INTRODUCTION
GEMINI 7350.
The system 7350 is a self-powered compact alarm unit that includes sensors and siren. It's suitable to be
fitted on vehicles equipped with 12 Volts battery (negative ground).
DESCRIPTION
- Remote controlled compact alarm unit with self-powered electronic siren and dynamic code transmission
(433.92MHz).
- Direction lights outputs.
- Additional siren negative output.
- Universal central door locking control, electric windows and sunroof control on vehicles equipped with
"Comfort Closing System".
- Doors, boot and bonnet protection.
- External sensors input (Volumetric protection).
- Engine immobilisation (Not available for Belgium model - V.V.3 rules).
- Alarm passive arming with casual re-arming feature and "GARAGE" position.
- LED alarms memory.
- Arming vehicle check.
- Diagnostic Mode feature (for the installer).
- Remote controlled "PANIC" alarm / "ELECTRIC BOOT" release. (Selectable).
The alarm system is equipped with two codified remote transmitter and two codified electronic keys.
FITTING INSTRUCTIONS (reserved to the installer).
- The alarm unit must be installed in the bonnet in vertical position, with the connectors turned upwards, in a
place far from heat sources, water ingress, ignition control unit and coils.
- Be sure that the alarm wiring harness is far from high-tension wires of the original vehicle plant in order to
avoid interference which could generate a wrong functioning.
- On vehicles equipped with catalytic muffler the engine immobilisation must be carried out on fuel pump.
- If the alarm system is equipped with a ultrasonic module (ref. 5123), the ultrasonic cells must be fitted at
the top of each windscreen pillar, far from the ventilation or air-conditioning outputs and pointed at each
opposite diagonal corner.
- Connect the positive power supply of the alarm unit to the positive pole of the vehicle battery and connect
the negative power supply of the alarm unit to the negative pole of the battery or to the vehicle frame.
- IMPORTANT : In order to obtain the properly working of the passive arming / door protection it's
mandatory to connect the GREEN-BROWN wire to the door pin switches.
DIP SWITCHES PROGRAMMING TABLE
1 ON Panic alarm ON / Boot release OFF
1 OFF Panic alarm OFF / Boot release ON
2 ON Central Door Locking Pulse 6"
2 OFF Central Door Locking Pulse 0,5"
3 ON Central Door Locking Comfort Pulse ON ( 25" )
3 OFF Central Door Locking Comfort Pulse OFF
4 ON Alarm Passive Arming ( with casual re-arming ) ON *
4 OFF Alarm Passive Arming OFF *
5 ON Diagnostic Mode ON
5 OFF Diagnostic Mode OFF ( Normal Mode )
6 ON Remote Controls / Electronic Keys self-learning ON
6 OFF Remote Controls / Electronic Keys self-learning OFF ( Normal Mode )
IMPORTANT : THE DIP-SWITCHES MUST BE SELECTED BEFORE TO CONNECT THE POWER
SUPPLY TO THE ALARM UNIT. ( SEE ALSO "DIP-SWITCHES RE-SETTING" CHAPTER).
* For the Belgium market unit it's no possible to switch OFF the Alarm Passive Arming feature ( V.V.3 Rules ).
DIP-SWITCHES RE-SETTING.
It's possible to change the dip-switch settings, after the power supply connection , by the following instructions :
1. Disarm the alarm unit by a remote control / electronic key.
2. Set the dip-switches in order to program the features required.
3. Turn the ignition switch to ON position ( without start the vehicle engine !! ).
4. Insert , for more than 3 seconds, an electronic key in the LED / Socket . To confirm the new dip-switch settings a LED
flash /audible tone will be emitted.
5. Turn the ignition switch to OFF position.
DIAGNOSTIC MODE ( final check for the installer or quick check during after sale service ).
This feature allows to the installer / service personnel to quickly verify the correct working of the alarm unit and the
electrical connections to the vehicle plant.
DIAGNOSTIC SET-ON.
To enter in the Diagnostic Mode it's possible to follow two different ways :
1. During the installation of the alarm system : Set on the dip-switch no. 5 before to connect the power supply of the alarm
unit and then connect the power supply.
2. For post-installation services : Set on the dip-switch no. 5 following the instructions described in the "DIP-SWITCHES
RE-SETTING" chapter.
To confirm the diagnostic mode will be emitted four indicator lights flashes / audible tones. At the end of the signalling the
LED and the external module output ( +A / PINK wire) will be switched on.
In this condition it's possible to test each alarm input, and if the external connection and/or the internal alarm unit circuit
works properly an audible tone / indicator lights flash will be emitted each time the input of the alarm system will be
triggered. It's important to have a delay time of 1 second ( or more ) between each alarm input triggering.
In the diagnostic mode it's possible to verify the right working / transmission range of the remote controls by pressing the
push button no.1 of the handsets. If the device works properly an audible tone / indicator lights flash will be emitted.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gemini 7350 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gemini 7350 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,89 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info