SAFETY PRECAUTIONS
Wrist Blood Pressure Monitor
Instruction Manual
Monitor
Display
Package Contents
• One Touch Operation
• 99 Total Memory
• Auto-off Power Saving Feature
• Operated by 2 AAA batteries
Memory recall
button
On/Off button
Battery
Compartment
2 3 4
M
M
OVERVIEW
Features
Babies, young children or individuals who cannot express
their consent are not suitable to take blood pressure
measurement.
Individuals with serious arteriosclerosis are not suitable to
take blood pressure measurement.
Blood pressure readings may change in case of pregnancy.
Pregnant women can consult their doctor before taking
measurement.
Self-measurement is not medical treatment. If there are
unusual values, please consult your doctor.
Handling batteries properly:
- As soon as old batteries run out, replace with new
batteries.
- Do not use old and new batteries together.
- Align the polarities of batteries correctly.
- When the unit will not be used for more than 3 months,
remove the batteries. Otherwise, batteries may leak and
cause damage to the unit.
SYS.
mmHg
DIA.
mmHg
Pulse
/min
MemoryMemory
M
5. When the measurement is complete,
the cuff will automatically deflate and
your systolic and diastolic pressure
values and pulse rate will display.
Avoid smoking, eating or exercising for 30 minutes before
taking measurement
1. Sit upright in a chair with your both
feet on the floor.
2. Roll up the sleeve to bare your wrist
if necessary. Take caution not to
constrict the blood flow.
3. Pull on the end of the cuff until it wraps
securely around your wrist. Place your
elbow on a table so that the monitor will be at the same
level as your heart.
4. Press the “ ” button. The cuff will automatically inflate and
the measurement will start.
After measurement, the last set of measured values will be
saved automatically after measurement when the unit is
turned off by pressing Power button or by automatic power
off after 3 minutes.
9
MEMORY FUNCTIONS
User can delete all the past readings stored in memory by
replacing the batteries.
4.2 Delete Past Readings
4.1 View Past Readings
1. Press the “Memory button to enter memory function.
2. Press the “Memory button to display the next sets of
values. Past readings are displayed from the most recent
to the oldest.
3. This can stored up to 99 sets of past readings.
Package Content Instruction Manual, Battery Set,
Warranty Card
Model No. DW 500
Measurement Method Oscillometric
Measurement Range Pressure: 20 – 280 mmHg
Pulse Rate: 40 – 195 beats/min
Accuracy Pressure: +/- 3 mmHg
Pulse Rate: +/- 5%
Inflation Pump driven
Pressure Detection Semi-conductor
Power Supply 2 x AAA batteries
Auto Power Off 3 minutes after last operation
Storage Environment -20°C to 60°C, 10% to 95% RH
Operation Environment 10°C to 40°C, 30% to 85% RH
External Dimensions 3.15” (L) x 2.95” (W) x 2.36” (H) or
80 x 75 x 60 mm
Net Weight 126 g (batteries excluded)
Cuff Dimensions For wrist circumference of
13.5-19.5 cm
TROUBLE SHOOTING
Note: If your problem cannot be solved by the above,
consult your store of purchase. Do not disassemble
the unit.
SPECIFICATIONS
10 11 12
STORAGE & MAINTENANCE
Note: Subject to modification without prior notice.
Remove batteries from the unit when it will not be used for
more than 3 months.
Use a dry, soft cloth to clean the unit, or if desired, use a cloth
lightly dampened with water.
Keep away the unit from direct sunlight, extreme
temperatures, humidity or moisture.
Do not use alcohol, benzene, thinner or other volatile liquids
to clean the unit.
Do not wash or expose the arm cuff to liquid.
No display when
you press the
Power/Start button
Have the batteries
run out?
Replace new
batteries.
Are the battery
polarities wrong?
Re-align batteries
in correct polarities.
“Err P” displayed
Check if the cuff is
properly connected.
Replace the air tube
if it is broken.
“Err 1” displayed Deflate too rapidly
Return for servicing.
“Err 2” displayed
Movement during
measurement
Do not move during
measurement
Signal interference
Remove interfering
source e.g. mobile
phones, magnets.
“Err 3” displayed Incorrect results Measure again.
Fail to inflate
SolutionProblem Cause
QUICK START GUIDE
Memory
Low Battery
Indicator
Pulse symbol
Systolic
Diastolic
Pulse
Memory No.
(1~99 readings)
Note:
- Avoid smoking, eating or exercising for 30 minutes before
taking measurement.
- Do not move or talk during measurement.
- Measurement can be taken on either arm.
1. Relax
2. Sit upright in a chair with your both feet on the floor.
3. Remove tight fitting clothing from you upper arm and
thick clothing. Do not roll up your sleeve if it is too tight.
4. Place your arm on a table so that the cuff will be at the
same level as your heart.
2. Pull on the end of the cuff until it
wraps securely around your wrist.
Do not over tighten the cuff.Allow
1 cm or ½ inch between the bottom
of the cuff and the crease of your
wrist.
1. Squeeze slightly and pull to
remove the battery cover.
2. Insert 2 AAA batteries with
the polarities in correct
direction.
3. Replace the battery cover.
Press it lightly until the lock
securely clicks into place.
6 7 8
BATTERY INSTALLATION
3 TAKING MEASUREMENT
3.1 Sitting Correctly
3.2 Applying the Wrist Cuff
1. Place your elbow on a table and palm facing upward, and
wrap the cuff around the left wrist.
3.3 Taking Measurement
Besides Systolic and Diastolic
values, Pulse will also be displayed
after a measurement.
3.4 Heartbeat Reading
M
pulse
3. Remove the arm cuff and take note of your measurement
results.
2. When the measurement is complete, the cuff will
automatically deflate and your systolic and diastolic
pressure values and pulse rate will display.
1. Press the “ ” button. The cuff will automatically inflate
and the measurement will start.
NoteYou can press the “ ” button to stop measurement
at any time.
Note: Replace batteries when the battery indicator “ ”
shows low voltage.
5
3. Make sure the cuff is at the same level as your heart.
Manufactured in accordance with International Standards
ManufacturerTruly Instrument Ltd - Hong Kong
EC-RepresentativeHong Kong Truly Semiconductor Ltd.
1-2 Alpha Buildings, The Buntings Kestrel Drive,
Stowmarket Suffolk, IP14 5GZ, UK
Main Unit
2xAAA
Alkaline Battery
SYS.
mmHg
DIA.
mmHg
Pulse
/min
MemoryMemory
M
SIZE:72*97MM 正面
SIZE:72*97MM 反面
0123
Importer: INOVAXION
10 rue Jean Cottin 75018 - Paris - France
Ref : INOTP04
Find our products on
www.inocare.fr

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Inocare DW500 - INOTP04 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Inocare DW500 - INOTP04 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,65 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info