
provide complete access to the television’s Institutional Features. The RG4172BK / RC2573GR can be set to operate in either its master setup
remote mode, or in guest-mode. With the RG4172BK in setup mode (press TV SETUP on the RG4172BK, or set the switch to the TV SETUP posi-
tion on the RC2573GR), enter the following keystroke sequence: 0 2 4 9 9 5 Menu. The RG4172BK / RC2573GR guest mode facilitates testing
the desired Institutional / Commercial configuration.
IMPORTANT NOTE: If you change the operational mode, you must power the television off and back on to complete the mode change.
Once the television is in consumer
mode, do not use the setup remote to activate commercial features. Otherwise, the commercial features
will affect consumer operation. It will then be necessary to place the television back into commercial mode, then into consumer mode, and
then powered off again to properly place the television back into consumer mode.
Accessing The Philips Institutional Television Menu
Regardless of the operational mode in which the Philips Institutional Television has been placed, its control settings and features can be accessed
by placing the RG4172BK / RC2573GR setup remote in setup mode and pressing the M (menu) button. If the television is in Commercial Mode,
the Institutional features will be accessible. On the following page, a typical late-model menu is shown. The specific items contained in the menus
of your Philips Institutional television will vary depending upon the operational mode and the model and manufacture date of the specific Philips
Institutional television.
Using The Setup Remote With Other Philips iTV Products
Your RG4172BK / RC2573GR setup remote is used with and/or required for a variety of other Philips Institutional Television products and acces-
sories, including Philips Institutional Televisions, SmartLoader Clone Boxes (RL9820BK / CLON99BK), and Philips iTV SmartCards (Net1Card,
Net3Card, etc.). Later in this guide there are brief summaries describing the use of the RG4172BK / RC2573 with selected accessories. Please
consult the documentation for the respective television or accessory products with which the RG4172BK / RC2573GR is to be used.
RC2573GR DFU # 3135-xxx-xxxxx 08/12/02
2
STATUS ITEM STATUS DATA MEANING
SYSTEM STATUS (LO1ITV-US4PV)
Information title
MODE COMMERCIAL / CONSUMER
Operational mode
CHANNEL CHANNEL, INPUT (CHANNEL, INPUT)
Currently-tuned channel / input
DCM OFF / ON
Data Communications Module offline / online
CODES 209 222 1 33
Internal data for factory / service use.
SIGNAL TUNED / NOT TUNED
Valid signal present / absent
OP HRS 0031h
Number of cumulative hours unit has been in
operation (hexadecimal).
ERRORS 0 0 0 0 0
Internal data for factory / service use.
VERSION 3.3
Television microprocessor software version.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Philips RC2573GR bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Philips RC2573GR in de taal/talen: Engels als bijlage per email.

De handleiding is 0,26 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info