RE-INVENTING THE HOME
HOME
easy
HE-440 Outdoor Remote
Control 4Gang Kit
V1.0
OFF: An additional safety feature of the HE440 is the ability to switch off the
power as per a normal socket.
Unused accessory Channels should be set to OFF
INSTALLATION WARNING:
ON INSTALLATION TURN OFF YOUR MAINS ELECTRIC SUPPLY
This product should be fitted by a competent person in accordance with the
instructions listed below and with the relevant clauses of the IEE wiring regulations
BS7671.
For fixed installation only
1. Remove the front cover by
unscrewing the front cover.
Installation Guide:
Wiring Remote Socket:
On the outdoor enclosure you will see that there are a number of rubber entry spaces
(‘Entry blanks’) on each side, depending on location and wiring setup a number of
these can be removed.
If installing the HE440 with conduit from the sides or top attachment, a 5mm hole
must be drilled through the bottom left drainage hole. This will allow for any
condensation forming in the conduit, to drain out.
Caution: opening the drainage hole will affect the IP rating of the product. Ensure that
jetted water is not directly sprayed onto the unit.
Do Not drill out the drainage hole when installing the Outdoor socket into a dusty
environment. Always install the unit via the bottom cable entry, making sure that a 5mm
hole is drilled into the lowest point in the conduit system.
The HE-440 allows you to control up to 4
separate outdoor electrical products
independently using the HomeEasy
remote control timer, with a maximum
combined load of 3000W.
AUTO: Allows the Remote Control to switch on/off
the HE440. See Pairing/Deleting with Remote
ON: Sets the Outdoor socket as a standard outdoor socket.
USE THIS OPTION WHEN USING GARDEN
MACHINERY SUCH AS A LAWNMOWER OR HEDGE CUTTERS.
-Selectable timer setting
-12 Programmable memory Settings
-Security Mode Setting
-Single and Daily Timer Functions
easy
HOME
The HE440 should be used in conjunction with a fused spur connection, all connections
to the socket need to be made as instructed, making sure that the cable used is
appropriate for the installation environment, free from stress & terminals are tightened
fully.
-Single and Daily Timer Functions
-IP56 Weather Proof
-30 Metre Wire Free Range
-CR2032/23A Battery (Included)
Product Specification:
4 Gang Remote Control Receiver: HE-440
Input: 230V - 240V ~50Hz
Range: 30 Metres (Open Distance)
Frequency: 433.92MHz
Max Load: 3000W
(Combined Resistive load)
IP56 (Lid Closed)
Warning: Never Exceed the Product Specification
Remote Control PIR: HE-403
Battery: 23A & CR2032 (Included)
Range: 30Metres (Open Distance)
Frequency: 433.92MHz
Indoor use only
3. Using the back half of the unit as a template, mark
all four corners onto your chosen surface. Insert
suitable wall plugs and secure to the wall using
number '8' screw (recommended size).
2: In the back half of the unit, in all four corners are
purpose made holes for fixing your HE440 to your
intended surface. The HE440 needs to be mounted
onto a flat, vertical surface, free from grease, loose
material and any corrosive substances. We
recommend a house or sturdy garden wall.
Recommended Setup:
Voltage In:
230-240V ~ 50Hz
Channel 3 Out
Channel 1 Out
Channel 2 Out
Channel 4 Out
Once removed the entry blanks
are removed, appropriate cable
glands need to be installed (not
included).
Input Power: (See Wiring Diagram)
1: Switch off and isolate the mains power before Installing or altering the
electrocal connections and remove the terminal covers.
2: Send the cable through the gland and into the HE440.
3: Cut back the cable to reveal the 3 separate wires
L= Live  Brown
E= Earth  Green & Yellow
N= Neutral  Blue
4: Now strip each wire, exposing 10mm of its core
5: Insert the exposed core wires into their related terminals
and clamp down by tightening the respective screw. replace
the terminal covers and tighten the cabel glands, making
sure wall wires are secure.
Wiring Diagram:
Accessory Output 1 Accessory Output 2 Accessory Output 3
Accessory Output 4
Input Power
230 - 240V ~50HZ
= Live  Brown
= Earth  Green & Yellow
= Neutral  Blue
The HE-200 Remote Control Timer can be paired with 16 separate
receiver units, to select the required unit code, press the unit
button unitl the required number is displayed.
Each unit code will indavidually can indavidually operate single
channel or all 4 channesl.
The HE-200 comes with a preset to Group code A. When
using additional remote control timers you will need to
select a new group code.
To select a new group code, remove the battery cover and
using a small screw driver, rotate the group dial to a new
setting e.g. Group B
HE440
HE200
WARNING:
You MUST install an earth cable between the origin of the installation and the earth
terminal of the outdoor socket. This must be insulated inside a sleeve protector within
the conduit.
If using metal conduit, earth continuity must be maintained between conduits. Seal
Conduit and conduit entry with a non setting conduit sealant. Purchasable form you
local electrical retailer.
Operating Mode:
Output:
230-240V ~ 50Hz
3000W Combined
6. Reconnect the mains power, the HE440 is now ready programming
(See Pairing/Deleting with Remote).
Replace the front cover and tighten the screws.
Each Acessory Output Channel can operate in 3 seperate modes, use the slide
switch on each channel to select the mode setting.
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Home Easy HE-440 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Home Easy HE-440 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,62 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info