1. At the command prompt, execute the command readscript. Observe the optional command extensions.
2. As soon as you have called up all of the required sections of the configuration, stop the recording with the menu
item Transfer / Capture Text / Stop.
The configuration commands are now available as a script file and can be altered as required.
Download script from device
Installations with multiple LANCOM devices often profit from the automatic execution of certain configuration tasks.
The scripting function in LANCOM enables entire sets of commands for device configuration to be stored in a single
file—a script—for transfer to one or more devices in one step.
5
Detailed information about scripting can be found under the section 'scripting' in the chapter on Network
Management with LANtools in the reference manual.
In addition to manually setting a script and console read-outs, script files can also be read out from a device with the
help of LANconfig. For this, right click on the corresponding entry in the device list and select the entry Configuration
management / Save script to file from the context menu. Select the following options here:
1
Numeric sections
Enable this option if you do not want the configuration sections in the script to be displayed in cleartext (e.g.
/setup/wlan/ppp), but numerically (/2/2/5).
1
Default parameters
Unless defined otherwise, the only parameters saved in a script are those that deviate from the default values. Enable
this option if the standard values should also be entered into the script.
1
Column names
Unless defined otherwise, the fields of a table are initially entered as column names in the scripts and, thereafter,
only the respective values are inserted into the rows. Enable this option when every value in the table should explicitly
receive the description of the column in which it is inserted.
1
Comments
Activate this option when additional comments should be included in the script file.
1
Compact formatting
2
Enable this option if spaces and tabs should be suppressed.
1
Download only selected sections
Without further entries, the entire device configuration will always be saved in the script. In contrast, entering the
sections also makes it possible to save partial configurations. Enter the sections to which the script should be
transferred into this field, e.g. /setup/wlan.
3.9.4 Uploading configuration commands and script files
There are two basic methods of uploading the script commands to the intermediate memory of the LANCOM:
1
The commands can be manually entered at a console in script mode (with the command "beginscript"). In this way
the commands are written directly from the console to the intermediate memory. After all of the commands are
ready, they are processed by entering the command "exit" and are then transferred to the RAM.
1
The required command sequence can be saved to a text file. This text file is then sent to the intermediate memory
by using an appropriate tool (LANconfig, terminal program, TFTP). If the necessary commands are included in the
file, the transfer of the configuration to the RAM will be started automatically.
There are various ways to upload script files to LANCOM devices, the choice of which depends upon the configuration
tool that you prefer to use.
72
Reference Manual
3 Configuration
72

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Lancom LCOS 9.10 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Lancom LCOS 9.10 in de taal/talen: Engels als bijlage per email.

De handleiding is 54,4 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info