741420
1
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
LBT80945 DS80IM35-001E
DT15
MADE IN ITALY
1
2
3
Tavola dei paesi in cui le frequenze del
prodotto sono limitate o non ammesse -
Countries in which the product frequencies are
restricted or not allowed - Tableau des pays
dans lesquels les fréquences du produit sont
limitées ou ne pas admises
Elkron è un marchio commerciale di Urmet
S.p.A.
Elkron is a trademark of Urmet S.p.A.
Elkron est une marque commerciale de Urmet
S.p.A.
Via Bologna, 188/C – 10154 Torino (TO) Italy
Tel.+39.0113986711 Fax+39.0113986703
www.elkron.cominfo@elkron.com
CARATTERISTICHE TECNICHE
Tensione nominale di alimentazione: ........ 12V +/- 3V
Assorbimento a 12 V : ............................ 8mA nom. 22mA max
Sensibilità Microonda (MW): ..................... 0,5÷15m±20% (con trimmer)
Frequenza: ................................................ 10,525 GHz
Potenza di emissione (EIRP): .................... 8dBm
Portata: ...................................................... 15 m
Copertura MW: .......................................... 90° orizzontale - 36° verticale
Copertura IR: ............................................. 90°
Zone sensibili: ........................................... 18 su 4 piani con creep zone
Opto Relè di allarme: ................................. 100mA / 24V
Tamper antimanomissione: ....................... 100 mA / 30V
Tempo Allarme: ........................................ 3 sec
Temperatura di funzionamento: ................. -10°C ÷ +55°C
Umidita Ambientale:................................... 95%
MTBF Teorico: ........................................... 120.000 ORE
Dimensioni (h x l x p): ................................ 107x61,5x43,5 mm
Peso: ......................................................... 110 g
Livello Prestazione: ................................... EN50131-2-4. Grado 2, CLASSE II
ACCESSORI OPZIONALI
Snodi per IR15 - DT15 - DT15AM (10 pezzi) ref. 80SP1E00113 / ref.
80SP1F00113
AVVERTENZE
Installare il sensore su superfici rigide, prive di vibrazioni, ad una altezza
compresa tra 2 e 2,3 metri facendo riferimento ai diagrammi di rilevazione in
modo tale che il sensore rilevi spostamenti trasversali nella zona protetta.
Evitare il posizionamento del sensore vicino a fonti di calore o alla luce diretta
del sole.
Evitare la riflessione dell’energia elettromagnetica su ampie superfici quali ad
esempio specchi, pareti metalliche etc.
Evitare di puntare il sensore su lampade fluorescenti o comunque di porlo nelle
immediate vicinanze delle stesse.
Evitare che esistano, a causa di mobili, scaffalature, etc. zone cieche nell’area
protetta entro cui possa muoversi l’intruso. Evitare la presenza di animali
nell’area protetta.
Nel caso di installazioni ad altezze superiori ai 2,1 metri si consiglia l’utilizzo
dello snodo opzionale, inclinando il sensore in modo da adattare al meglio i
campi di copertura alle effettive necessità.
INSTALLAZIONE SENZA SNODO
Per rimuovere il coperchio del sensore togliere la vite di chiusura (se inserita) e
premere con un cacciavite sul dente di fissaggio, verso l’interno della feritoia.
Per togliere il circuito stampato allargare uno dei ganci E1-E2 (Fig. 2).
Attenzione: non toccare con le dita il sensore piroelettrico.
Fondo plastico del sensore (Fig. 2):
F1-F4 = PREDISPOSIZIONI PER IL FISSAGGIO AD ANGOLO
A-B = PREDISPOSIZIONI PER IL FISSAGGIO SU SUPERFICIE PIANA
C-D = PREDISPOSIZIONI PER IL PASSAGGIO CAVI
Fissare il fondo plastico alla parete con le viti e i tasselli, avendo cura che le teste
delle stesse non tocchino la scheda elettronica. Rimontare il circuito sul fondo
plastico.
INSTALLAZIONE CON SNODO
I manuali completi degli snodi sono disponibili sul sito www.elkron.com.
DESCRIZIONE MORSETTIERA
I Ingresso Inhibit
- + Alimentazione 12V
NC TAMP Contatto N.C.
NC ALL Contatto N.C. del relè di allarme
PRIMA ALIMENTAZIONE
Fornita l’alimentazione, il sensore entra nella fase di inizializzazione, durante la
quale i 3 LED lampeggiano alternativamente. Dopo questa fase (che dura 60
secondi circa), il sensore diventa operativo.
In questa modalità, indipendentemente dallo stato del Jumper di LED OFF, il
sensore visualizzerà le rilevazioni della Microonda, quelle dell’Infrarosso e lo
stato di Allarme per permettere all’Installatore di verificarne il funzionamento.
Questa condizione permane per 20 minuti.
Trascorso questo tempo il Sensore visualizzerà:
se in Led ON ( Jumper inserito) solo gli Allarmi tramite il led Blu;
se in Led OFF (Jumper NON inserito) solo eventuali memorie.
Procedere con il walk test in questo modo:
MW (Microonda)
Regolare il trimmer (portata 0,5 - 15 mt) in funzione dell’ambiente da proteggere,
verificando le rilevazioni di MW tramite il LED VERDE.
Nota: la portata della MW va regolata al minimo necessario poiché, essendo le
Microonde in grado di oltrepassare i muri, possono rilevare disturbi e movimenti
all’esterno del locale da proteggere.
INFRAROSSO (PIR)
Applicare il frontale plastico e, a LED spenti, muoversi nell’area di pertinenza del
sensore verificando la rilevazione del PIR tramite il LED GIALLO.
FUNZIONI
AUTOMATIC ECO
Il sensore è equipaggiato con uno speciale algoritmo che riduce al minimo le
emissioni della Microonda.
Senza necessariamente collegare l’ingresso di Inhibit, il sensore, tramite il
monitoraggio dei movimenti nell’ambiente, determina se l’impianto è inserito o
disinserito.
Questa cognizione gli permette di limitare al massimo le emissioni di Microonda
ad impianto disinserito e quindi di non irradiare inutilmente le persone presenti
nell’ambiente.
Si ottiene questo vantaggio pur senza avere nessuna perdita di sensibilità di
rilevazione, né di immunità ai falsi allarmi.
LED OFF - Jumper Disinserito (di fabbrica inserito)
Disattiva le visualizzazioni di rilevazione, mantenendo abilitate le visualizzazioni
relative alle memorie.
FUNZIONI CON INGRESSO INHIBIT
Queste funzioni vengono attivate/disattivate tramite inserimento/disinserimento
dell’impianto. A tale proposito viene considerato:
12V sull’ingresso INHIBIT = impianto disinserito
0V sull’ ingresso INHIBIT = impianto inserito
ABILITAZIONE REMOTA LED - CONDIZIONE RICHIESTA LED OFF
Al disinserimento dell’impianto, il sensore si predispone alla riabilitazione delle
visualizzazioni di rilevazione. Le visualizzazioni verranno riabilitate alla prima
rilevazione effettuata e rimarranno attive per 30sec.
MEMORIE
Al disinserimento dell’impianto, verrà visualizzata la memoria del primo allarme
avvenuto, come in TAB.1 (VISUALIZZAZIONI IN STATO DI MEMORIA). La
memoria verrà resettata al successivo inserimento dell’impianto.
RITARDO della MEMORIA per utilizzo in INGRESSI TEMPORIZZATI
Tempo di uscita: gli allarmi che si verificano entro i primi 30dall’inserimento
dell’impianto vengono cancellati.
Tempo di ingresso: gli allarmi che si verificano 30” prima del disinserimento
dell’impianto vengono cancellati.
DICHIARAZIONE DI CONFORMITÀ UE SEMPLIFICATA
Il fabbricante, URMET S.p.A., dichiara che il tipo di apparecchiatura radio:
RIVELATORE A DOPPIA TECNOLOGIA DT15 è conforme alla direttiva
2014/53/UE. Il testo completo della dichiarazione di conformità UE è disponibile
al seguente indirizzo Internet: www.elkron.com.
DIRETTIVA 2012/19/UE DEL PARLAMENTO EUROPEO E DEL
CONSIGLIO del 4 luglio 2012 sui rifiuti di apparecchiature elettriche
ed elettroniche (RAEE).
Il simbolo del cassonetto barrato riportato sull’apparecchiatura o sulla sua
confezione indica che il prodotto alla fine della propria vita utile deve essere
raccolto separatamente dagli altri rifiuti. L’utente dovrà, pertanto, conferire
l’apparecchiatura giunta a fine vita agli idonei centri comunali di raccolta
differenziata dei rifiuti elettrotecnici ed elettronici. In alternativa alla gestione
autonoma è possibile consegnare l’apparecchiatura che si desidera smaltire al
rivenditore, al momento dell’acquisto di una nuova apparecchiatura di tipo
equivalente. Presso i rivenditori di prodotti elettronici con superficie di vendita di
almeno 400 m2 è inoltre possibile consegnare gratuitamente, senza obbligo di
acquisto, i prodotti elettronici da smaltire con dimensione massima inferiore a 25
cm. L’adeguata raccolta differenziata per l’avvio successivo dell’apparecchiatura
dismessa al riciclaggio, al trattamento e allo smaltimento ambientalmente
compatibile contribuisce ad evitare possibili effetti negativi sull’ambiente e sulla
salute e favorisce il reimpiego e/o riciclo dei materiali di cui è composta
l’apparecchiatura
.
TECHNICAL SPECIFICATIONS
Nominal power voltage: ............................. 12V +/- 3V
Consumption at 12 V :
.......................... 8mA nom.
22mA max.
Microwave sensitivity (MW):
.................... 0,5÷15m±20% (with trimmer)
Frequency: ................................................ 10.525 GHz
Emission power (EIRP): ............................ 8dBm
Range: ....................................................... 15 m
MW coverage: ........................................... 90° horizontal - 36° vertical
IR coverage: .............................................. 90°
Sensitive zones:
...................................... 18 on 4 floors with creep zone
Alarm relay opto: ....................................... 100mA / 24V
Tamperproof switch: .................................. 100 mA / 30V
Alarm time:
.............................................. 3 sec
Working temperature range: ...................... -10°C – +55°C
Ambient humidity: ...................................... 95%
Theoretical MTBF: ..................................... 120,000 HOURS
Dimensions (h x w x d): ............................. 107x61.5x43.5 mm
Weight: ...................................................... 110 g
Performance level: .................................... EN50131-2-4. Degree 2, CLASS II
OPTIONAL ACCESSORIES
Brackets for IR15 - DT15 - DT15AM (10 pcs) Ref.
80SP1E00113 / Ref.
80SP1F00113
CAUTIONS
Install the sensor on rigid, vibration-free surfaces at a height comprised
between 2 and 2.3 metres making reference to the detection diagrams so that
the sensor can detect movements crossing the protected zone and the
microwave module can detect approaching movements.
Avoid positioning the
sensor close to sources of heat or direct sunlight.
Avoid the reflection of electromagnetic energy on large surfaces, such as
mirrors, metal walls etc.
Avoid pointing the sensor towards, or in all cases placing it near, fluorescent
lights.
Avoid the creation of blind areas caused by furniture, shelving etc. in the
protected area in which an intruder could move about.
Avoid the presence of
animals in the protected area.
In case of installations at heights greater than 2.1 metres, it is advisable to use
the optional bracket, including the sensor so as to adapt the coverage fields
better to the actual needs.
INSTALLATION WITHOUT BRACKET
To remove the sensor cover, remove the fastening screw (if inserted) and press
with a screwdriver on the fastening screw towards the inside of the slot.
Widen one of the hooks E1-E2 to remove the printed circuit (Fig. 2).
Warning:
do not touch the pyroelectric sensor with your fingers.
Plastic bottom of the sensor (Fig. 2):
F1-F4 = SET-UP FOR FIXING IN CORNER
A-B = SET-UP FOR FIXING ON FLAT SURFACE
C-D = SET-UP FOR CABLE PASSING
Fix the plastic bottom to the wall with screws and anchor bolts being careful that
they do not touch the electronic board.
Refit the circuit onto the plastic bottom.
INSTALLATION WITH BRACKET
The complete user manuals of the brackets are available on the website
www.elkron.com.
TERMINAL BOARD DESCRIPTION
I
Inhibit input
- + 12V power
NC TAMP
NC contact
NC ALL
NC alarm relay contact
FIRST POWER-ON
When power is connected, the sensor will start an initialising step during which
the three LEDs will blink alternatively.
The sensor will start working after this step
(which lasts approximately 60 seconds).
In this mode, regardless of the state of the LED OFF jumper, the sensor will show
the microwave detections, the infrared detection and the alarm state to allow the
installer to check operation.
This condition will persist for 20 minutes.
The following will appear on the sensor after this time:
in LED ON mode (jumper on) alarms only by means of the blue LED;
in LED OFF mode (jumper NOT inserted) memories only.
Proceed with the walk test, as follows:
MW (Microwave)
Set the trimmer (range 0.5 - 15 m) according to the environment to be protected
and check the MW detections by means of the GREEN LED.
Note:
The MW range must be set to the minimum because microwaves can cross
walls and detect disturbances and movements outside the room to be protected..
INFRARED (PIR)
Apply the plastic front and with the LEDs off move in the area of pertinence of the
sensor checking PIR detection using the YELLOW LED.
FUNCTIONS
AUTOMATIC ECO
The sensor is provided with a special algorithm which reduces to the microwave
emissions to the minimum.
Without needing to connect the Inhibit input, the sensor determines whether the
system is on or off by monitoring the movements in the environment.
This allows to limit microwave emissions to the minimum when the system is off
and to avoid unnecessary radiations for the people present in the environment.
This advantage is achieved without losing detection sensitivity or false alarm
immunity.
LED OFF - Jumper off (on by default)
Deactivates the detection views maintaining the memory views enabled.
FUNCTIONS WITH INHIBIT INPUT
These functions are activated/deactivated by switching the system on and off.
With this regard:
12V on the INHIBIT input = system off
0V on the INHIBIT input = system on
REMOTE LED ENABLING - LED OFF REQUIRED CONDITION
The sensor is set to re-enable detected views when the system is switched off.
The views will be re-enabled at the first detection and will remain active for 30sec.
MEMORIES
The memory of the first alarm will be viewed when the system is switched off as
shown in TAB. 1 (MEMORY STATE VIEWS).
The memory will be reset when
the system is switched on again.
MEMORY DELAY FOR TIMED ENTRANCE
Exit time:
the alarms occurring during the first 30" from when the system is
switched on are deleted.
Entrance time:
the alarms occurring during the 30" before the system is switched
off are deleted.
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, URMET S.p.A. declares that the radio equipment type: DUAL
TECHNOLOGY DETECTOR DT15 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following
internet address: www.elkron.com.
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF
THE COUNCIL of 4 July 2012 on waste electrical and electronic
equipment (WEEE).
The symbol of the crossed-out wheeled bin on the product or on its
packaging indicates that this product must not be disposed of with your other
household waste.
Instead, it is your responsibility to dispose of your waste equipment by handing
it over to a designated collection point for the recycling of waste electrical and
electronic equipment. The separate collection and recycling of your waste
equipment at the time of disposal will help to conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment.
For more information about where you can drop off your waste equipment for
recycling, please contact your local city office, your household waste disposal
service or the shop where you purchased the product.
CARACTERISTIQUES TECHNIQUES
Tension nominale d’alimentation :.............. 12V +/- 3V
Absorption à 12 V : ................................ 8mA nom. 22mA maximum
Sensibilité micro-onde (MW) : ................... 0,5÷15m±20% (par
commutateur)
Fréquence : ................................................ 10,525 GHz
Puissance d'émission (EIRP) : ................... 8dBm
Portée : ...................................................... 15 m
Couverture MW : ........................................ 90° horizontale - 36° verticale
Couverture IR :........................................... 90°
Zones de détection : ................................. 18 faisceaux/4 plans creep
zone
Relais d'alarme : ........................................ 100mA / 24V
Pouvoir tamper anti-ouverture :.................. 100 mA / 30V
Temps de maintien en alarme ................... 3 s
Température de fonctionnement : .............. -10 ÷ +55
Humidité relative admissible : .................... 95%
MTBF théorique : ....................................... 120.000 heures
Dimensions (h x l x p) ................................ 107x61,5x43,5 mm
Poids : ........................................................ 110 g
Niveau de performances : .......................... EN50131-2-4, Degré 2,
CLASSE II
ACCESSOIRES EN OPTION
Rotules pour IR15 - DT15 - DT15AM (10 pcs.) Réf. 80SP1E00113 / Réf.
80SP1F00113
INSTRUCTIONS
Installer le détecteur sur des surfaces rigides, non exposées aux
vibrations, à une hauteur comprise entre 2 et 2,2 m en fonction des
diagrammes typiques de détection, de manière à ce que le détecteur
détecte les déplacements qui croisent la zone protégée et que le module
micro-onde tecte les mouvements en approche. Eviter de placer le
détecteur à proximité de sources de chaleur ou de l’exposer à la lumière
directe du soleil.
Eviter le réfléchissement de l'énergie électromagnétique sur de grandes
surfaces (par exemple, miroirs, parois métalliques, etc.).
Eviter de pointer le détecteur sur des lampes fluorescentes ou de le
placer à proximité de celles-ci.
Eviter de créer, du fait de meubles, d’étagères, etc., des zones invisibles
à l'intérieur de l’espace protégé, qui permettraient à un intrus de se
déplacer. Eviter la présence d'animaux dans la zone protégée.
En cas d’installations à des hauteurs supérieures à 2,1 m, il est conseillé
d'utiliser la rotule optionnelle, en inclinant le détecteur de manière à
adapter au mieux les champs de couverture aux nécessités effectives.
INSTALLATION SANS ROTULE
Pour déposer le capot du détecteur, ôter la vis de fermeture (si présente) et
appuyer sur l’ergot de fixation. Pour enlever le circuit imprimé, élargir l’une
des attaches E1-E2 (Fig. 2).
Attention : ne pas toucher le détecteur pyro-électrique avec les doigts
Fond en plastique du détecteur (Fig. 2) :
F1-F4 = PRE-PERÇAGE POUR LA FIXATION ANGULAIRE
A-B = PRE-PERÇAGE POUR LA FIXATION SUR SURFACE PLANE
C-D = PRE-PERÇAGE POUR LE PASSAGE DES CABLES
Fixer le fond en plastique à la paroi à l’aide des vis et des chevilles, en
veillant à ce que leurs têtes ne soient pas en contact avec la carte
électronique. Reposer le circuit sur le fond en plastique.
INSTALLATION AVEC ROTULE
Les manuels d'utilisation complets des rotules sont disponibles sur le site
www.elkron.com.
DESCRIPTION BOITE A BORNES
I Entrée Inhibit
- + Alimentation 12V
NC TAMP Contact N.F.
NC ALL Contact N.F. du relais d'alarme
PREMIERE ALIMENTATION
Une fois alimenté, le détecteur entre dans la phase d'initialisation, au cours
de laquelle les trois LED clignotent, puis restent allumées. Au terme de
cette phase (d’une durée d’environ 60 secondes), le détecteur est
opérationnel. Dans cette modalité, indépendamment de l’état du cavalier
LED OFF, le détecteur affichera les détections de la micro-onde, celles de
l’infrarouge et l’état d’Alarme pour permettre à l’installateur de vérifier le
fonctionnement. Cette condition perdure pendant 20 minutes.
Au bout de c délai, le détecteur affichera :
si LED ON (cavalier en place), uniquement les alarmes via la LED
bleue ;
Si LED OFF (cavalier NON en place), uniquement d’éventuelles
mémoires.
Pour le test de portée, procéder comme suit :
MW (Micro-onde)
Régler le trimmer (portée 0,5 - 15 mt) en fonction de la zone à protéger, en
vérifiant les détections de MW à travers la LED VERTE.
Note : la portée MW doit être réglée sur la valeur minimum nécessaire ; en
effet, les micro-ondes étant en mesure de passer à travers les murs, elles
peuvent détecter des perturbations ou des mouvements à l’extérieur du
local à protéger.
INFRAROUGE (PIR)
Appliquer la façade en plastique et, LED éteintes, se déplacer dans la zone
concernée, en vérifiant la détection du PIR à travers la LED JAUNE.
FONCTIONS
AUTOMATIC ECO
Le détecteur est doté d’un algorithme spécial qui minimise les émissions de
la Micro-onde. Sans nécessairement raccorder l’entrée Inhibit, le détecteur,
à travers le monitorage des mouvements dans l’espace, détermine si
l’installation est sous/hors tension. Cette condition lui permet de limiter au
maximum les émissions de Micro-onde lorsque l’installation est hors
tension, pour ne pas irradier inutilement les personnes présentes dans la
zone concernée. Cet avantage n’est pas obtenu au détriment de la
sensibilité de détection ou de l’immunité aux fausses alertes.
LED OFF - Cavalier désactivé (configuration d’usine : activé)
Il désactive les signalisations de détection, tout en maintenant habilitées
celles relatives aux mémoires.
FONCTIONS AVEC ENTREE INHIBIT
Ces fonctions sont activées/désactivées à travers la mise sous/hors tension
de l’installation. A ce propos, l‘on considère :
12V sur l’entrée INHIBIT = installation hors tension
0V sur l’entrée INHIBIT = installation sous tension
HABILITATION LED A DISTANCE - CONDITION REQUISE : LED OFF
Lors de la mise hors tension de l’installation, le détecteur se prépare pour
le rétablissement des signalisations de détection. Les signalisations seront
rétablies dès la première détection effectuée et elles demeureront actives
pendant 30 s.
MEMOIRES
Lors de la mise hors tension de l’installation, la mémoire de la première
alarme intervenue sera affichée, comme indiqué dans le TAB.1
(AFFICHAGES D’ETAT MEMOIRE). La mémoire sera réinitialisée lors de
la mise sous tension successive de l’installation.
DELAI DE MEMOIRE POUR L’UTILISATION D’ENTREES
TEMPORISEES
Temps de sortie : les alarmes qui surviennent au cours des 30 premières
secondes après l’activation de l’installation, sont effacées.
Temps d’entrée : les alarmes qui surviennent 30 secondes avant la
désactivation de l’installation, sont effacées.
DECLARATION UE DE CONFORMITE SIMPLIFIEE
Le soussigné, URMET S.p.A., déclare que l’équipement radioélectrique du
type DÉTECTEUR À DOUBLE TECHNOLOGIE DT15 est conforme à la
directive 2014/53/UE. Le texte complet de la déclaration UE de conformi
est disponible à l’adresse internet suivante: www.elkron.com.
LES BONS GESTES DE MISE AU REBUT DE CE PRODUIT (Déchets
d’équipements électriques et électroniques)
Ce symbole apposé sur le produit, ses accessoires ou sa
documentation indique que ni le produit, ni ses accessoires
électroniques usagés (chargeur, casque audio, câble USB,
etc.), ne peuvent être jetés avec les autres déchets ménagers.
La mise au rebut incontrôlée des déchets présentant des
risques environnementaux et de santé publique, veuillez séparer vos
produits et accessoires usagés des autres déchets. Vous favoriserez ainsi
le recyclage de la matière qui les compose dans le cadre d’un
développement durable.
D E RUS
SVK UK
TAB. 1
VISUALIZZAZIONI IN STATO
DI MEMORIA
ALLARME
VERDE
GIALLO
PIR+MW SPENTO ACCESO SPENTO
TAB. 1
MEMORY STATE VIE
WS
ALARM
GREEN
BLUE
YELLOW
PIR+MW OFF ON OFF
TAB. 1
AFFICHAGES D’ETAT MEMOIRE
ALARME
VERT
BLEU
JAUNE
PIR+MW ETEINT ALLUME ETEINT
RIVELATORE A DOPPIA
TECNOLOGIA
DUAL TECHNOLOGY
DETECTOR
DÉTECTEUR À DOUBLE
TECHNOLOGIE
COPERTURA
COVER
COUVERTURE
I
GB
FR
-
+
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elkron DT15 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elkron DT15 in de taal/talen: Duits, Engels, Frans, Italiaans, Portugees, Spaans als bijlage per email.

De handleiding is 0,38 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info