11109876
5432
MEMORY
Recalling the Memory
This thermometer stores 25 most recent read-
ings
Be sure the thermometer
is OFF before recalling this
memory.
Press to enter the mem-
ory mode.
Each time you press the
Memory Button, a result will
be displayed in the order of
dates (latest result shown
rst), together with “MEM”
and number (from 1 to 25).
LED in green or red will ap-
pear according to the mem-
ory reading.
When the memory is full, the
oldest result is deleted as
the new one added. When
the last record displayed in
the display, press Memory
Button again to return the
rst record.
Exit the memory.
Press ON/OFF Button to exit
the memory or keep the me-
ter in idle for 30 seconds to
switch off automatically.
Clear the memory
Delete the record by unplug-
ging the battery and power
off.
The thermometer will automatically turn off if
left idle for 30 seconds.
As an Object Measurement Thermometer
Press “ON/OFF” Switch to turn
on the thermometer rst.
Push the Mode switch to select
Object mode.
The temperature unit ashes.
Move the probe close to the ob-
ject and take measurements.
Make sure the probe is at and
close to the object, not at an an-
gle. Perform a measurement with
a distance within 3 cm. When
ready, push measurement button
to take measurements.
Read the result.
The measurement result will be
done in 1 second. The reading is
shown together with LED lighting
and one long beep informs about
the temperature measurement,
and after a while another short
beep, conrming the saving of
the result to the memory and
readiness for the next measure-
ment.
Press the “ON/OFF” button to turn off the unit,
or leave it idle for 30 seconds, the unit will switch
off automatically.
Move the probe close to the
forehead and take measure-
ments
Make sure the probe is at and
close to the forehead, not at
an angle. Perform a forehead
measurement with a distance
within 3 cm.
Read the result.
The measurement result will be
done in 1 second. The reading
is shown together with LED
lighting and one long beep in-
forms about the temperature
measurement, and after a while
another short beep, conrming
the saving of the result to the
memory and readiness for the
next measurement.
Press the “ON/OFF” button to turn off the unit,
or leave it idle for 30 seconds the unit will switch
off automatically.
NOTE:
As the forehead measurement temperature
is likely to be affected by sweat, oil and the
surroundings, the reading shall be taken as a
reference only.
If the probe is placed at an angle close to the
forehead measurement, the reading will be
affected by surrounding temperature. Babies’
skin reacts very quickly to the ambient temper-
ature. Therefore, do not take their temperature
with the A200 Infrared thermometer during or
after breastfeeding, because the skin temper-
ature may then be lower than the internal body
temperature.
If the measured temperature is < 32°C (89.6°F),
the display will show with LO symbol.
If the reading is≥ 37.8°C (100.04°F) and <
42.9°C (109.22°F), the display will show to-
gether with red LED and six short beeps.
vary from one individual/person to next. It also
varies by location on the body and time of day.
Below shows the statistical normal ranges from
different sites. Please keep in mind that temper-
atures measured from different sites, even at the
same time, should not be directly compared. Fe-
ver indicates that the body temperature is higher
than normal. This symptom may be caused by
infection, overdressing or immunization. Some
people may not experience fever even when they
are ill. These include, but are not limited to, in-
fants younger than 3 months old, persons with
compromised immune systems, persons taking
antibiotics, steroids or antipyretics (aspirin, ibu-
profen, acetaminophen), or persons with certain
chronic illnesses. Please consult your physician
when you feel ill even if you do not have fever.
Table*1 Normal Temperature Range of various
body sites
Oral 0.6°C (1°F) or more above or be-
low 37°C (98.6°F)
Rectal/ear 0.3°C to 0.6°C (0.5°F to 1°F)
higher than oral temperature
Axillary
(armpit)
0.3°C to 0.6°C (0.5°F to 1°F) low-
er than oral temperature
PERFORM THE TEST
As a Body Measurement Thermometer
Press “ON/OFF” Button to turn
on the thermometer rst.
Push the Mode switch to select
Body mode.
The temperature unit ashes.
1. Remove the battery cover as
the arrow direction accord-
ingly.
2. Remove the old batteries
and replace with two 1.5V
AAA size alkaline batteries.
Taking care to match the
Positive ( + ) and Negative
( - ) indications
3. Close the battery cover as
the arrow direction accord-
ingly.
NOTE:
1. Although the thermometer works when “ ”,
appearing, we still recommend that you
change the batteries to obtain an accurate re-
sult.
2. Remove the batteries if stored for a long period
of time.
3. The batteries should be kept away out of chil-
dren’s reach.
If they are swallowed, promptly see a doctor
for help.
DETAILED INFORMATION
About Normal Body Temperature & Fever
The temperature in the forehead and temple area
differs from the internal temperature, which is
taken orally or rectally. Vasoconstriction, an ef-
fect which constricts the blood vessels and cools
the skin, can occur during the early stages of a
fever. In this case, the temperature measured by
the A200 Infrared thermometer may be unusu-
ally low. If the measurement therefore does not
match the patient’s own perception or is unusu-
ally low, repeat the measurement every 15 min-
utes. As a reference, you can also measure the
internal body temperature using a conventional
oral or rectal thermometer. Body temperature can
Long-press the Measure-
ment Button for 5 seconds
until the signal -- °C or °F
displayed on the LCD panel
as gure shown. Re-press
the Measurement Button to
select °C or °F unit.
Turn ON/OFF the Led Light
This meter provides Led Light to help users
placing the thermometer at the correct posi-
tion.
Be sure the thermometer is
OFF before turn ON/OFF the
Led Light.
1.
Long-press the Measure-
ment Button for seconds
until Signal -- °C or °F dis-
played on the LCD panel.
2 Release the measurement
button, then short-press
the ON/OFF Button, the
signal -- Led or OFF will
displayed on the LCD pan-
el as gure shown.
3 Quick press the measure-
ment button, and select
Led or OFF to turn ON/OFF
the Led Light
.
Replacing the Battery
The meter will display “ ” to alert you when
the meter power is getting low, please follow
the steps below to replace new batteries im-
mediately.
Display Screen
1. Body mode indication
2. Object mode indication
3. Memory indication
4. Temperature reading
5. Temperature unit
6. Battery indication
Display Mode
Two modes can be selected.
1.Body Mode
This mode is used to
measure the forehead
temperature.
2.Object Mode
This mode is used to
measure the object tem-
perature.
Select the Temperature Unit
This meter provides two measurement units
used for indicating the body/object tempera-
ture, °C or °F, for your preferred selection.
Be sure the thermometer
is OFF before selecting the
temperature unit.
How does it work
The thermometer measures the infrared heat
generated by the surface of the skin over the ves-
sel and its surrounding tissue. The thermometer
then converts it into a temperature value.
NOTE:
The thermometer does not emit any infrared en-
ergy.
Highlighted Features
Measurement that does not require probe cov-
er, thereby saving cost of replacement.
Automatically power off if left idle for 30 sec-
onds.
Memory function allows you to recall previous
results up to 25 previous results.
Easy to read LCD with green backlight in a dark
environment.
Color visible of fever (red) and measurement in
progress (green).
Meter Overview
1. nfrared Sensor
2. Led Light
3. Display Screen
4. Measurement /
Memory Button
5. ON/OFF Button
6. Mode Switch
7. Battery Cover
instructions to assist to SERVICE PERSONNEL
in parts repair.
Do not clean or maintenance the device is in
use.
Avoid direct sunlight.
Avoid dropping the thermometer, if it happens
and you think the thermometer may be dam-
aged, please contact customer services imme-
diately.
Do not touch the lens.
Do not disassemble the thermometer.
Basic safety precautions should always be
observed, especially when the thermometer is
used on or near children and disabled persons.
This thermometer is not intended to substitute
for a consultation with your physician.
This thermometer and the subject must remain
in a stable environment for at least 30 minutes
before measuring the temperature.
When the measured temperature falls with-
in the fever temperature range of ≥37.8°C
(100.04°F) and <42.9°C (109.22°F), as indicat-
ed by the red LED on display, please consult
with your physician immediately.
Restrictions of Use
This thermometer is clinically proven to produce
accurate temperature measurements. However,
please be advised that the accuracy can not
be ensured when the thermometer is not clean.
Check that the probe is clean before taking a
measurement.
Intended Use
A200 Infrared Thermometer is intended for the
intermittent measurement and monitoring of hu-
man body temperature from forehead measure-
ment at home, clinics and hospital.
A control measurement using a conventional
thermometer is recommended in the following
cases:
1. If the reading is surprisingly low.
2. For new-born infants, up to 100 days old.
3. For children under three years of age who have
a weakened immune system or who react unu-
sually in the presence or absence of fever.
MEMORY ......................................................... 11
Recalling the Memory ...................................... 11
Clear the memory ............................................ 11
MAINTENANCE ............................................... 12
Care & Cleaning ............................................... 12
FAULT INDICATION ......................................... 12
SYMBOL INFORMATION ................................ 13
SPECIFICATIONS ............................................ 14
DISPOSAL OF DEVICE .................................... 15
REFERENCE OF STANDARDS ........................ 15
Device Standards: ........................................... 15
Classication: .................................................. 15
Electromagnetic Compatibility: ....................... 15
WARRANTY ..................................................... 17
MANUFACTURER’S DECLARATION
OF THE EMC ................................................... 21
BEFORE YOU BEGIN
Cautions and Warnings
As with any thermometer, proper technique is
crucial to obtaining accurate temperature read-
ings. Please read this manual thoroughly and
carefully before using.
Always operate the thermometer in an operat-
ing temperature range 10°C to 40°C (50°F to
104°F), and relative humidity15 to 95%.
Always store the thermometer in a cool and dry
place -25°C to 55°C (-13°F to 131°F) and rela-
tive humidity 15% to 95%.
The device requires no calibration. The product
has been calibrated before the factory inspec-
tion.
The device contains no user serviceable parts.
The user must check that the equipment func-
tions safely and see that it is in proper working
condition before being use
• The manufacturer does not require such pre-
ventive inspections by other persons.
No modication of this equipment is allowed.
The device is not suitable for use in the pres-
ence of ammable anesthetic mixtures with air
or with oxygen or nitrous oxide.
Manufacturer will provide circuit diagrams,
component part lists, descriptions, calibration
System Owner
Thank you for purchasing the A200 Infrared Ther-
mometer. Please read this instruction manual
first, so you can use this thermometer safely and
correctly. Please keep this instruction manual for
future reference. This innovative medical device
uses advanced infrared (IR) technology to meas-
ure temperature instantly and accurately on the
forehead or object.
IMPORTANT SAFETY INSTRUCTIONS
READ BEFORE USE
The following basic safety precautions should
always be taken.
1. Close supervision is necessary when the ther-
mometer is used by, on, or near children, hand-
icapped persons or invalids.
2. Use the thermometer only for the intended use
described in this manual.
3. Do not use the thermometer if it is not working
properly, or if it has suffered any damage.
KEEP THESE INSTRUCTIONS AT A SAFE
PLACE
CONTENTS
BEFORE YOU BEGIN ........................................ 2
Cautions and Warnings ..................................... 2
Restrictions of Use ............................................ 3
Intended Use ..................................................... 3
How does it work .............................................. 4
Highlighted Features ......................................... 4
Meter Overview ................................................. 4
Display Screen................................................... 5
Display Mode..................................................... 5
Select the Temperature Unit .............................. 5
Turn ON/OFF the Led Light ............................... 6
Replacing the Battery ........................................ 6
DETAILED INFORMATION ................................. 7
About Normal Body Temperature & Fever......... 7
PERFORM THE TEST ........................................ 8
As a Body Measurement Thermometer ............ 8
As an Object Measurement Thermometer ...... 10
A200 INFRARED
NON CONTACT
THERMOMETER
Please note:
This medical instrument must be used
according To instructions to ensure
accurate readings.
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
PROFESSIONAL MEDICAL PRODUCTS
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gima A200 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gima A200 in de taal/talen: Engels als bijlage per email.

De handleiding is 0.42 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info