CONTROLS THAT DO THE THINKING FOR YOU CONTROLS (CONTINUED)
Selecting Settings – Once you have tapped the POWER icon (
), tap the Cleaning Level icon (
) to select the
desired cleaning level. Your air cleaner will start on the General Cleaning setting each time you turn the air cleaner
on. Continue to tap the (
) icon to cycle through the cleaning levels to reach the desired setting. Here is a
handy reference to help get the most out of your air cleaner’s performance:
LEVEL 6 - MAX
Best for power cleaning when unpleasant odors are noticeable or you can sense that airborne particles are
present. This setting cleans the air the fastest of all the settings and circulates the air more frequently in the room.
LEVEL 5 - ALLERGEN
This setting makes the air cleaner perform at the proper level for reducing many types of airborne allergens.
It optimizes its performance for reducing allergens based on the particle size range of typical pollens. Best for
fighting airborne allergens during high allergen season, particularly in the spring and fall to help reduce airborne
pollen.
LEVEL 4 - PET
This setting optimizes performance to best capture pet hair and dander as well as reduce pet odors.
LEVEL 3 - GENERAL
Best for General Cleaning. Use this setting to help reduce airborne dust and smoke particles, like those from
cooking or tobacco smoke.
LEVEL 2 - GERM
This setting slows down air movement so airborne microscopic germs are most effectively captured in the filter.
Germs, like certain bacteria and viruses, can be much smaller than other airborne particles or organisms. Giving the
germs more time to dwell in the filter increases the filtration efficiency. This setting can be used during cold and flu
season to help reduce certain germs from the air that passes through the filter.
LEVEL 1 - SLEEP
Best for ultra quiet operation, perfect for nighttime use when sleeping.
Auto-off Timer
Auto Timer Display
Germ Reduction Setting
General Cleaning Setting
Filter Check Reminder
Sleep/Quiet Setting
Cleaning Level
Oscillation
Bluetooth® Indicator
Dimmer
Oscillate – To turn Oscillation on, simply tap ( ) once. To turn Oscillation off, tap ( ) again.
Auto-off Timer – The Timer Option (
) allows you to select how long the air cleaner will run before it
automatically shuts off. The timer can be set in one hour intervals from one to eighteen hours. Do not use this
option if you want the unit to run continuously.
• To set the unit for Automatic Shut Off, TAP (
)
TAP the up or down arrows ( ) to toggle through to the desired time setting
118 hours.
• The digital timer will indicate the selected run time (Fig. 3).
The LED Display will automatically count down and display the number of hours left
on the timer.
• The unit will automatically shut off after the indicated run time.
Dimmer – The Dimmer Option (
) allows you to adjust the brightness of the LED lights on the control panel. You
may wish to adjust the brightness depending on the room where the unit is placed. The unit always turns on with
the brightness on HIGH.
To adjust brightness:
• TAP the (
) once to dim the lights to LOW.
• TAP the (
) twice and it will shut the lights OFF (the air purifier will not shut off).
• TAPPING the (
) a third time will return the brightness to HIGH.
NOTE: The Power (
) and the Bluetooth ( ) icon will always remain illuminated.
Using the VOC Function The AirGenius 6 has a built-in sensor that detects when Volatile Organic Compounds
(VOCs) are present in the room air. VOCs are gases that are emitted from certain household cleaning, home
improvement, and even common household décor products. These gases can be harmful or irritating if inhaled.
When the VOC auto sensing mode ( ) is selected, the AirGenius 6 will automatically operate at the appropriate
cleaning level to reduce these gases.
TAP the VOC Auto Sensing mode icon ( ) for automatic operation based on VOCs sensed in the room air.
When the VOC Auto Sensing mode is selected, the circular LED readout in the center of the control panel will
illuminate in green, amber or red to indicate the unit is running in automatic VOC
sensing mode. (Fig 4)
Green = Low level of VOCs detected, air cleaner will operate on lowest setting, Sleep.
Amber = Moderate level of VOCs detected, air cleaner will operate in the medium level
setting, General.
Red = High level of VOCs detected, air cleaner will operate in the Max setting.
The AirGenius 6 will continue to monitor the VOC levels in the room and adjust the
cleaning levels as necessary.
Electronic Filter Check Reminder The AirGenius 6 has an electronic CHECK FILTERS light to
remind you when it is time to wash the ifD
®
Particle Filter and replace the ODOR & VOC Reducing
K
Pre-filter. The
CHECK FILTERS light will illuminate after 2160 hours (3 months) of operation. It is recommended that you clean/
replace the filters every 3 months. The 3 month cleaning interval is intended as a guideline only. Performance of any
filter media is dependent upon the concentration of contaminants going through the system. High concentrations of
contaminants such as dust, pet dander, and smoke will reduce the useful performance life of the filters.
VOC sensor Auto mode
Fig. 3
Fig. 4
Allergen Reduction Setting
Pet Setting
Max Cleaning Setting
Power
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Honeywell HFD360 Series - AIRGENIUS 6 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Honeywell HFD360 Series - AIRGENIUS 6 in de taal/talen: Engels, Frans, Spaans als bijlage per email.

De handleiding is 4,99 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info