590607
2
Verklein
Vergroot
Pagina terug
1/3
Pagina verder
Diodentest
Diode Testing
V / V
Gelijk- / mengspanningsmeting
Direct Voltage / Pulsating Voltage Measurement
V~/ Hz
Wisselspanning – Frequentie, zonder/met laagdoorlaatfilter
AC Voltage – Frequency, without/with Low-pass Filter
m
Capaciteit
Kabellengtemeting
Capacitance Cable Length Measurement
A / A
Gelijkstroom- / mengstroommeting
DC / Pulsating Current Measurement
A~ / Hz
Wisselstroom- / frequentiemeting
Alternating Current / Frequency Measurement
COM mA A
V
Temp
aEb
Doorstroomrichting
Sperrichting
0V !
0.654
0.L
... 5,1 V
+
0.443
V
!
DC
Meetbereik:
Measuring Range:
Conducting Direction
Reverse Direction
FUNC
ENTER
000.8
R
SL
COM mA A
V
Temp
aEb
– (+)
+ (–)
V= : 100 V 610 V
020.00
V
DC
AC
TRMS
020.00
V
DC
V
V
V
V
Meetbereiken:
> 15 V AC of/or > 25 V DC:
> 610 V:
Waarschuwingen voor gevaarlijke spanningen:
230
.
0
Caution! Dangerous Voltages:
Measuring Ranges:
max. 600 V (< 10 kHz)
!
P
max
= 6 x 10
6
V x Hz
FUNC
ENTER
V : 10 mV610 V
CLiP = OFF ! SETUP
COM mA A
V
Temp
aEb
max. 600 V (< 10 kHz)
V~: 10 mV 610 V
Hz: 1Hz 300 kHz
~
!
>610V:
0225.6
V
AC
TRMS
0049.9
Hz
AC
V~
Hz
V~
Hz
V~/Hz & Filter
P
max
= 6 x 10
6
V x Hz
V~ FilFilter actief / active
Hz FilFilter actief / active
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
CLiP = OFF ! SETUP
COM mA A
V
Tem p
aEb
10.38
F
0V !
!
+
+
10 pF ... 310 F
m
FUNC
ENTER
15.00
m
m
3.100 km/31.000 km
Meetbereiken:
Measuring Ranges:
COM mA A
V
Temp
aEb
k
Setup CAP
Kabeltype = constant !
!
Cable type = constant !
COM mA A
V
Tem p
aEb
~
R
x
~
R
x
1
3
2
Zekering
Fuse
FF 1,6 A / 700 V AC DC
6,3 mm x 32 mm
A
A
003.50
m A
DC
003.50
m A
DC
AC
TRMS
A
A
8
.
8
.
8
.
8
.
8
!
Stroom
Current
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
!
I > 1,1 A
A: 0,1 A . .. 1,1 A
A: 3 A . .. 1,1 A
COM mA A
V
Tem p
aEb
Stroom
Current
~
R
x
~
R
x
1
3
2
A~
Hz
A~
Hz
003.50
m A
AC
TRMS
0049.1
Hz
AC
8
.
8
.
8
.
8
.
8
!
Zekering
Fuse
FF 1,6 A / 700 V AC DC
6,3 mm x 32 mm
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
Hz: 1Hz
30 kHz
!
I > 1,1 A
A ~: 3 A . .. 1,1 A
A / Hz
Meting met stroomtang
Measurement with Current Transformer Clamp
M ISO @ 100 V / Hz
Isolatieweerstandsmeting
Insulation Resistance Measurement
Apparaat- en meetparameters SETUP
Device and Measuring Parameters
Technische gegevens – Technical Data
1)
bij / at 0 C...+40C
2)
als functie ZERO actief / with function ZERO active
3)
Vermogensbegrenzing /
Power limiting:
6 · 10
6
V · Hz (max. 600 V 1 kHz)
4)
voor maximale stroomwaarden, zie Stroommeetbereiken
max. current values see current measuring range
Elektrische veiligheid – Electrical Safety
Beschermingsklasse / Protection class II
– volgens /
per
IEC 61010-1:2010/EN 61010-1:2010/VDE 0411-1:2011
Meetcategorie / Measuring Category CAT I I / CAT III
Nominale spanning / Nominal Voltage 600 V / 300 V
Verontreinigingsgraad / Pollution degree 2
Testspa n ning / Te st Vol t age 3,5 kV~
– volgens / per IEC 61010-1/EN 61010-1
IP-classificering / Protection
– Behuizing / Housing: IP54 (drukcompensatie door
behuizing/pressure equalization
by means of the housing)
Tabellenuittreksel over de betekenis van de IP-code
Extract from table on the meaning of IP codes
Elektromagnetische compatibiliteit EMC
Electromagnetic Compatibility EMC
Storingsuitzending / Interference Emission
EN 61326-1:2006 Klasse B / class B
Storingsbestendigheid / Interference Immunity
EN 61326-1:
2006
EN 61326-2-1:
2006
Omgevingsomstandigheden – Ambient Conditions
Nauwkeurigheidsbereik / Accuracy range 0C ... + 40 C
Werktemperatuur / Operating temperature –10 C ... + 50 C
Opslagtemperatuur /
Storage temperature
zonder batterij / without battery – 25 C ... + 70 C
Relatieve luchtvochtigheid / relative humidity 40 ... 75 %
Geen condens toegestaan / no condensation allowed
Hoogte boven NAP tot / Elevation up to 2000 m maximum
Zekering – Fuse
FF(ultrarapid) 1,6 A / 700 V AC DC
6,3 mm x 32 mm
Uitschakelvermogen /
breaking capacity
: 50 kA (Min 10 kA)
Bij gebruik van een andere zekering vervalt de fabrieksgarantie.
If you use other fuses than the one indicated above you forfeit
your product guarantee.
Interne zekeringentest –
Internal Fuse Test
Zekering vervangen – Fuse Replacement
Koppel het apparaat van de meetkring af voordat u
het deksel van het zekeringenvakje openmaakt! Draai
daartoe de spleetschroef naar links. Deze kan niet ver-
loren gaan.Licht de zekering met de vlakke zijde van
het zekeringendeksel uit het vakje.
Als u het zekeringendeksel weer inzet, moet u de zijde met de
geleidehaken er het eerst inzetten.
Draai de spleetschroef naar rechts in.
Disconnect the instrument from the measuring circuit
before opening the fuse compartment lid! Turn the
(captive) slotted head screw counter-clockwise for
this purpose. Remove the fuse with the flat end of the
fuse compartment lid.
When refitting the fuse compartment lid the side with the guide
hooks must be inserted first. Then turn the slotted head srew
clockwise.
COM mA A
V
Te mp
aEb
* METRAFLEX
Overbren-
gingsverhou-
ding
Transforma-
tion ratio
CLIP
Meetbereiken
Measuring
Ranges
Tang
Current
sensor
300
mV
3 V 30 V
1:1
1mV/1mA
0,3 A
3 A 30 A
WZ12C
1:10
1mV/10mA 3 A 30 A 300 A
WZ12B
Z201A/B
METRAFLEX
1:100
1mV/100mA
30 A
300
A
3000 A
Z202A
/B
METRAFLEX
1:1000
1 mV/1 A
300
A
3000
A
(30kA)
WZ12C
Z202A/B
Z203A/B,*
~
R
x
0035
.
0
A
AC
TRMS
A~
Hz
1:1000
0050
.
1
Hz
AC
1:1000
SETUP
Stroom
Current
0035
.
0
A
1:1000
0035
.
0
A
1:1000
A
A
SETUP
DC
AC
TRMS
DC
TRMS
FUNC
ENTER
FUNC
ENTER
R
i
~ 9 M
R
i
V
V
V~
Hz
R
x
0V !
!
000.00
M
M
300 k/3 M/30 M/300 M
Meetbereiken:
Measuring Ranges:
a-b
a-E
b-E
M
ISO
@100V
COM mA A
V
Temp
aEb
ab
aE
Eb
ISO
a-b
FUNC
ENTER
UISO ON / OFF
ZERO
ESC
POL / UISO
FUNC
ENTER
UISO ON / OFF
a-E
FUNC
ENTER
UISO ON / OFF
ZERO
ESC
POL / UISO
FUNC
ENTER
UISO ON / OFF
b-E
FUNC
ENTER
UISO ON / OFF
ZERO
ESC
POL / UISO
FUNC
ENTER
UISO ON / OFF
short leads
00
.
00
voor de meting
before measurem.
a
a
b
b
E
E
UISO
bAtt: 2.92 V
verSion: 1.00
dAtE: 13.09.06
tiME: 11:15:19
OCCUP:
100.0%
... InFo
tEMP ...SEt
1nfo
Submenu's / Parameters / Sub-menus / Parameters
rAtE 0:05:00
0.diSP
0000.0/0.0
A.diSP
bArG/Point
CLiP
OFF/1:1...1000
APoFF
10...59min/on
U_ISo 100 V
CAP 10 ... 500nF
r_SL 100...3,1K
,
bEEP
01... 90
irStb ir on/oFF
Addr 01...15
dAtE 13.09.
tiME 11:15
C
F
Hoofdmenu's / Main Menus
opvragen instellen instellen
read set set
... SEnd ... StorE ...
bevestigen
confirm
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
MEASURE
SETUP
0
20
.
00
V
DC
AC
TRMS
Meetbereik
Measuring Range
Meetfout / Measuring Error
Overbelastbaarheid
1)
Overload capacity
/
300 mV
(
0,5% + 3 D)
2)
1,5% + 3 D
(> 300 D)
600 V
DC
AC
eff
Sinus/
sine
continu
continuous
3V
(
0,5% + 1 D)
1,5% + 3 D
(> 100 D)
30 V
300 V
600 V
1 Hz ... 300,00 kHz (0,5% + 1 D) 600 V
3)
max. 10 s
/
300 mA (0,5% + 5 D)
1,5% + 5 D
(> 100 D)
0,3 A
continu
continuous
3mA
(0,5% + 3 D)30 mA
300 mA
1A(0,5% + 5 D) 1,6 A 5 min
1 Hz ... 30,00 kHz (0,5% + 1 D)
4)
(... % v.d. meetw. + ... D)
300 0,5 + 3
2)
600 V
DC
AC
eff/rms
Sinus/
sine
max. 10 s
3k
0,5 + 1
30 k
300 k
3M
30 M 2 + 5
R
SL
300 3 + 5
R
SL
3k 3 + 5
300 3 + 5
5,100 V 2 + 5
30 nF (1 % + 6 D)
2)
600 V
DC
AC
eff
Sinus/
sine
max. 10 s
300 nF
(1% + 6 D)3 F
30 F
300 F (5% + 6 D)
IP XY
(1e cijfer X)
(1
st
digit X)
Bescherming tegen
binnendringen van vaste
vreemde deeltjes
Protection against
foreign object entry
IP XY
(2e cijfer Y)
(2
nd
digit Y)
Bescherming tegen bin-
nendringen van water
Protection against the
penetration of water
5
Stofvrij
dust protected
4
Spatwater
splashing water
Zekering defect
0fuse
A
DC
Fuse defective
?
Zekering testen
Test Fuse
A
A
A~
Hz
!
!
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gossen Metrawatt METRAHIT T-COM bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gossen Metrawatt METRAHIT T-COM in de taal/talen: Nederlands als bijlage per email.

De handleiding is 0,6 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Gossen Metrawatt METRAHIT T-COM

Gossen Metrawatt METRAHIT T-COM Gebruiksaanwijzing - Nederlands - 72 pagina's

Gossen Metrawatt METRAHIT T-COM Snelstart handleiding - Deutsch, English - 2 pagina's

Gossen Metrawatt METRAHIT T-COM Gebruiksaanwijzing - English - 72 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info