GEMINI 1160RSD
Gemini 1160RSD is a remote control unit. Supplied with two coded transmitters it
has the ability to operate central locking, as well as offering panic switch, passive
arming and outlets for control sirens, vehicle's own horns and hazard lights.
It offers the following protections
:
- the passenger compartment by pin switches and also voltage drop sensor.
- engine immobilisation obtained by the interruption of an electric circuit that
controls the engine.
It has also the following abilities
:
- it controls all types of sirens or vehicle horns which are positive or negatively
switched.
- it can be connected to volumetric, vibration and anti-lifting sensors.
- it can be interfaced with automatic windows or roof closing units.
OPERATION
: (For End User)
Pushing the BLACK button on the hand held transmitter will switch on the alarm
and operate the central locking.
The receiver is mounted inside the passenger compartment. The arming signal is
acknowledged by a single 3-seconds pulse on the hazard lights circuit.
Pushing the RED button on the hand held transmitter twice will switch the alarm
on with the Remote Sensor Disconnection (for example ultrasonic sensor). In
this case the alarm connection is acknowledged bu two pulses of the direction
indicator lights.
In both cases at the same time the engine immobilisation circuit will be activated.
There are different exit delay periods for each type of activation (see Table A)
before the alarm becomes armed.
After the arming periods have elapsed, any attempt to enter the vehicle will
instantly trigger the alarm. The siren will sound and the hazard lights will also
flash. This will continue for a period of 30 seconds and then the unit will switch off
and automatically re-set after a further 10 seconds. In case of continuous
triggering, the alarm condition will occur as shown in Table A.
The alarm can be de-activated at any time by operating the BLACK button of the
transmitter. The hazard lights will signal 3 off 1 second pulses if no alarm
conditions have occurred. If the alarm has been triggered, the hazard lights will
signal 5 off 1 second pulses (alarm has memory of an atempted "break-in").
If the passive arming has been activated, the alarm unit will arm itself after 15
seconds from the engine stopping and the last door or bonnet/boot/tailgate
closing, also the arming visual signal will operate. To obtain the central locking
closing, you must push the BLACK transmitter button within 20 seconds.
When the system is armed you can activate the panic alarm by
pressing the RED transmitter button. The siren and the hazard lights circuit will be
activated for 10 seconds. The emergency de-activator can be either a key switch
or a toggle switch. If a GEMINI 5025 electronic self-powered siren is used, its key
switch must be turned OFF to obtain the emergency alarm de-activation (it acts as
an over-ride switch).
TABLE A
EXIT DELAY TIME ENTRY SENSOR NO. OF ALARM
CYCLES
40 sec. Door pin switches 3
5 sec. Bonnet/boot/tailgate switches 3
5 sec. Ignition line unlimited
40 sec.
Volumetric, vibration and anti-
lifting sensors
3
40 sec. Voltage drop sensor unlimited
PRE-INSTALLATION CHECKS
: (For the Installer)
- Disconnect the negative terminal of the battery and only re- connect after the
installation is complete.
- Remove the cover from the rear of the unit, these allow access to the SW2-
SW3. SW1 is located next to the connectors.
Arrange the central unit as follows:
a. SW1 in position A. Voltage drop sensor activated.
SW1 in position B. Voltage drop sensor isolated.
This sensor must be isolated if on the vehicle there are loads that can operate
once the ignition has been switched off (i.e. cooling fan).
b. SW2 in position A o B as shown in central locking diagrams.
c. SW3 in position A. Continous signal.
SW3 in position B. Intermittent signal. For connecting vehicle's own horn select
position B (intermittent signal).
d. To de-activate the passive arming function, cut the YELLOW- GREEN wire
loop.
WIRING INSTRUCTIONS
-
Check that all wires of the harnesses are fitted in the correct positions on
the connectors (checking against alarm wiring diagrams).
1.
POSITIVE
POWER FEED
.
With the voltage drop sensor activated, the
RED wire must be connected to the interior light circuit at the fuse box.
If the voltage sensing is de-activated, the RED wire
CAN
be connected
to the main fuse box feed or directly to the positive terminal of the
battery. If a self-powered electronic siren (GEMINI 5025) is used the
RED wire of the remote unit must be connected to the RED wire of the
siren.
DO NOT CONNECT THE RED WIRE OF THE SIREN TO
POSITIVE.
Use the 15 Amp fuse supplied in the kit.
2.
NEGATIVE POWER FEED.
Connect the BROWN wire to a stable body
earth. If possible use existing body earth points or battery negative
terminal.
3.
IGNITION LIVE.
Connect the YELLOW wire to a positive ignition feed.
This wire
must be fed also whilst starting the engine
.
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gemini 1160RSD bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gemini 1160RSD in de taal/talen: Engels als bijlage per email.

De handleiding is 0,13 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info