683975
2
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
_______________________________________________________________________________________________________________________________________________________ BA GSxx00mod TSxx00mod Hardware N; de, en -23876- 2018.09.V01 ED
INSTRUCTION MANUAL AIR QUALITY SENSORS GS 4X.00 MOD / GS 3X.00 MOD / TS 3X.00 MOD HUGO MÜLLER GMBH & CO KG, STURMBÜHLSTR. 145-149, 78054 VS-SCHWENNINGEN
SAFETY INSTRUCTIONS AND BASICS
GS
40.00 mod / GS 30.00 mod /
TS 30.00 mod
Technical data
Safety instructions / Intended use
Power supply:
Bus current:
12-40 V DC
< 20 mA
CAUTION!
DANGER OF FIRE AND ELECTRIC SHOCK!
!!!Installation and assembly of electrical equipment must be carried out only by a skilled person!!!
Protocol / Interface:
Modbus ASCII, Modbus RTU / RS 485
Connect only to suitable supply voltage [12-40 V DC].
Warranty void if housing opened by unauthorized person!
The electronic circuit is protected against a wide range of external influences. Incorrect operating may occur if external influences exceed certain limits!
Installation and assembly of electrical equipment must be in accordance with national building, electrical and safety codes!
Defective devices / sensors have to be put out of service immediately!
Observe the regulations and instructions in the ZVEI/ZVEH handbook (building system technology). Especially the professional installation of the bus lines and the
professional instal
lation and start-up of KNX devices must be observed!
The device fits for the particular use of the following tasks: monitoring of the air quality in building systems technology (schools, offices, hotels, conference venue
etc.), data transfer and regula
tion via bus system.
The device is intended for use in accordance with the defined technical data.
Operate the device exclusively in a dry room!
The device is not qualified for security relevant tasks such as emergency doors, fire protection equipment, fermenting cellars etc.
Baud rates:
4800, 9600, 19200 (Default), 38400
Parity settings available:
None, even, odd
Sensors (depending on model):
CO
2
, relative humidity, temperature,
atmospheric pressure
Measuring range CO2 concentration:
39010.000 ppm (GS 4x only)
Measuring range relative humidity:
0100% (GS 4x, GS 3x only)
Measuring range temperature:
050°C
Measuring range atmospheric pressure:
absolute atmospheric pressure (GS 4x, GS 3x only)
Permitted ambient temperature :
-0°…+50°C
Housing:
self-extinguishing thermoplastic
Mounting:
Wall
Type of connection :
Push-in connector
Type of protection :
IP 20 to DIN EN 60529
Class of protection:
III when installed according to regulations
Source of interference
Inappropriate use / disposal
Device configuration (example)
The measurement results of the device can be
negatively influenced by external factors. Possible
sources of interference are:
■ Draught and air movement: e.g. through windows,
doors, convection, heating and people
■ Warming and cooling: e.g. sunlight or mounting on
an outside wall
■ Heat sources: close to installed electrical
consumers
e.g. dimmers
Vibrations or shocks, which the unites are or were
subjected to
■ Pollution due to colors, wallpaper paste, dust e.g. at
renovation work
Organic solvents or their vapours: e.g. detergents
■ Plasticizers from stickers and packaging: e.g. bubble
wrap or polystyrene
The device is not intended for use of unauthorized constructional alterations, repairs and
security relevant tasks
The device is not intended for use in outdoor areas and wet rooms
The device is not qualified for security relevant tasks The controlling of the device is only
for the observation and regulation of the air quality
The inappropriate use of the device can cause damage to property and persons
The device has to be disposed in an environmentally friendly manner according to the
current electrical codes!
ASSEMBLY
Assembly
Disconnect device from power supply for wiring and installation
purposes! Check power supply is disconnected!
Attention! You have to check and consider the safety instructions above!
This device is suitable for wall mounting or for mounting on a flush-mounting
box.
The device should not be exposed to dusty environment.
Ensure that no dust get inside of this device.
After initial startup, the device requires up to 5 minutes until the first correct
measurement is possible
STEP 1: Open the device at the bottom and remove the front cover.
STEP 2: Mount the rear cover to the wall or on a flush-mounting box
STEP 3: Connect the RS 485 Modbus serial cable and configure device according to the
project definition (address, baud rate…). Afterwards connect the power supply
STEP 4: After completing the installation the front cover must be reattached
Installation note: Make sure that no wires are pinched or squeezed when installing the cover. The mounting of the device on a flush-mounting box is recommended for easier handling and wiring.
Power / Status LED: Green: In operation / Power on
Flashing green: False / faulty configuration (DIP-switches)
Red: Active bus communication
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Muller GS 30.00 mod bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Muller GS 30.00 mod in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 0,55 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info