6 HEAT SETTINGS THAT GIVE YOU CONTROL OF YOUR COMFORT
SAFETY FEATURES
TROUBLESHOOTING
Problem Solution
If your Honeywell HeatGenius
TM
Ceramic Heater shuts off
unexpectedly or fails to
operate, one of your heater
safety features may have
been activated to prevent
overheating.
Be sure it is plugged in and that the electrical outlet is working.
Check for any obstructions. If you find an obstruction, turn the heater
OFF (
) and unplug it.
Allow the heater to cool completely, then remove the obstruction.
Wait at least 10 minutes, then re-plug the heater in and follow the
OPERATION instructions.
Press and hold both Thermostat Control Buttons (
) for three seconds to change between Fahrenheit
and Celsius and back.
It is recommended that the Honeywell HeatGenius
TM
Ceramic Heater be cleaned at least once a month and
before off-season storage.
Turn Off (
) and unplug heater. Allow unit to cool.
Use a dry cloth only to clean the external surfaces of the heater. DO NOT USE WATER, WAXES,
POLISHES OR ANY CHEMICAL SOLUTION.
Before storing, clean the Ceramic Heater using the above-mentioned steps. Wrap the cord around the
unit. Place in its original box and store it in a cool, dry place.
This heater does not disassemble.
FAHRENHEIT TO CELSIUS
CLEANING AND STORAGE
Model(s) Unit dims Amps Unit
Voltage
Max
Watts
Max BTUs
HCE840B /
HCE840C
10.2” L x 5.6” W x 17.3” H 12.5 120V, 60Hz 1575 5118
PRODUCT SPECIFICATIONS
Fig. 3
Fig. 2
Low Heat
& "White
Noise"
Setting
2 Hour
Auto-off
Timer with
30 Minute
Phased
Intervals
6 Ways to Heat the Space You are In - Once your heater is ON, use the control buttons on the bottom to
select the desired heat setting for your needs. Your heater will start on the Constant Hi Room heat setting
each time you turn the heater on. Here is a handy reference to help select the heat option that best suits
your desired comfort level:
FLOOR AREA – (LOW HEAT)
This setting uses the lower level heating element only to provide a comfortable, gentle heat to warm up the
floor area in front of the heater.
PERSONAL – (MODERATE HEAT)
This setting uses a moderate heat level to warm you personally wherever you may be relaxing (reading,
watching TV, etc.). The LO option (
) provides a soothing heat level, while the HI option ( ) slightly
increases heat output, allowing you to adjust to your desired comfort level.
ROOM – (MODERATE-HIGH HEAT)
Best for whole room heating, use this setting to bring warmth to cooler, drafty rooms. The LO option
provides a moderate heat level, while the HI option uses maximum heat output to create a warmer
environment.
THERMOSTAT – (MODERATE-HIGH HEAT)
To set the Thermostat, press the Thermostat Control Buttons (
) to choose your Desired
Temperature. The Desired Temperature will flash five times and then the Current Temperature in the room
will display as a steady number. The Thermostat can operate on either HI or LO heat levels to achieve
Desired Temperature by pressing the (
) button under Room.
NOTE: If the Current Temperature is higher than your Desired Temperature, the heater will go into cool down
mode and then shut-off until the room temperature falls below this setting or until the Desired Temperature
is changed.
HEATPHASE™ TIMER
The new HeatPhase Timer is an auto-off feature that gradually transitions the room temperature from
warmer to cooler. The timer starts at high heat and steps down 4 different heat levels until it shuts off - over
a 2 hour period. This feature is ideal for setting a comfortable, relaxing environment. (Fig. 2) The timer can
also be toggled to start at whichever level desired.
QUIET MODE
The new Quiet Mode features uses a low heat setting and fan speed to produce a gentle "white noise" and
soothing warmth. (Fig. 3)
The Honeywell HeatGenius
TM
Ceramic Heater is equipped with several devices and features for
added protection:
A four way tip-over switch that disables the heater if it is accidently tipped in any direction. If tipped over,
the unit should be set upright and follow the OPERATION instructions.
A high temperature safety control prevents overheating. If activated, unplug the device and wait at least
10 minutes for unit to cool. Then plug the heater back in and follow the OPERATION instructions.
The heater is also equipped with a thermal cut-off fuse that will permanently shut down the heater should
it operate at a highter than normal temperature. If activated, the unit will need to be replaced.
This heater was created using high quality, heat-resistant plastics and has a Cool Touch handle.
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Honeywell HCE840 series bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Honeywell HCE840 series in de taal/talen: Engels, Frans, Spaans als bijlage per email.

De handleiding is 1,7 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info