5 / 36 ENGLISH
Remove the reservoir lid by its handle
(Fig. 3, point 1).
Fill the reservoir with clean distilled or
demineralised water up to a maximum
40°C (Fig. 3, point 2). For best humidi-
cation and product lifetime, make sure
that the water level is still between the
minimum and maximum levels shown in
the reservoir (Fig. 1-2).
Replace the cover (Fig. 3, point 3).
PLEASE NOTE
DO NOT ll the reservoir above the indi-
cator showing MAX lling level.
DO NOT pour the water into the base
through the exhaust vent (Fig. 2, point 14).
DO NOT pour essential oils on to the pro-
jection lens (Fig. 2, point 17).
Air humidication function
With dry hands, insert the end of the
adapter in the DC jack socket located on
the back of the diuser (Fig. 1, point 3).
The humidier is tted with 3 mist in-
tensities:
·
Press the humidication button (Fig. 1,
point 6) once: the light is green and hu-
midication has been activated at the
lowest intensity (120 ml/hr);
·
Press the humidication button twice: the
light is blue and humidication has been
activated at medium intensity (150 ml/hr);
·
Press the humidication button three
times: the light is red and humidication
has been activated at the highest inten-
sity (180 ml/hr);
·
Press the humidication button four
times: the light goes out and humidi-
cation stops.
·
When the reservoir is empty, the light ashes
red (x) and humidication stops automa-
tically. The other functions remain active.
Use of essential oils
To diuse organic essential oils in the room,
pour a few drops of organic essential oils
(maximum -) directly into the water and
then put the lid back on the reservoir (Fig.
, point ).
WARNING
ADDITIONAL INFORMATION RELATING TO
THE USE OF ESSENTIAL OILS
Before using essential oils, please check
the harmful eects that use of these prod-
ucts may have on your health.
Always choose quality essential oils that
are pure, 100% natural and intended for
diusion. Use them in moderation and
with care. Follow the instructions and
warnings stated on the packaging of the
essential oils, in particular noting that:
·
Pregnant women, people with epilepsy,
asthmatics and people who suer from
allergies, those with heart problems
or serious illnesses should not use es-
sential oils.
·
Essential oils should be used only for
periods not exceeding 10 minutes in
the room of a baby (under 3 years old)
and only when the baby is not actually
in the room.
Make sure that children and minors do
not play with or use the device.
Just a few drops (3 to 4 drops at most) of
essential oils are sucient to ensure that
the device works properly and the scent
is diused. Excessive use of essential oils
could damage the device.
Lanaform cannot be held liable in the
event of accidental damage resulting from
any use contrary to the instructions given
in this manual.
Nightlight function
Press the nightlight button (Fig. 1, point
12) once: the light switches on and the
nightlight mode is active;
Press the nightlight button twice: the light
switches o and the nightlight mode is
disabled.
Light projection function
Press the projection button (Fig. 1, point
5) once: the light is blue and the active
light projection active for a period of 20
minutes;
Press the projection button twice: the
light is green and the light projection is
active continuously;
Press the projection button three times:
the light goes out and the light projection
is disabled.
PLEASE NOTE: EVEN THOUGH
THERE IS A SAFETY DEVICE THAT
STOPS THE TRANSDUCER FROM
WORKING, DO NOT LEAVE THE DE-
VICE CONNECTED WHEN YOU ARE
NOT USING IT.
MAINTENANCE AND STORAGE
Always switch o the humidier and empty
the water in the reservoir before cleaning
or storing it.
If the water is hard, i.e. if it contains too much
calcium and magnesium, it may leave a “white
powder” in the device and cause frothing on
the surface of the basin, on the transducer
(ceramic pellets producing ultrasound) and
on the internal walls of the water reservoir.
Frothing on the surface of the transducer
means that the device will not work properly.
We recommend:
1 Using water that has been boiled
and cooled or distilled water
each time the device is used,
2 Cleaning the reservoir every 3 days and
cleaning the transducer every week,
3 Changing the water in the reservoir
regularly so that it stays fresh, and not
leaving it there for longer than 2 days,
4 Cleaning the entire device and
making sure that all its parts are
completely dry when it is not in use.
To clean the transducer:
1 Turn the mist conductor (Fig. 1,
point 9) anti-clockwise until the
release markings are aligned,
then remove the conductor
2 Place 2 to 5 drops of vinegar on its
surface and leave for 2 to 5 minutes.
3 Brush the foam o the surface
with a soft brush. Do not use a
hard tool to scrape the surface.
4 Rinse the transducer with clean water.
5 Do not use soap or other basic
substances to clean the transducer.
To clean the basin:
1 Clean the basin with water using a soft
cloth and vinegar if there are foam
OR limescale deposits on the inside.
2 If the foam covers the safety
switch, put a few drops of vinegar
on it and clean it with a brush.
3 Rinse the basin in clean water.
STORAGE:
1 Clean and dry the humidier care-
fully using ultrasound, following
the maintenance instructions.
2 Let it dry completely before
storing it. Do not store it if there
is still water in the base.
3 Store the device in a dry, cool place
out of the reach of children.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Lanaform LA120122 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Lanaform LA120122 in de taal/talen: Nederlands, Duits, Engels, Frans, Pools als bijlage per email.

De handleiding is 1,8 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info