Application
Thermostat mixers are designed for hot water supply via
pressurised storage heaters and, utilised in this way, provide
the best temperature accuracy. With sufficient power output
(from 18 kW or 250 kcal/min), electric or gas instantaneous
heaters are also suitable.
Thermostats cannot be used in conjunction with
non-pressurised storage heaters (displacement water
heaters).
All thermostats are adjusted in the factory at a flow pressure
of 3 bar on both sides.
Should temperature deviations occur on account of special
installation conditions, the thermostat must be adapted to local
conditions (see Adjusting).
Specifications
Minimum flow pressure without
downstream resistances 0.5 bar
Minimum flow pressure with
downstream resistances 1 bar
Max. operating pressure 10 bar
Recommended flow pressure 1 - 5 bar
Test pressure 16 bar
Flow rate at 3 bar flow pressure
34 361 approx. 41,5 l/min.
34 364 approx. 29,0 l/min.
Max. water temperature at hot water supply 80 °C
Recommended max. flow temperature (energy saving) 60 °C
Safety stop 38 °C
Hot water temperature at supply connection min. 2 °C higher
than mixed water temperature
Cold water connection right
Hot water connection left
Minimum flow rate = 5 l/min
If static pressure exceeds 5 bar, a pressure reducing valve
must be fitted.
Installation
Flush pipes thoroughly.
These installation instructions for thermostatic mixers are
applicable both to replacements and new installations.
In the case of a new installation, special accessories must be
ordered, i.e. ref. No. 12 419, 12 400 and 12 407 for a vertical
installation or ref. No. 12 400 and 12 407 for a horizontal
installation.
For Cat. Pos., see fold-out page II.
Install S-unions and outlet elbow.
Screw-mount the mixer securely, see fig. [1].
In this connection, refer to the dimensional drawings on fold-
out page I.
The outlet pipe (C) must be shortened to the appropriate
length.
Thermostatic mixers are assembled at the factory for a vertical
mounting position.
If a horizontal position is required, the mixer must be adapted
as follows, see fig. [2].
1. Remove union connection set (F), screw plug (D) and
cap with screw (E).
2. Reinstall the removed components on the mixer body, offset
about one union in the anticlockwise direction.
Mixer No. 34 364 can be converted to a shower mixer by
means of the outlet nipple (G) supplied, see fig. [3].
1. Remove union connection set (F).
2. Remove cap with screw (E) and install in aperture requiring
to be blanked off.
3. Install outlet nipple (G), supplied, in the mixer.
Test unions for leaks.
Reversed union (hot on right - cold on left).
Replace thermoelement (T), see replacement parts
fold-out page II, ref. No.: 47 282 (1/2”).
Adjusting
Temperature adjustment, see figs. [4] and [5].
Open the shut-off valve and check the temperature of the
water with a thermometer, see fig. [4].
With the safety stop depressed, turn temperature control
handle (J) until the water temperature reaches 38 °C, see
figs. [4] and [5].
- Remove cap (H), see fold-out page II.
- Hold temperature control handle (J) in this position and
unscrew and remove screw (I), see fig. [5].
- Pull off temperature control handle (J) and reinstall in such a
way that the 38°C mark on the knob coincides with the
mark (K) on the mixer body.
- Hold temperature control handle (J) and reinstall screw (I).
- Reinstall cap.
Temperature limitation
The safety stop limits the temperature range to 38 °C. The 38 °C
limit can be overridden by pressing the button (J1), see fig. [5].
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
Maintenance
For maintenance, see fold-out page II.
Inspect and clean all parts, replace if necessary and lubricate
with special valve grease.
Shut off the hot and cold water supply.
I. Non-return valve
1. With a 30mm open-ended spanner, unscrew and remove
mixer from unions.
2. Remove dirt strainer (L).
3. With a 12mm hexagon socket spanner, remove union
nipple (M) by turning clockwise (left-hand thread).
4. Remove non-return valve (N).
II. Thermoelement
1. Remove cap (H).
2. Unscrew and remove (I) and pull off temperature control
handle (J).
3. Unscrew and remove adjusting nut (A).
4. Pull off stop ring (B).
5. With a 24mm open-ended spanner, unscrew and remove
thermoelement (T).
Readjustment is necessary after every maintenance operation
on the thermoelement (see Adjusting).
III. Ceramic headpart
1. Pull off shut-off knob (O) and unscrew and remove
screw (P).
2. Remove snap insert (Q) and guide ring (R).
3. With a 17mm open-ended spanner, unscrew and remove
ceramic headpart (S).
Install in reverse order.
Replacement Parts, see fold-out page II ( * = special
accessories).
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Grohe 34364 Automatic 2000 compact bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Grohe 34364 Automatic 2000 compact in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Deens, Zweeds, Noors als bijlage per email.

De handleiding is 0,44 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info