The warm extract air must be emitted from the room via the air hose. This can be executed e.g. via a tilted
window, a door or wall aperture. Make sure that no warm outside air can enter the room. For effective
cooling, we recommend our selection of various accessories which reduce or prevent entry of warm air into
the room.
Place the function to COOLING. Set the target temperature using the temperature control. The settable
temperature range is between 17 and 30 degrees target temperature. The unit must only be used in an
ambient temperature of maximum 32°C.
Note: After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for three
minutes. Cooling effect may require a further 10 minutes. Further information is available under the item, Troubleshooting.
COOLING IN OUTDOOR OPERATION
The unit is outside the room to be cooled.
Connect the air hose and the air outlet grid to the unit as displayed in the illustration; the air hose
connection piece and air outlet grid need to be exchanged.
Place the unit in the shade if possible and in a cool place in order to increase efficiency and to avoid
overheating. At an ambient temperature of over 32 degrees, the unit may deactivate. If this occurs
continuously, we recommend you temporarily use the INDOOR OPERATION of the unit. We recommend
that a drainage hose for condensation water be connected.
Set the function to COOLING. The settable temperature range is between 17 and 30 degrees. This can be
set using the temperature control.
The air with high oxygen content cooled by the unit is fed into the room via the air hose. This can be
executed e.g. via a tilted window, a door or wall aperture. Make sure that no warm outside air can enter the
room. For effective cooling, we recommend our selection of various accessories which reduce or prevent
entry of warm air into the room, or via the remote control.
Using the various Comfort Control Kits you can also control the unit from inside using the remote control.
After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for three minutes.
Cooling effect may require a further 10 minutes. Further information is available under the item, Troubleshooting.
HEATING
On cold days it is recommendable to start the unit early in order to avoid intensive cooling of the room.
For the heating function and to improve the heating effect and avoid lower temperatures (lower than 17°C)
we recommend you remove the rubber plug from the condensation water outlet and allow the
condensatation water to leak out of the unit using the drainage hose. However, the drainage hose does not
have to be connected in the heating mode, Please make sure that the condesnation water outlet is closed
with the rubber cap during operation. In such a case, proceed analogously to the emptying of the water tank
in the cooling function.
The heating function of the unit must not be operated at a room temperature of more than 23°C or less than
7°C. The unit can also be operated with heating function, if the outside temperature is lower than 7°C.
However, you must then ensure that the unit is operated inside and the room temperature is at least 7°C.
Caution: In the heating mode, separate setting of the ventilator is not provided, since the highest
ventilation level is already preset to avoid overheating of the unit.
Heruntergeladen von manualslib.de Handbücher-Suchmachiene
17

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Fral FSC09 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Fral FSC09 in de taal/talen: Duits, Engels als bijlage per email.

De handleiding is 7,74 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info