Add and Remove Devices
(NB: only required if adding a new thermostat. All items in the Wish 1, 2 & 3 packs are pre-bound)
To manually connect a miGenie thermostat, insert the batteries into the thermostat and wait for “Bind?” to be
displayed, press ( ) to select. You will also need to enter the binding process on the miGenie Controller, by entering
the Advanced Settings menu, then the Zone settings and select the Device manager option. In this screen select
the Add thermostat option to complete the binding process. To remove a miGenie Thermostat enter the Device
manager option in the miGenie controller using the same sequence detailed above. The option will now display
Remove Thermostat, select this option and the thermostat will be removed from the system.
To manually connect a miGenie gateway, press and hold the button on the rear of the gateway for more than 5
seconds, the LED will repeatedly flash red-yellow-green. You will also need to enter the binding process on the
miGenie Controller, by entering the Advanced Settings menu, then System settings, then Internet options. In this
screen select the Add gateway option to complete the binding process. To remove a miGenie Gateway enter the
Internet options menu in the miGenie controller using the same sequence detailed above. The menu will display
Remove gateway, select this option and the gateway will be removed from the system.
Technical Data
Step 7: Connection Charts
Step 8: Advanced Settings
Step 8: Advanced Settings
Feature Description Factory Pre-Set
Device manager Add, replace or remove RF room thermostats Pre-bound
Signal strength Displays the signal strength of the selected zone, if a miGenie thermostat is connected to the zone
Channel settings (within
Zone settings)
Customise the application type and associated control settings for zones following this
application type
Application type Selecting the application type pre-configures
the available zone information
Zone 1: Heating:
Zone 2: Hot Water
Zone 3: Heating
Zone 4: Unused
Control type
*Heating zones only
Select TPI or TP.
TPI = Use if the house usually reaches setpoint in ≤ 1 hour.
TP = Use if the house usually reaches setpoint in ≥ 1 hour.
TPI
Cycle rate (only when
control type is TPI or TP)
Select 3 cph (cycles per hour), 6 cph or 12 cph 6 cph
Frost temperature Disable frost protection or set between 3-10°C 5°C
Valve protection The output will be activated for the specified time (in minutes). This
will happen weekly, related to the last action of the output. Select 0
to 10 minutes.
0 mins (Off)
Feature Description Factory Pre-Set
Advanced settings
! CAUTION! These settings should only be modified by a qualified person. They can influence the
safety and the proper functioning of the system
System settings These are settings applicable to the system controller unit, global settings
for bound nodes and internet connection settings
Backlight miGenie controller options are:
On with timeout, Always on, Always off
miGenie thermostat options are:
On with timeout, always off
On with timeout
Lock settings Enable or disable the screen lock for the miGenie controller. To lock:
enter a 3 digit code for protection. To unlock: enter the 3 digit code
000
Master code 401
Product Information View product details for devices in the system e.g. part number, firmware version, etc.
Signal strength Informs about the current signal strength of the products connected to the system
Internet options Sub-menu relating to the connection of an internet gateway – enables
a gateway to be added, replaced or removed with an indication of signal strength.
System reset Will reset all settings to factory pre-sets
Zone settings Customise each zone according to personal preferences
These are setting which will be applied to a connected thermostat
Select zone Select the zone for the following actions
Rename zone To rename an existing zone Heating, H Water, LivRoom
Edit schedule Update the schedule for the zone
Zone setup Contains detailed zone setup values – see below for descriptions
Minimum
temperature
The minimum set temperature that can be set
for the zone
5°C
Maximum
temperature
The maximum set temperature that can be set
for the zone
30°C
Eco
temperature
Temperature used for energy saving events
e.g. during the night
16°C
Comfort
temperature
Temperature used for comfort events
e.g. during the day
21°C
Offset
temperature
Adjust the displayed temperature to personal needs 0°C
! IMPORTANT:
Always switch off the mains before removing
the miGenie Controller – and never fit it to a live
wall-plate!
Arrowed numbers relate to the junction box.
* Consult boiler handbook for details of pump
overrun wiring.
Make the wiring connections, as above, for the
appropriate system. For surface wiring, snap out the
cable entry strip on the bottom edge of the wall-plate.
miGenie controllers are double-insulated and need
no earth connection, but an earthing continuity (loop)
terminal is provided for convenience.
After wiring, clip on the unit and tighten the securing
screws. Check the mains input has a 3A fuse, and switch
on the mains.
Biflo system: Model T724R Twinzone system: Model T724R
From the Home screen, select
Settings, then Advanced settings
as shown.
From here you can edit the assigned zones, rename them if required
and check the Signal strength.
Client Invensys File Name 7549 Invensys miGenie Instructions 06490211001 IssC
Artworker -
Proof Stage
PRINT
Finished Size 420x297mm
Creative Director Mike Lane Artwork % 100%
Modification Date 07/09/15 4:16PM Bleed 3mm
miGenie Controller
miGenie Controller
3 Zone system: Model T744R
miGenie Controller
Select a name from the list or
select 'Custom zone name' to
create a new zone name.
miGenie controller miGenie thermostat miGenie gateway
Power Supply 230V a.c. +10% -10% 50Hz 2 X 1.5V IEC LR6(AA) alkaline
batteries
5V d.c. 1A USB Micro-B
Switch Rating 2 (1) A 230V a.c. each switch N/A
Wiring Fixed wiring only, to comply with
current IET regulations (BS7671)
No wiring required
Battery life N/A 2 years typical N/A
Ambient Temperature
Operating: 0º to 45ºC (miGenie controller 3 / 4 channel 0º to 40ºC)
Storage: -20ºC to 5C
Ambient humidity
(non condensing)
Operating 25% to 90%
Storage 15% to 95%
Temperature Range 5 ºC - 30 ºC N/A
Control Accuracy <0.6ºC at 4º / hour N/A
Timing resolution 1 minute N/A
Temperature resolution 0.5°C N/A
Ball Pressure Test
Temperature
75ºC
Pollution Degree 2
Energy Class IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013) N/A
Software Class A
Without Mains Power Display: blank; Time: always kept
Program times: always preserved
N/A
Rated Impulse Voltage 2.5kV N/A
Radio Frequency 868.3MHz (Bi-directional communication)
Radio Signal Range 30m typically. The range may be affected by the composition / density and the number
of walls between the miGenie products
Mounting Industry standard wall plate Wall bracket or table stand Table top
Relevant EC Directives: 2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic Compatibility Directive
1999/5/EC R&TTE Directive
2013/56/EU Battery Directive
2011/65/EU RoHS Directive
Applied Standards: EN60730-1; EN60730-2-7; EN60730-2-9
EN 300 220-2; EN 301 489-3
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Drayton miGenie Wish 1 - T714R bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Drayton miGenie Wish 1 - T714R in de taal/talen: Engels als bijlage per email.

De handleiding is 3,02 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Drayton miGenie Wish 1 - T714R

Drayton miGenie Wish 1 - T714R Snelstart handleiding - English - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info