Installing a domestic appliance can be a complicated operation which if not carried out correctly, can seriously affect consumer
safety. It is for this reason that the task should be undertaken by a professionally qualified person who will carry it out in
accordance with the technical regulations in force. In the event that this advice is ignored and the installation is carried out
by an unqualified person, the manufacturer declines all responsibility for any technical failure of the product whether or not
it results in damage to goods or injury to individuals.
2 GB
BUILT-IN
The furniture in whi ch your hob will be installed and all adjacent
furniture, should be made from materials that can withstand high
temperatures. In addition, all decorative laminates should be fixed
with heat-resistant glue.
Installation:
•A watertight seal is su
pplied with the hob.
Before fitting:
- turn the hob upside down, with the glass surface facing downwards.
Make sure the glass is protected.
- fit the seal round the hob.
-make sure that it is correctly fitted to avoid any leakage into the
supporting cabinet.
•Leave a gap of at least 5 cm between the appliance and the
vertical sides of the adjacent furnit
ure.
• If, when installing the hob, the lower hob face is adjacent to an
area normally accessible when handling or cleaning, fit a partition
1 cm below the base of the hob to avoid any risk of scorching
or damage.
INSTALLATION
"The installation must conform to the standard directives."
The manufacturer declines all responsibility for any damage that
may be caused by unsuitable or unreasonable use.
Warning :
• Always check before any electrical operation, the supply tension
shown on the electricity meter, the adjustment of the circuit-
breaker, the continuity of the connection to earth to the installation
and that the fuse is suitable.
• The electr
ical connection to the installation should be made via
a socket with a plug with earth, or via an omnipole cut-out switch
with an opening gap of at least 3 mm.
If the appliance has a socket outlet, it must be insta lled so that
the socket outlet is accessible.
The yellow/green wire of the power supply cable must be
connected to the earth of both power supply and appliance
terminals.
The manufacturer cannot be held responsible for any accidents
resulting from the use of an appliance which is not connected
to earth, or with a faulty earth connection continuity.
• Any queries regarding the power supply cord should be referred
to After Sales Service or a qualified technician.
ELECTRICAL CONNECTION
min 10 mm
Sp da 25 a 45 mm
Accessible
space
Seal
Hob
min 70 cm
min 15 cm
min 5,5 cm
10 mm
mini
50 mm
Opening
500 X 50
Opening
500 X 10
It is forbidden
to fit the hob
above a non-
ventilated oven
CONNECTION TO THE TERMINALS ON THE TERMINAL BLOCK:
SHUNT
The hob is fitted with a power supply cord which a llows it to be
connected only to a power supply of 220-240 V between phases
or between phase and neutral.
• Connect to a socket, to choose the correct fuse, you must
refer on the table.
It is however possible to connect the hob to :
. Three phase 220-240 V3~ . Three phase 380-415 V2N~
To proceed to the new connection, you must adhere the
following instructions.
• Before making the connection, make sure that the installa tion
is protected by a suitable fuse, see table, and that it is fitted with
wires of a large enough section to supply the appliance normally.
• Tu rn over the hob, glass side against the work top, taking care
to protect the glass.
• Open the cover in the following sequence:
1 2 3
unscrew the cable clamp "1",
•find the two tabs located on the sides,
•put the blade of a flat screw-driver in front of each tab "2" e "3",
push in and press, remove the cover.
To release the power supplying cord.
• remove the screws retaining the terminal block which contains
the shunt bars and the conductors of the supply cord,
•Pull out the supply cord.
Operations to be carried out to make a new connection :
- Choose the power supply cable in accordance with the
recommendations in the table.
-Pass the power supply cable into the clamp.
- Strip the end of each conductor of
the supply cord on a 10 mm length,
by taking in account the requested
length of the cord for the connection
to the terminal block.
- According to the installation
and with the help of shunt bars which
you should have recovered in the
first opera
tion, fix the conductor as
shown on the chart.
-Fix the cover.
- Screw the cable clamp.
Note: make sure the terminal board screws are tight.
Ph = Phase N = Neutral T = Earth
Monophase 220-240 V~
Two phases 220-240 V2~
Three phases 220-240 V3~ Three phases 380-415 V2N~
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Hoover hvh 551 b bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Hoover hvh 551 b in de taal/talen: Nederlands, Duits, Engels, Italiaans, Portugees, Spaans, Deens, Zweeds, Noors, Fins als bijlage per email.

De handleiding is 3,85 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info