3) The input sensitivity of the two amplifiers
needs to be adjusted independently. To
properly calibrate the amplifiers for
maximum, identical, clean output, please
refer to Appendix A (page 14). After using this
procedure, you can then adjust the level of the
amplifiers by adjusting the input sensitivities
downward, if the amplifiers require attenuation
to achieve the desired system balance. If the
input sensitivities are adjusted, the amplifiers
must be recalibrated to ensure identical power
output levels.
Note: TheInput Rangeswitch on all “Slave”
amplifiers needs to be set toLow”, even if
the “Master” amplifier is high voltage and its
switch is set to “High”. All signals passed out
of the preamp outputs of the amplifier are
compatible with the Low” setting on the Input
Range” control.
The “Signal Sensing” turn-on feature will not
work on “Slave” amplifiers, but “Slave” amplifiers
can be turned on and off by a “Master” amplifier
operating in signal sensing turn-on mode.
Simply connect the “Master” amplifier’s
Remote” connection, to the “Slave” amplifier(s)
Remote” connection(s).
Do not increase the “Input Sens.setting for
any amplifier in the system beyond the maximum
level established during the procedure outlined
in Appendix A (page 14). Doing so will result in
audible distortion and possible speaker damage.
4) If you would like to run a third amplifier in
“Slave” configuration, select the Full-Range
position on the “Output Mode” switch of the
first “Slave” amplifier. Then, connect an RCA
cable from the first “Slave” amplifier’s preamp
outputs to the second “Slave” amplifier. As
you did with the first “Slave” amplifier, set the
second “Slave” amplifier’s “Amp LP Filter” to
the “Off” position. Then, calibrate the third
amplifier’sInput Rangeand “Input Sens.
controls in the same manner as you did for the
second amplifier.
Additional amplifiers may be added to this
“Master/Slave” configuration following the same
procedure as in step 4.
Once you match the input sensitivities of
all the amplifiers, you can use the “Master”
amplifier’sAmp LP Filter” and “Advanced
Bass Control” features to control the “Slave”
amplifier(s). If the remote bass control (RBC-1) is
used, it need only be connected to the “Master”
amplifier to control all the amplifiers in the
“Master/Slave” chain.
Reference the diagram showing a “Master/
Slave” configuration with one “Master” (top
amplifier) and two “Slave” amplifiers. Switches
and controls that are defeated in the “Slave
amplifiers are printed in gray.
APPENDIX D:
Master/Slave Configurations
With the flexible on-board crossovers and
processing incorporated into the 600/1v3, it
is possible to connect multiple 600/1v3’s in a
“Master/Slave” configuration, with each amplifier
driving its own speaker system but controlled by
the processing and filtering of only one amplifier.
This is very useful when driving multiple
subwoofers with multiple amplifiers.
To create a Master/Slave configuration, first
determine which amplifier will be the “Master”
amplifier and connect the main input signal to
that amplifier (from the source unit or from an
outboard processor). This amplifier’s “Amp LP
Filter” section and “Advanced Bass Control
features will process the signal for the “Slave
amplifier or amplifiers.
Here is the procedure for implementing a
“Master/Slave” configuration:
1) Set the “Master” amplifier’s “Output Mode
switch to the center “Amp Filter” position.
This will send a parallel, mono-summed signal
from the “Master” amplifier’s “Amp LP Filter
section to its preamp outputs.
2) Connect an RCA cable from the “Master
amplifier’s preamp outputs to the main input
of the first “Slave” amplifier. Set the “Slave
amplifier’sAmp LP Filter” to the “Off
position. This will defeat the LP filter and the
bass processing of this “Slave” amplifier.
MASTER:
+12VDC Ground Remote Preamp Output Section
Infrasonic Filter
“Q” Center Freq. Boost (dB)
Amp LP Filter
Advanced
Bass
Control
Amplifier Input Section
Subwoofer Output
MONO OUTPUT ONLY
Left Output Right Output Left Ch. Right Ch.Filter Freq. (Hz) Filter Freq. (Hz)Infrasonic Freq. (Hz) Remote Bass Port
Full Range
|
Amp Filter
|
Out Filter
Output Mode Filter Slope Mode
Mode
|
Slope
Input Voltage Input Sens. Signal Sensing
12dB
|
24dB
Filter Mode
LP
|
HP
Bass EQ
Off
|
On
Off
|
12dB
|
24dB Low
|
High Off
|
OnOff
|
On
40
45
55
65
80
100
200 15
18
22
30
45
55
60 40
45
55
65
80
100
200
0.5
0.7
1.1
1.6
2.7
4.3
20
25
30
40
60
75
80 0
+4
+10
+13
+15
60 0 /1v3
Monoblock Subwoofer Amplifier
+12VDC Ground Remote Preamp Output Section
Infrasonic Filter
“Q” Center Freq. Boost (dB)
Amp LP Filter
Advanced
Bass
Control
Amplifier Input Section
Subwoofer Output
MONO OUTPUT ONLY
Left Output Right Output Left Ch. Right Ch.Filter Freq. (Hz) Filter Freq. (Hz)Infrasonic Freq. (Hz) Remote Bass Port
Full Range
|
Amp Filter
|
Out Filter
Output Mode Filter Slope Mode
Mode
|
Slope
Input Voltage Input Sens. Signal Sensing
12dB
|
24dB
Filter Mode
LP
|
HP
Bass EQ
Off
|
On
Off
|
12dB
|
24dB Low
|
High Off
|
OnOff
|
On
40
45
55
65
80
100
200 15
18
22
30
45
55
60 40
45
55
65
80
100
200
0.5
0.7
1.1
1.6
2.7
4.3
20
25
30
40
60
75
80 0
+4
+10
+13
+15
60 0 /1v3
Monoblock Subwoofer Amplifier
+12VDC Ground Remote Preamp Output Section
Infrasonic Filter
“Q” Center Freq. Boost (dB)
Amp LP Filter
Advanced
Bass
Control
Amplifier Input Section
Subwoofer Output
MONO OUTPUT ONLY
Left Output Right Output Left Ch. Right Ch.Filter Freq. (Hz) Filter Freq. (Hz)Infrasonic Freq. (Hz) Remote Bass Port
Full Range
|
Amp Filter
|
Out Filter
Output Mode Filter Slope Mode
Mode
|
Slope
Input Voltage Input Sens. Signal Sensing
12dB
|
24dB
Filter Mode
LP
|
HP
Bass EQ
Off
|
On
Off
|
12dB
|
24dB Low
|
High Off
|
OnOff
|
On
40
45
55
65
80
100
200 15
18
22
30
45
55
60 40
45
55
65
80
100
200
0.5
0.7
1.1
1.6
2.7
4.3
20
25
30
40
60
75
80 0
+4
+10
+13
+15
60 0 /1v3
Monoblock Subwoofer Amplifier
Connect Master 600/1v3 Preamp Output to Slave A 600/1v3 Input
Connect Slave A 600/1v3 Preamp Output to Slave B 600/1v3 Input
Connect Master 600/1v3 Input to Signal Source
The Master amplifier’s
Advanced Bass Control” section
is active and affects all three
amplifiers equally.
The last Slave amplifier’s
Advanced Bass Control”
section, AMP LP Filter and
“Preamp Output”
are inactive.
This Slave amplifier’s
Advanced Bass Control” section
and AMP LP Filter are inactive,
but the Full-Range (pass-
through) feature of its “Preamp
Output” feeds the input of the
next Slave amplifier.
SLAVE A:
SLAVE B:
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw JL Audio 600 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van JL Audio 600 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,72 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info