The function of the mechanical release should be checked
every month. The pull cord with knob may only be actu-
ated when the door is closed, otherwise in the case of
weak, broken or defective springs or due to a deficient /
faulty counterbalance, there is a risk that the door could
close extremely quickly.
ATTENTION
Never hang bodily from the pull cord!
All persons using the door system must
be shown how to operate the garage door
opener properly and safely. Demonstrate
and test the mechanical release as well
as the safety return. To do this, halt the
closing door by grasping it with both
hands. The door system should gently
cut-out and initiate the safety return.
The same should happen during the
opening cycle, i.e. the door system
gently cuts out and the door comes to
a halt.
3.6.1 Normal operation
During normal operation the garage door operator works
exclusively on impulse sequence, whereby it makes no dif-
ference whether the external button, a programmed hand
transmitter button or the transparent button was pressed:
1st Impulse: Operator causes door to move towards
an end-of-travel position.
2nd Impulse: Operator causes door to stop.
3rd Impulse: Operator causes door to travel in the
opposite direction.
4th Impulse: Operator causes door to stop.
5th Impulse: Operator causes door to travel in the
direction of the end-of-travel position
selected when the first impulse was
generated
etc.
The operator lighting comes on when the door moves
and automatically goes out 3 minutes later on completion
of the cycle.
3.6.2 Operation following actuation of the mechanical
release
If, for instance due to a power failure, the mechanical
release was actuated, the carriage must be re- engaged
in the belt lock before normal operation can be resumed:
1) Move the operator until the belt lock in the boom is well
accessible for the carriage, and then stop the operator.
2) Press the green button on the carriage (see figure 19).
3) Move the door by hand until the carriage re- engages
in the belt lock.
4) Carry out several uninterrupted travel cycles to check
whether the door has fully reached its closed position
and whether it has also fully opened (the carriage comes
to a halt shortly before the OPEN limit stop).
The operator is now ready to resume normal
operation.
Note
If, after carrying out several uninterrupted travel cycles, the
behaviour/action does not correspond to that described
in stage 4, a new learn operation will be necessary (see
section 3.3.2).
3.6.3 Signals from the operator lighting
If the mains plug is inserted without the transparent
button (with operator cover removed the circuit board
button) being pressed, the operator lighting flashes two,
three or four times.
Flashing twice
indicates that no door data is stored or has been deleted
(as in the ex factory state): programming can then be
carried out immediately.
Flashing three times
indicates that door data is stored but that the last door
position is not sufficiently well known. The next travel
cycle is therefore an OPEN reference cycle. This is then
followed by "normal" travel cycles.
Flashing four times
indicates that not only is door data stored but also that
the last door position is sufficiently well known, so that
"normal" travel cycles taking into consideration the im-
pulse sequence (OPEN-STOP-CLOSE-STOP etc.) can
follow (normal behaviour following successfully comple-
ted programming and a power failure). For safety rea-
sons, whenever there is a power failure during a travel
cycle, i.e. when the door is still in motion, the first impulse
command always results in the door opening.
Note
An OPEN reference cycle can be enforced if, when the
mains plug is inserted, the external button (connected
at terminals 20 and 21a) is pressed. In this case, the ope-
rator lighting flashes three times.
Replacement lamp for operator lighting:
24 V/10 W, socket: B(a)15s
3.6.4 Error messages / diagnostic LED
(light emitting diode, see figure 10.1)
When operation does not go to plan, a diagnostic LED
(visible through the transparent button even with the
operator cover in place), helps you to easily identify the
possible causes. In the programmed state this LED nor-
mally glows constantly and goes out as long as an ex-
ternally connected IMPULSE device is activated (see
section 3.5.2).
Note
On the basis of the behaviour explained above, a short-
circuit in the connecting lead of the external button or a
short-circuit in the button itself can be recognised even if
normal operation of the garage door operator with the re-
mote control or the transparent button is otherwise possible.
42
06.2004 TR10A014 RE
42

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Hormann ProMatic P bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Hormann ProMatic P in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 4,94 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Hormann ProMatic P

Hormann ProMatic P Gebruiksaanwijzing en installatiehandleiding - Deutsch - 28 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info